Literature DB >> 21380779

Clinical review and analysis of complications of totally implantable venous access devices for chemotherapy.

Jung Tae Kim1, Tae Yun Oh, Woon Ha Chang, Young Kyun Jeong.   

Abstract

Since the first implant of totally implantable venous access device (TIVAD), performed by Niederhuber and colleague in 1982, the systems have increasingly been used in the field of oncology. We analyzed the clinical reviews and complications of TIVAD in an effort to achieve optimal management. We retrospectively studied 442 cases with TIVAD device at our hospital and we report the results. Four hundred and forty-two TIVAD were placed in the right subclavian vein in 345 cases, the left subclavian vein in 93 cases, the right jugular vein in 2 cases, the left jugular vein in 1 case, and the right femoral vein in 1 case. The immediate complications were 28 cases in malposition of the catheter, 10 cases of arterial puncture, and 2 cases of pneumothorax. The late complications were 3 cases of pocket infection, 2 cases of catheter related to sepsis, 3 cases of catheter obstruction, 2 cases of SVC thrombosis, and 1 case of catheter fracture (pinch-off syndrome: Hinke grade 3). There were no other early or late complications. The low rate of complications in the study confirms the safety and convenience of using TIVAD in patients undergoing prolonged chemotherapy. Yet because infection, thrombosis and catheter fracture are the most common long-term complications of TIVAD, early diagnosis and management of these problems can prevent severe complications.

Entities:  

Mesh:

Year:  2011        PMID: 21380779     DOI: 10.1007/s12032-011-9887-y

Source DB:  PubMed          Journal:  Med Oncol        ISSN: 1357-0560            Impact factor:   3.064


  13 in total

Review 1.  Totally implantable vascular access devices for cystic fibrosis.

Authors:  A A-Rahman; D Spencer
Journal:  Cochrane Database Syst Rev       Date:  2003

2.  Complications of an implantable venous access device (Port-a-Cath) during intermittent continuous infusion of chemotherapy.

Authors:  R L Poorter; F N Lauw; W A Bemelman; P J Bakker; C W Taat; C H Veenhof
Journal:  Eur J Cancer       Date:  1996-12       Impact factor: 9.162

3.  A silicone rubber atrial catheter for prolonged parenteral alimentation.

Authors:  J W Broviac; J J Cole; B H Scribner
Journal:  Surg Gynecol Obstet       Date:  1973-04

4.  Pinch-off syndrome: a complication of implantable subclavian venous access devices.

Authors:  D H Hinke; D A Zandt-Stastny; L R Goodman; E J Quebbeman; E A Krzywda; D A Andris
Journal:  Radiology       Date:  1990-11       Impact factor: 11.105

5.  Epidemiology of device-associated infections related to a long-term implantable vascular access device.

Authors:  M J Sotir; C Lewis; E W Bisher; S M Ray; J M Soucie; H M Blumberg
Journal:  Infect Control Hosp Epidemiol       Date:  1999-03       Impact factor: 3.254

6.  Complications of venous access ports in 132 patients with disseminated testicular cancer treated with polychemotherapy.

Authors:  N W Lemmers; M E Gels; D T Sleijfer; J T Plukker; W T van der Graaf; Z J de Langen; J H Droste; H S Koops; H J Hoekstra
Journal:  J Clin Oncol       Date:  1996-11       Impact factor: 44.544

7.  Longterm central venous access in gynecologic cancer patients.

Authors:  V A Minassian; A K Sood; P Lowe; J I Sorosky; A S Al-Jurf; R E Buller
Journal:  J Am Coll Surg       Date:  2000-10       Impact factor: 6.113

8.  Groshong catheter-associated subclavian venous thrombosis.

Authors:  J R Gould; H W Carloss; W L Skinner
Journal:  Am J Med       Date:  1993-10       Impact factor: 4.965

9.  Totally implanted venous and arterial access system to replace external catheters in cancer treatment.

Authors:  J E Niederhuber; W Ensminger; J W Gyves; M Liepman; K Doan; E Cozzi
Journal:  Surgery       Date:  1982-10       Impact factor: 3.982

10.  Experience with subcutaneous infusion ports in three hundred patients.

Authors:  T E Brothers; L K Von Moll; J E Niederhuber; J A Roberts; S Walker-Andrews; W D Ensminger
Journal:  Surg Gynecol Obstet       Date:  1988-04
View more
  15 in total

1.  [Solitary pulmonary nodule in a patient with osteosarcoma of the right humerus].

