Literature DB >> 21414747

Cup size and risk of dislocation after primary total hip arthroplasty.

Robin Peter1, Anne Lübbeke, Richard Stern, Pierre Hoffmeyer.   

Abstract

We evaluated the relationship between cup diameter and dislocation risk in patients undergoing primary total hip arthroplasty (THA) with a 28-mm head. There were 50 dislocations, 28 of which occurred in 2221 (1.3%) THAs with a cup diameter smaller than 56 mm and 22 in 513 (4.3%) with a cup diameter of 56 mm or larger. Dislocation risk varied between 0.6% and 2.4% in the smaller cup group and between 4.1% and 5.2% in the larger cup group. The risk was substantially higher in the large cup group (unadjusted odds ratio, 3.5; 95% confidence interval, 2.0-6.2). Multivariable logistic regression revealed an adjusted odds ratio of 2.4 (95% confidence interval, 1.2-4.9). Patients with THA (28-mm head) had more than twice the risk of dislocation with cup size of 56 mm or higher compared to patients with smaller cups.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21414747     DOI: 10.1016/j.arth.2010.11.015

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  12 in total

1.  A critical analysis of radiographic factors in patients who develop dislocation after elective primary total hip arthroplasty.

Authors:  Marion Opperer; Yuo-yu Lee; Francisco Nally; Alvaro Blanes Perez; Kaveh Goudarz-Mehdikhani; Alejandro Gonzalez Della Valle
Journal:  Int Orthop       Date:  2015-10-27       Impact factor: 3.075

2.  MyHip: supporting planning and surgical guidance for a better total hip arthroplasty : A pilot study.

Authors:  Jérôme Schmid; Christophe Chênes; Sylvain Chagué; Pierre Hoffmeyer; Panayiotis Christofilopoulos; Massimiliano Bernardoni; Caecilia Charbonnier
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-01       Impact factor: 2.924

3.  What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position.

Authors:  Matthew P Abdel; Philipp von Roth; Matthew T Jennings; Arlen D Hanssen; Mark W Pagnano
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

4.  Using nonlinear finite element models to analyse stress distribution during subluxation and torque required for dislocation of newly developed total hip structure after prosthetic impingement.

Authors:  Wei-Min Chi; Chien-Chung Lin; Ying-Jui Ho; Hsiao-Che Lin; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2017-07-01       Impact factor: 2.602

Review 5.  Biomechanical concept and clinical outcome of dual mobility cups.

Authors:  Aron Grazioli; Eugene Teow Hin Ek; Hannes Andreas Rüdiger
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

6.  Low dislocation rates with the use of patient specific "Safe zones" in total hip arthroplasty.

Authors:  Abhinav K Sharma; Zlatan Cizmic; Douglas A Dennis; Stefan W Kreuzer; Michael A Miranda; Jonathan M Vigdorchik
Journal:  J Orthop       Date:  2021-08-21

7.  Compared learning curves of the direct anterior and anterolateral approach for minimally invasive hip replacement.

Authors:  Johannes C Reichert; Georgi I Wassilew; Eberhard von Rottkay; Ulrich Noeth
Journal:  Orthop Rev (Pavia)       Date:  2022-08-25

8.  A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk.

Authors:  Jacques H Caton; Jean Louis Prudhon; André Ferreira; Thierry Aslanian; Régis Verdier
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

9.  Anterior total hip arthroplasty using a metaphyseal bone-sparing stem: component alignment and early complications.

Authors:  Mohammed M Ahmed; Thomas J Otto; Berton R Moed
Journal:  J Orthop Surg Res       Date:  2016-04-22       Impact factor: 2.359

Review 10.  Causes of and treatment options for dislocation following total hip arthroplasty.

Authors:  Yian Lu; Haijun Xiao; Feng Xue
Journal:  Exp Ther Med       Date:  2019-07-03       Impact factor: 2.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.