Literature DB >> 21375345

Homogeneous immunosubtraction integrated with sample preparation enabled by a microfluidic format.

Akwasi A Apori1, Amy E Herr.   

Abstract

Immunosubtraction is a powerful and resource-intensive laboratory medicine assay that reports both protein mobility and binding specificity. To expedite and automate this electrophoretic assay, we report on advances to the electrophoretic immunosubtraction assay by introducing a homogeneous, not heterogeneous, format with integrated sample preparation. To accomplish homogeneous immunosubtraction, a step-decrease in separation matrix pore-size at the head of a polyacrylamide gel electrophoresis (PAGE) separation channel enables "subtraction" of target analyte when capture antibody is present (as the large immune-complex is excluded from PAGE), but no subtraction when capture antibody is absent. Inclusion of sample preparation functionality via small pore size polyacrylamide membranes is also key to automated operation (i.e., sample enrichment, fluorescence sample labeling, and mixing of sample with free capture antibody). Homogeneous sample preparation and assay operation allows on-the-fly, integrated subtraction of one to multiple protein targets and reuse of each device. Optimization of the assay is detailed which allowed for ~95% subtraction of target with 20% non-specific extraction of large species at the optimal antibody-antigen ratio, providing conditions needed for selective target identification. We demonstrate the assay on putative markers of injury and inflammation in cerebrospinal fluid (CSF), an emerging area of diagnostics research, by rapidly reporting protein mobility and binding specificity within the sample matrix. We simultaneously detect S100B and C-reactive protein, suspected biomarkers for traumatic brain injury (TBI), in ~2 min. Lastly, we demonstrate S100B detection (65 nM) in raw human CSF with an estimated lower limit of detection of 3.25 nM, within the clinically relevant concentration range for detecting TBI in CSF. Beyond the novel CSF assay introduced here, a fully automated immunosubtraction assay would impact a spectrum of routine but labor and time-intensive laboratory medicine assays.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21375345      PMCID: PMC3069757          DOI: 10.1021/ac103219x

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  28 in total

1.  Evaluation of tumor marker S-100 in cerebrospinal fluid from subjects with nonischemic brain pathologies.

Authors:  J R Infante; M Torres-Avisbal; A Martinez; J A Vallejo; C Aguilera; P Contreras; A Benitez; J M Latre
Journal:  Tumour Biol       Date:  2000 Jan-Feb

2.  Changes in CSF S100B and cytokine concentrations in early-phase severe traumatic brain injury.

Authors:  Toshiaki Hayakata; Tadahiko Shiozaki; Osamu Tasaki; Hitoshi Ikegawa; Yoshiaki Inoue; Fujinaka Toshiyuki; Hideo Hosotubo; Fuijita Kieko; Testuji Yamashita; Hiroshi Tanaka; Takeshi Shimazu; Hisashi Sugimoto
Journal:  Shock       Date:  2004-08       Impact factor: 3.454

3.  Cerebrospinal fluid transthyretin: aging and late onset Alzheimer's disease.

Authors:  J M Serot; D Christmann; T Dubost; M Couturier
Journal:  J Neurol Neurosurg Psychiatry       Date:  1997-10       Impact factor: 10.154

Review 4.  Microfluidic diagnostic technologies for global public health.

Authors:  Paul Yager; Thayne Edwards; Elain Fu; Kristen Helton; Kjell Nelson; Milton R Tam; Bernhard H Weigl
Journal:  Nature       Date:  2006-07-27       Impact factor: 49.962

Review 5.  Serum free light chain assessment in monoclonal gammopathy and kidney disease.

Authors:  Colin A Hutchison; Kolitha Basnayake; Paul Cockwell
Journal:  Nat Rev Nephrol       Date:  2009-09-29       Impact factor: 28.314

6.  Microfluidic immunoassays as rapid saliva-based clinical diagnostics.

Authors:  Amy E Herr; Anson V Hatch; Daniel J Throckmorton; Huu M Tran; James S Brennan; William V Giannobile; Anup K Singh
Journal:  Proc Natl Acad Sci U S A       Date:  2007-03-20       Impact factor: 11.205

Review 7.  Electrophoretic analysis of Bence Jones proteinuria.

