Cranial base foramen location accuracy and reliability in cone-beam computerized tomography.

Manuel O Lagravère1, Jillian M Gordon, Carlos Flores-Mir, Jason Carey, Giseon Heo, Paul W Major.   

Abstract

INTRODUCTION: The purpose of this study was to evaluate the reliability and accuracy in locating several different foramina in the cranial base by using cone-beam computerized tomography (CBCT) images for future use in establishing reference coordinate systems.
METHODS: CBCT images from 10 dry skulls were taken with and without the foramina ovale, spinosum, and rotundum, and the hypoglossal canals filled with radiopaque gutta-percha (gold standard). Three evaluators identified the foramen landmarks in the CBCT images without gutta-percha. Mean differences and main researcher intraexaminer and interexaminer reliability were measured by using intraclass correlation coefficients for all landmark coordinates. Descriptive statistics were calculated with respect to the landmark coordinates and distances to the reference points.
RESULTS: Intraexaminer and interexaminer reliability values for the x-, y-, and z-coordinates for all landmarks were greater than 0.9 with the exception of 4 (of 72) points that still had acceptable interexaminer reliability (>0.75). Mean measurement error differences obtained in the principal investigator's trials were primarily less than 0.5 mm. When comparing the mean distance differences of the same examiner and between the 3 examiners with the gold standard, the highest difference obtained was 1.3 mm.
CONCLUSIONS: Foramina spinosum, ovale, and rotundum, and the hypoglossal canal all provided high intraexaminer reliability and accuracy, and can be considered acceptable landmarks to use in establishing reference coordinate systems for future 3-dimensional superimposition analysis.
Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21392663     DOI: 10.1016/j.ajodo.2009.06.027

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  9 in total

1.  Reliability of 3D dental and skeletal landmarks on CBCT images.

Authors:  Joorok Park; Sheldon Baumrind; Sean Curry; Sean K Carlson; Robert L Boyd; Heesoo Oh
Journal:  Angle Orthod       Date:  2019-03-18       Impact factor: 2.079

2.  Development and Validation of Novel Three-Dimensional Craniofacial Landmarks on Cone-Beam Computed Tomography Scans.

Authors:  Denise K Liberton; Payal Verma; Anthony Contratto; Janice S Lee
Journal:  J Craniofac Surg       Date:  2019-10       Impact factor: 1.046

3.  Proposal of new upper airway margins in children assessed by CBCT.

Authors:  S Anandarajah; Y Abdalla; R Dudhia; L Sonnesen
Journal:  Dentomaxillofac Radiol       Date:  2015-03-25       Impact factor: 2.419

4.  Multiobjective optimization framework for landmark measurement error correction in three-dimensional cephalometric tomography.

Authors:  A DeCesare; M Secanell; M O Lagravère; J Carey
Journal:  Dentomaxillofac Radiol       Date:  2013-05-02       Impact factor: 2.419

5.  Reliability of anatomic structures as landmarks in three-dimensional cephalometric analysis using CBCT.

Authors:  Pegah Naji; Noura A Alsufyani; Manuel O Lagravère
Journal:  Angle Orthod       Date:  2013-12-23       Impact factor: 2.079

6.  Visibility of sutures of the orbit and periorbital region using multidetector computed tomography.

Authors:  Hubert Gufler; Markus Preiß; Sabrina Koesling
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

7.  Application of the foramina of the trigeminal nerve as landmarks for analysis of craniofacial morphology.

Authors:  Ba-Da Lim; Dong-Soon Choi; Insan Jang; Bong-Kuen Cha
Journal:  Korean J Orthod       Date:  2019-09-24       Impact factor: 1.372

8.  Measurement error and reliability of three available 3D superimposition methods in growing patients.

Authors:  Cecilia Ponce-Garcia; Antonio Carlos de Oliveira Ruellas; Lucia Helena Soares Cevidanes; Carlos Flores-Mir; Jason P Carey; Manuel Lagravere-Vich
Journal:  Head Face Med       Date:  2020-01-27       Impact factor: 2.151

9.  Three-dimensional oropharyngeal airway changes after facemask therapy using low-dose computed tomography: a clinical trial with a retrospectively collected control group.

Authors:  Amr H Husson; Ahmad S Burhan; Mohammad Y Hajeer; Fehmieh R Nawaya
Journal:  Prog Orthod       Date:  2021-12-23       Impact factor: 2.750