Literature DB >> 21397334

Comparison of automated analysis of Cirrus HD OCT spectral-domain optical coherence tomography with stereo photographs of the optic disc.

Ashish Sharma1, Jonathan D Oakley, Joyce C Schiffman, Donald L Budenz, Douglas R Anderson.   

Abstract

OBJECTIVE: To evaluate a new automated analysis of optic disc images obtained by spectral-domain optical coherence tomography (SD OCT). Areas of the optic disc, cup, and neural rim in SD OCT images were compared with these areas from stereoscopic photographs to represent the current traditional optic nerve evaluation. The repeatability of measurements by each method was determined and compared.
DESIGN: Evaluation of diagnostic technology. PARTICIPANTS: One hundred nineteen healthy eyes, 23 eyes with glaucoma, and 7 glaucoma suspect eyes.
METHODS: Optic disc and cup margins were traced from stereoscopic photographs by 3 individuals independently. Optic disc margins and rim widths were determined automatically in SD OCT. A subset of photographs was examined and traced a second time, and duplicate SD OCT images also were analyzed. MAIN OUTCOME MEASURES: Agreement among photograph readers, between duplicate readings, and between SD OCT and photographs were quantified by the intraclass correlation coefficient (ICC), by the root mean square, and by the standard deviation of the differences.
RESULTS: Optic disc areas tended to be slightly larger when judged in photographs than by SD OCT, whereas cup areas were similar. Cup and optic disc areas showed good correlation (0.8) between the average photographic reading and SD OCT, but only fair correlation of rim areas (0.4). The SD OCT was highly reproducible (ICC, 0.96-0.99). Each reader also was consistent with himself on duplicate readings of 21 photographs (ICC, 0.80-0.88 for rim area and 0.95-0.98 for all other measurements), but reproducibility was not as good as SD OCT. Measurements derived from SD OCT did not differ from photographic readings more than the readings of photographs by different readers differed from each other.
CONCLUSIONS: Designation of the cup and optic disc boundaries by an automated analysis of SD OCT was within the range of variable designations by different readers from color stereoscopic photographs, but use of different landmarks typically made the designation of the optic disc size somewhat smaller in the automated analysis. There was better repeatability among measurements from SD OCT than from among readers of photographs. The repeatability of automated measurement of SD OCT images is promising for use both in diagnosis and in monitoring of progression.
Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21397334      PMCID: PMC3129482          DOI: 10.1016/j.ophtha.2010.12.008

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  30 in total

1.  Agreement between optical coherence tomography and digital stereophotography in vertical cup-to-disc ratio measurement.

Authors:  Giacomo Savini; Edgar M Espana; Ana Carolina Acosta; Michele Carbonelli; Costantino Bellusci; Piero Barboni
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-10-29       Impact factor: 3.117

2.  Automated segmentation of the optic disc from stereo color photographs using physiologically plausible features.

Authors:  Michael D Abràmoff; Wallace L M Alward; Emily C Greenlee; Lesya Shuba; Chan Y Kim; John H Fingert; Young H Kwon
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-04       Impact factor: 4.799

3.  Automated segmentation of the cup and rim from spectral domain OCT of the optic nerve head.

Authors:  Michael D Abràmoff; Kyungmoo Lee; Meindert Niemeijer; Wallace L M Alward; Emily C Greenlee; Mona K Garvin; Milan Sonka; Young H Kwon
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-07-15       Impact factor: 4.799

4.  Spectral domain optical coherence tomography for glaucoma (an AOS thesis).

Authors:  Joel S Schuman
Journal:  Trans Am Ophthalmol Soc       Date:  2008

5.  Comparison of retinal nerve fiber layer measurements using time domain and spectral domain optical coherent tomography.

Authors:  O'Rese J Knight; Robert T Chang; William J Feuer; Donald L Budenz
Journal:  Ophthalmology       Date:  2009-04-22       Impact factor: 12.079

6.  Detection of optic nerve head neural canal opening within histomorphometric and spectral domain optical coherence tomography data sets.

