BACKGROUND: Computer numeric controlled (CNC) milling was proven to be predictable method to fabricate accurately fitting implant titanium frameworks. However, no data are available regarding the fit of CNC-milled implant zirconia frameworks.
PURPOSE: To compare the precision of fit of implant frameworks milled from titanium and zirconia and relate it to peri-implant strain development after framework fixation.
MATERIALS AND METHODS: A partially edentulous epoxy resin models received two Branemark implants in the areas of the lower left second premolar and second molar. From this model, 10 identical frameworks were fabricated by mean of CNC milling. Half of them were made from titanium and the other half from zirconia. Strain gauges were mounted close to the implants to qualitatively and quantitatively assess strain development as a result of framework fitting. In addition, the fit of the framework implant interface was measured using an optical microscope, when only one screw was tightened (passive fit) and when all screws were tightened (vertical fit). The data was statistically analyzed using the Mann-Whitney test.
RESULTS: All frameworks produced measurable amounts of peri-implant strain. The zirconia frameworks produced significantly less strain than titanium. Combining the qualitative and quantitative information indicates that the implants were under vertical displacement rather than horizontal. The vertical fit was similar for zirconia (3.7 µm) and titanium (3.6 µm) frameworks; however, the zirconia frameworks exhibited a significantly finer passive fit (5.5 µm) than titanium frameworks (13.6 µm).
CONCLUSIONS: CNC milling produced zirconia and titanium frameworks with high accuracy. The difference between the two materials in terms of fit is expected to be of minimal clinical significance. The strain developed around the implants was more related to the framework fit rather than framework material.
© 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21414138     DOI: 10.1111/j.1708-8208.2010.00334.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  11 in total

Review 1.  The management of severe hypodontia. Part 2: bone augmentation and the provision of implant supported prostheses.

Authors:  K Durey; L Carter; M Chan
Journal:  Br Dent J       Date:  2014-01       Impact factor: 1.626

2.  [Effect of materials and superstructure designs on the passive fit of implant-supported fixed prostheses].

Authors:  Shan Song; Zheng Zheng; Li-Yuan Yang; Xu Gao
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2019-02-01

3.  Interbody Spacer Material Properties and Design Conformity for Reducing Subsidence During Lumbar Interbody Fusion.

Authors:  Lillian S Chatham; Vikas V Patel; Christopher M Yakacki; R Dana Carpenter
Journal:  J Biomech Eng       Date:  2017-05-01       Impact factor: 2.097

4.  Analysis of fit on implants of chrome cobalt versus titanium frameworks made by cad / cam milling.

Authors:  Begoña Oteiza-Galdón; Amparo Martínez-González; Ángel-Vicente Escuder
Journal:  J Clin Exp Dent       Date:  2020-10-01

5.  Clinical management of implant prostheses in patients with bruxism.

Authors:  Osamu Komiyama; Frank Lobbezoo; Antoon De Laat; Takashi Iida; Tsuyoshi Kitagawa; Hiroshi Murakami; Takao Kato; Misao Kawara
Journal:  Int J Biomater       Date:  2012-06-04

6.  Dimensional Changes of 3-Unit Implant-Supported Zirconia Frameworks of Two CAD/CAM Systems from Scanning to Sintering.

Authors:  Marzieh Alikhasi; Narges Ameri; Hakimeh Siadat; Ahmad Reza Shamshiri; Mohammadreza Nejati
Journal:  Front Dent       Date:  2019-06-29

7.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

8.  Rationale for the use of CAD/CAM technology in implant prosthodontics.

Authors:  Jaafar Abduo; Karl Lyons
Journal:  Int J Dent       Date:  2013-04-16

Review 9.  Trends in computer-aided manufacturing in prosthodontics: a review of the available streams.

Authors:  Jaafar Abduo; Karl Lyons; Mohammed Bennamoun
Journal:  Int J Dent       Date:  2014-04-08

10.  Fit of cobalt-chromium implant frameworks before and after ceramic veneering in comparison with CNC-milled titanium frameworks.

Authors:  Per Svanborg; Victoria Stenport; Alf Eliasson
Journal:  Clin Exp Dent Res       Date:  2015-10-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.