Authors:  R Csernus; G Grigaliunas; H Zabeck; M Sumkauskaite; M Gődény; B Radeleff; H-U Kauczor; C P Heußel
Journal:  Med Klin Intensivmed Notfmed       Date:  2016-06-17       Impact factor: 0.840

2.  Insertion of totally implantable central venous access devices by surgeons.

Authors:  Hyeonjun An; Chun-Geun Ryu; Eun-Joo Jung; Hyun Jong Kang; Jin Hee Paik; Jung-Hyun Yang; Dae-Yong Hwang
Journal:  Ann Coloproctol       Date:  2015-04-30

3.  Late complications associated with totally implantable venous access port implantation via the internal jugular vein.

Authors:  Shigeaki Tsuruta; Yasutomo Goto; Hideo Miyake; Hidemasa Nagai; Yuichiro Yoshioka; Norihiro Yuasa; Junichi Takamizawa
Journal:  Support Care Cancer       Date:  2019-11-14       Impact factor: 3.603

4.  Long-term outcomes of totally implantable venous access devices.

Authors:  Yi-Chia Wang; Pei-Lin Lin; Wei-Han Chou; Chih-Peng Lin; Chi-Hsiang Huang
Journal:  Support Care Cancer       Date:  2017-02-09       Impact factor: 3.603

5.  Morbidity of chemotherapy administration and satisfaction in breast cancer patients: a comparative study of totally implantable venous access device (TIVAD) versus peripheral venous access usage.

Authors:  Kul Ranjan Singh; Gaurav Agarwal; Gitika Nanda; Gyan Chand; Anjali Mishra; Amit Agarwal; Ashok K Verma; Saroj K Mishra; Puneet Goyal
Journal:  World J Surg       Date:  2014-05       Impact factor: 3.352

6.  Complications and management strategies of totally implantable venous access port insertion through percutaneous subclavian vein.

Authors:  Yusuf Velioğlu; Ahmet Yüksel; Emrah Sınmaz
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2019-10-23       Impact factor: 0.332

7.  Deltoid branch of thoracoacromial vein: a safe alternative entry vessel for intravenous port implantation.

Authors:  Ta-Wei Su; Ching-Feng Wu; Jui-Ying Fu; Po-Jen Ko; Sheng-Yueh Yu; Tsung-Chi Kao; Hong-Chang Hsieh; Ching-Yang Wu
Journal:  Medicine (Baltimore)       Date:  2015-05       Impact factor: 1.889

8.  Experience in totally implantable venous port catheter: Analysis of 3,000 patients in 12 years.

Authors:  Fazlı Yanık; Yekta Altemur Karamustafaoğlu; Adem Karataş; Yener Yörük
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2018-07-03       Impact factor: 0.332

9.  Image-guided chemoport insertion by interventional radiologists: A single-center experience on periprocedural complications.

Authors:  Yazmin Yaacob; Dang V Nguyen; Zahiah Mohamed; A Razali A Ralib; Rozman Zakaria; Sobri Muda
Journal:  Indian J Radiol Imaging       Date:  2013-04

10.  The Treatment Results of a Standard Algorithm for Choosing the Best Entry Vessel for Intravenous Port Implantation.

Authors:  Wen-Cheng Wei; Ching-Yang Wu; Ching-Feng Wu; Jui-Ying Fu; Ta-Wei Su; Sheng-Yueh Yu; Tsung-Chi Kao; Po-Jen Ko
Journal:  Medicine (Baltimore)       Date:  2015-08       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.