Literature DB >> 21431459

[Challenges for computed tomography of overweight patients].

F Bamberg1, R Marcus, M Petersilka, K Nikolaou, C R Becker, M F Reiser, T Johnson.   

Abstract

In morbidly obese patients, computed tomography frequently represents the only viable option for non-invasive imaging diagnostics. The aim of this study was to analyze the weight limits, dose and image quality with standard CT scanners and to determine the diagnostic value and dose with a dual source XXL mode.A total of 15 patients (average body weight 189.6 ± 42 kg) were retrospectively identified who had been examined with the XXL mode. Of these patients 7 (average body weight 176.4 ± 56 kg) had been examined using both the XXL and standard protocols allowing for an intraindividual comparison in this subcollective. Additionally 14 patients weighing between 90 and 150 kg (average 106.1 ± 19 kg) examined with standard protocols were included as references. Dose, image noise and subjectively assessed image quality (rating scale 1-4) were determined. Additionally, a large abdomen phantom of 48 cm diameter was examined with both protocols at equivalent tube current-time product in order to compare the dose efficiency.The patient groups differed significantly in dose (CTDI(vol) XXL 72.9 ± 23 versus standard 16.7 ± 11 mGy; intraindividual 64.1 ± 20 versus 27.0 ± 15 mGy). The image noise was generally somewhat higher in the XXL group but significantly lower in the intraindividual comparison (liver 24.2 ± 14 HU versus 36.3 ± 20 HU; p = 0.03; fat 15.5 ± 8 HU versus 26.2 ± 12 HU; p=0.02). With ratings of 1.9 ± 0.7 and 1.8 ± 0.7 image quality did not differ significantly in general, whereas there was a clear difference in the intraindividual comparison (1.8 ± 0.8 versus 3.0 ± 1.2) and only the XXL protocol achieved diagnostic quality in all cases, while 43% of the examinations with the standard protocol were rated as non-diagnostic. The quantification of dose efficiency in the phantom scans yielded no significant difference between the protocols.Up to 150 kg body weight, CT can be performed with the standard technique at 120 kVp with tube current modulation. In larger patients diagnostic image quality can only be achieved reliably with the dual source XXL mode, although at considerably increased calculated dose. However, standard conversion factors yield false high values so that the estimation of the biologically relevant equivalent dose is very difficult.

Entities:  

Mesh:

Year:  2011        PMID: 21431459     DOI: 10.1007/s00117-010-2087-5

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  9 in total

1.  Focal iodine defects on color-coded iodine perfusion maps of dual-energy pulmonary CT angiography images: a potential diagnostic pitfall.

Authors:  Mi-Jin Kang; Chang Min Park; Chang-Hyun Lee; Jin Mo Goo; Hyun Ju Lee
Journal:  AJR Am J Roentgenol       Date:  2010-11       Impact factor: 3.959

2.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

3.  Converting dose-length product to effective dose at CT.

Authors:  Walter Huda; Kent M Ogden; Mohammad R Khorasani
Journal:  Radiology       Date:  2008-09       Impact factor: 11.105

4.  Obesity and medical imaging challenges.

Authors:  April Reynolds
Journal:  Radiol Technol       Date:  2011 Jan-Feb

5.  Strategies for scatter correction in dual source CT.

Authors:  M Petersilka; K Stierstorfer; H Bruder; T Flohr
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

6.  A comparison of the prevalence of the metabolic syndrome in the United States (US) and Korea in young adults aged 20 to 39 years.

Authors:  Jinkyung Park; Jason A Mendoza; Carol E O'Neil; David C Hilmers; Yan Liu; Theresa A Nicklas
Journal:  Asia Pac J Clin Nutr       Date:  2008       Impact factor: 1.662

7.  The challenge of CT and MRI imaging of obese individuals who present to the emergency department: a national survey.

Authors:  Adit A Ginde; Anthony Foianini; Daniel M Renner; Morgan Valley; Carlos A Camargo
Journal:  Obesity (Silver Spring)       Date:  2008-09-11       Impact factor: 5.002

Review 8.  Technical principles of dual source CT.

Authors:  Martin Petersilka; Herbert Bruder; Bernhard Krauss; Karl Stierstorfer; Thomas G Flohr
Journal:  Eur J Radiol       Date:  2008-10-07       Impact factor: 3.528

9.  Epidemiology of abdominal obesity among adolescents from a Brazilian State Capital.

Authors:  Diego Augusto Santos Silva; Andreia Pelegrini; João Marcos Ferreira de Lima E Silva; Edio Luiz Petroski
Journal:  J Korean Med Sci       Date:  2010-12-22       Impact factor: 2.153

  9 in total
  1 in total

Review 1.  Dual energy CT in clinical routine: how it works and how it adds value.

Authors:  Aaron D Sodickson; Abhishek Keraliya; Bryan Czakowski; Andrew Primak; Jeremy Wortman; Jennifer W Uyeda
Journal:  Emerg Radiol       Date:  2020-06-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.