Authors:  T Marshall; K M Williams
Journal:  Electrophoresis       Date:  1999-06       Impact factor: 3.535

8.  On-chip native gel electrophoresis-based immunoassays for tetanus antibody and toxin.

Authors:  Amy E Herr; Daniel J Throckmorton; Andrew A Davenport; Anup K Singh
Journal:  Anal Chem       Date:  2005-01-15       Impact factor: 6.986

9.  Affinity monolith-integrated poly(methyl methacrylate) microchips for on-line protein extraction and capillary electrophoresis.

Authors:  Xiuhua Sun; Weichun Yang; Tao Pan; Adam T Woolley
Journal:  Anal Chem       Date:  2008-05-15       Impact factor: 6.986

10.  Rapid measurement of S-100B serum protein levels by Elecsys S100 immunoassay in patients undergoing carotid artery stenting or endarterectomy.

Authors:  Thomas Mussack; Volker Klauss; Volker Ruppert; Cornelia Gippner-Steppert; Peter Biberthaler; Uwe Schiemann; Ulrich Hoffmann; Marianne Jochum
Journal:  Clin Biochem       Date:  2006-02-07       Impact factor: 3.281

View more
  9 in total

1.  Microfluidic Western blotting.

Authors:  Alex J Hughes; Amy E Herr
Journal:  Proc Natl Acad Sci U S A       Date:  2012-12-05       Impact factor: 11.205

2.  Fabrication of an Open Microfluidic Device for Immunoblotting.

Authors:  Philippe Abdel-Sayed; Kevin A Yamauchi; Rachel E Gerver; Amy E Herr
Journal:  Anal Chem       Date:  2017-09-07       Impact factor: 6.986

Review 3.  Micro total analysis systems for cell biology and biochemical assays.

Authors:  Michelle L Kovarik; Philip C Gach; Douglas M Ornoff; Yuli Wang; Joseph Balowski; Lila Farrag; Nancy L Allbritton
Journal:  Anal Chem       Date:  2011-10-21       Impact factor: 6.986

4.  A lateral electrophoretic flow diagnostic assay.

Authors:  Robert Lin; Arunan Skandarajah; Rachel E Gerver; Hector D Neira; Daniel A Fletcher; Amy E Herr
Journal:  Lab Chip       Date:  2015-03-21       Impact factor: 6.799

5.  Affinity enrichment for mass spectrometry: improving the yield of low abundance biomarkers.

Authors:  Brianna Kim; Robyn Araujo; Marissa Howard; Ruben Magni; Lance A Liotta; Alessandra Luchini
Journal:  Expert Rev Proteomics       Date:  2018-03-22       Impact factor: 3.940

6.  Microfluidic screening of electrophoretic mobility shifts elucidates riboswitch binding function.

Authors:  Kelly Karns; Jacob M Vogan; Qian Qin; Scott F Hickey; Stephen C Wilson; Ming C Hammond; Amy E Herr
Journal:  J Am Chem Soc       Date:  2013-02-11       Impact factor: 15.419

Review 7.  Point-of-care diagnostics for niche applications.

Authors:  Brian M Cummins; Frances S Ligler; Glenn M Walker
Journal:  Biotechnol Adv       Date:  2016-02-01       Impact factor: 14.227

8.  Microfluidic Western blotting of low-molecular-mass proteins.

Authors:  Rachel E Gerver; Amy E Herr
Journal:  Anal Chem       Date:  2014-10-15       Impact factor: 6.986

9.  Determination of equilibrium dissociation constants for recombinant antibodies by high-throughput affinity electrophoresis.

Authors:  Yuchen Pan; Eric K Sackmann; Karolina Wypisniak; Michael Hornsby; Sammy S Datwani; Amy E Herr
Journal:  Sci Rep       Date:  2016-12-23       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.