Authors:  Nicholas G Strouthidis; Hongli Yang; Brad Fortune; J Crawford Downs; Claude F Burgoyne
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-08-08       Impact factor: 4.799

7.  Measurement of optic nerve head parameters: comparison of optical coherence tomography with digital planimetry.

Authors:  Chameen Samarawickrama; Amy Pai; Son C Huynh; George Burlutsky; Jost B Jonas; Paul Mitchell
Journal:  J Glaucoma       Date:  2009 Oct-Nov       Impact factor: 2.503

8.  Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes.

Authors:  Donald L Budenz; Marie-Josée Fredette; William J Feuer; Douglas R Anderson
Journal:  Ophthalmology       Date:  2007-08-13       Impact factor: 12.079

9.  Variance owing to observer, repeat imaging, and fundus camera type on cup-to-disc ratio estimates by stereo planimetry.

Authors:  Young H Kwon; Michael Adix; M Bridget Zimmerman; Scott Piette; Emily C Greenlee; Wallace L M Alward; Michael D Abràmoff
Journal:  J Glaucoma       Date:  2009 Apr-May       Impact factor: 2.503

10.  Clinical assessment of stereoscopic optic disc photographs for glaucoma: the European Optic Disc Assessment Trial.

Authors:  Nicolaas J Reus; Hans G Lemij; David F Garway-Heath; P Juhani Airaksinen; Alfonso Anton; Alain M Bron; Christoph Faschinger; Gábor Holló; Michele Iester; Jost B Jonas; Andrea Mistlberger; Fotis Topouzis; Thierry G Zeyen
Journal:  Ophthalmology       Date:  2010-01-04       Impact factor: 12.079

View more
  16 in total

1.  Influence of clinically invisible, but optical coherence tomography detected, optic disc margin anatomy on neuroretinal rim evaluation.

Authors:  Alexandre S C Reis; Neil O'Leary; Hongli Yang; Glen P Sharpe; Marcelo T Nicolela; Claude F Burgoyne; Balwantray C Chauhan
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-04-18       Impact factor: 4.799

2.  Quantifying structures in the ocular fundus.

Authors:  Douglas R Anderson; Claude Burgoyne
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-07-09       Impact factor: 4.799

3.  Quantitative Analysis of Ellipsoid Zone in Acute Posterior Multifocal Placoid Pigment Epitheliopathy.

Authors:  Andrew W Browne; Waseem Ansari; Ming Hu; Kimberly Baynes; Careen Y Lowder; Justis P Ehlers; Sunil K Srivastava
Journal:  J Vitreoretin Dis       Date:  2020-02-11

4.  Combination of optic disc rim area and retinal nerve fiber layer thickness for early glaucoma detection by using spectral domain OCT.

Authors:  Min Hee Suh; Sun Kwon Kim; Ki Ho Park; Dong Myung Kim; Seok Hwan Kim; Hee Chan Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-09-25       Impact factor: 3.117

Review 5.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

6.  Positional independence of optic nerve head and retinal nerve fiber layer thickness measurements with spectral-domain optical coherence tomography.

Authors:  Kaweh Mansouri; John H K Liu; Ali Tafreshi; Felipe A Medeiros; Robert N Weinreb
Journal:  Am J Ophthalmol       Date:  2012-07-19       Impact factor: 5.258

7.  Clinicopathologic correlation of disc and peripapillary region using SD-OCT.

Authors:  Eric J Sigler; Kristy G Mascarenhas; James C Tsai; Nils A Loewen
Journal:  Optom Vis Sci       Date:  2013-01       Impact factor: 1.973

8.  Glaucoma diagnosis optic disc analysis comparing Cirrus spectral domain optical coherence tomography and Heidelberg retina tomograph II.

Authors:  Hye Young Shin; Hae-Young Lopilly Park; Kyoung In Jung; Chan Kee Park
Journal:  Jpn J Ophthalmol       Date:  2012-10-27       Impact factor: 2.447

9.  Glaucoma Diagnosis and Monitoring Using Advanced Imaging Technologies.

Authors:  Mitra Sehi; Shawn M Iverson
Journal:  US Ophthalmic Rev       Date:  2013

10.  Variance reduction in a dataset of normal macular ganglion cell plus inner plexiform layer thickness maps with application to glaucoma diagnosis.

Authors:  Robert W Knighton; Giovanni Gregori; Donald L Budenz
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-06-14       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.