Two-dimensional radial acquisition technique with density adaption in sodium MRI.

Simon Konstandin1, Armin M Nagel, Patrick M Heiler, Lothar R Schad.   

Abstract

Conventional 2D radial projections suffer from losses in signal-to-noise ratio efficiency because of the nonuniform k-space sampling. In this study, a 2D projection reconstruction method with variable gradient amplitudes is presented to cover the k-space uniformly. The gradient is designed to keep the average sampling density constant. By this, signal-to-noise ratio is increased, and the linear form of the radial trajectory is kept. The simple gradient design and low hardware requirements in respect of slew rate allow an easy implementation at MR scanners. Measurements with the density-adapted 2D radial trajectory were compared with the conventional projection reconstruction method. It is demonstrated that the density-adapted 2D radial trajectory technique provides higher signal-to-noise ratio (up to 28% in brain tissue), less blurring, and fewer artifacts in the presence of magnetic field inhomogeneities than imaging with the conventional 2D radial trajectory scheme. The presented sequence is well-suited for electrocardiographically gated sodium heart MRI and other applications with short relaxation times.
Copyright © 2010 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2010        PMID: 21413073     DOI: 10.1002/mrm.22684

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

Review 1.  Measurement techniques for magnetic resonance imaging of fast relaxing nuclei.

Authors:  Simon Konstandin; Armin M Nagel
Journal:  MAGMA       Date:  2013-07-24       Impact factor: 2.310

2.  Optimized three-dimensional sodium imaging of the human heart on a clinical 3T scanner.

Authors:  Neville D Gai; Carlos Rochitte; Marcelo S Nacif; David A Bluemke
Journal:  Magn Reson Med       Date:  2014-03-17       Impact factor: 4.668

Review 3.  Quantitative sodium MR imaging: A review of its evolving role in medicine.

Authors:  Keith R Thulborn
Journal:  Neuroimage       Date:  2016-11-24       Impact factor: 6.556

4.  Variability of CubeQuant T1ρ, quantitative DESS T2, and cones sodium MRI in knee cartilage.

Authors:  C D Jordan; E J McWalter; U D Monu; R D Watkins; W Chen; N K Bangerter; B A Hargreaves; G E Gold
Journal:  Osteoarthritis Cartilage       Date:  2014-10       Impact factor: 6.576

5.  Sodium MRI and the assessment of irreversible tissue damage during hyper-acute stroke.

Authors:  Fernando E Boada; Yongxian Qian; Edwin Nemoto; Tudor Jovin; Charles Jungreis; S C Jones; Jonathan Weimer; Vincent Lee
Journal:  Transl Stroke Res       Date:  2012-05-04       Impact factor: 6.829

6.  Optimized 3D ultrashort echo time pulmonary MRI.

Authors:  Kevin M Johnson; Sean B Fain; Mark L Schiebler; Scott Nagle
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

7.  Chlorine and sodium chemical shift imaging during acute stroke in a rat model at 9.4 Tesla.

Authors:  Sebastian Baier; Philipp Krämer; Saskia Grudzenski; Marc Fatar; Stefan Kirsch; Lothar R Schad
Journal:  MAGMA       Date:  2013-08-10       Impact factor: 2.310

8.  Exploring a new method for quantitative sodium MRI in the human upper leg with a surface coil and symmetrically arranged reference phantoms.

Authors:  Bastien Milani; Jean Delacoste; Michel Burnier; Menno Pruijm
Journal:  Quant Imaging Med Surg       Date:  2019-06
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.