Literature DB >> 21426402

Attachment systems for implant overdenture: influence of implant inclination on retentive and lateral forces.

Tsung-Chieh Yang1, Yoshinobu Maeda, Tomoya Gonda, Sunny Kotecha.   

Abstract

OBJECTIVE: To evaluate the retentive force and lateral force of an implant with various types of attachments for overdentures in relation to implant inclination.
MATERIAL AND METHODS: An implant (3.75 × 13 mm) was embedded into an acrylic resin block, simulating the edentulous ridge. Four different attachment systems were used, including: (1) Locator black and blue, (2) a ball attachment, (3) a flat-type magnetic attachment and (4) a self-adjusting magnetic attachment, which has vertical and rotational movement. All of the attachments were under a constant dislodging force with an angle of the implant at 0°, 15°, 30° and 45°, and the experiments were repeated 10 times using a universal testing machine to measure the retentive force. The lateral force to the implant was measured by strain gauges attached on the implant surface. Statistical analysis was performed by multiple comparisons with Bonferroni's correction. P<0.05 was considered statistically significant.
RESULTS: At 0°, the significantly highest retentive force was observed in the Locator blue, followed by the Locator black, ball, flat-type and self-adjusting magnetic attachments. The Locator blue and ball attachment maintained the retentive force until a 30° inclination; however, the lateral force increased significantly, especially with the ball attachment. The retentive force of the magnetic attachment was significantly lower at 0°, as well as the lateral force in the self-adjusting magnetic attachment.
CONCLUSION: Within the limitations of this study, we conclude that the retentive force decreases with an increase in implant inclination, whereas the lateral force increases, except for in magnetic attachments.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21426402     DOI: 10.1111/j.1600-0501.2010.02137.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  11 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  Retentive characteristics of a vinylpolysiloxane overdenture attachment system.

Authors:  Ramona Schweyen; Florian Beuer; Christian Arnold; Jeremias Hey
Journal:  Clin Oral Investig       Date:  2014-08-22       Impact factor: 3.573

Review 3.  Factors Affecting the Attractive Force of Dental Magnetic Attachment: A Literature Review for Guiding Dentists in Clinical Application.

Authors:  An-Nissa Kusumadewi; Lisda Damayanti
Journal:  Int J Dent       Date:  2022-06-14

4.  Effects of type of magnet attachment and implant angulation in two implant overdenture models.

Authors:  So-Yeon Song; Kyeong-Hwan Kang; Jeong-Yol Lee; Sang-Wan Shin
Journal:  J Adv Prosthodont       Date:  2020-02-20       Impact factor: 1.904

5.  Clinical outcomes of implant-retained mandibular overdentures using the bar and magnetic attachment systems: an up to 5-year retrospective study.

Authors:  Huan Zhou; Yang Jiao; Chu-Fan Ma; Chao Wang; San-Jun Zhao; Min Tian; Franklin R Tay; Ji-Hua Chen
Journal:  Ann Transl Med       Date:  2020-11

Review 6.  Evaluation of Retention, Wear, and Maintenance of Attachment Systems for Single- or Two-Implant-Retained Mandibular Overdentures: A Systematic Review.

Authors:  Raphaël Wakam; Aurélie Benoit; Kwamivi Bernardin Mawussi; Caroline Gorin
Journal:  Materials (Basel)       Date:  2022-03-04       Impact factor: 3.623

7.  Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial.

Authors:  M Y Sharaf; Asharaf Eskander; Mohamed Afify Afify
Journal:  Int J Dent       Date:  2022-02-28

8.  An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures.

Authors:  Tejomaya Shastry; N M Anupama; Shilpa Shetty; M Nalinakshamma
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

9.  Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study.

Authors:  Moustafa Abdou Elsyad; Fathi Abo Setta; Ahmed Samir Khirallah
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

10.  In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®.

Authors:  Nieves Mínguez-Tomás; Jorge Alonso-Pérez-Barquero; Lucía Fernández-Estevan; Ángel Vicente-Escuder; Eduardo J Selva-Otaolaurruchi
Journal:  J Clin Exp Dent       Date:  2018-07-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.