Literature DB >> 21369946

Operative treatment of distal radial fractures with locking plate system-a prospective study.

Kenny Kwan1, Tak Wing Lau, Frankie Leung.   

Abstract

The aim of this study was to determine the results of operative treatment of distal radial fractures with a 2.4-mm locking plate system in a single tertiary teaching hospital. Seventy-five patients were recruited into the study between May 2004 and November 2006. There were 41 males and 34 females, with a mean age of 51. Seventy-five percent of patients had AO type C fractures. All patients were allowed free active mobilisation of the wrist joint immediately after surgery. They were followed up at two weeks, three months, six months, one year and two years. Assessments of pain, motion, grip strength, and standard radiographs were performed. The Gartland and Werley functional scores, the modified Green and O'Brien score, and the disabilities of the arm, shoulder and hand (DASH) scores were recorded. The radiographic results at the final follow-up showed a mean of 18° of radial inclination, 5° of volar tilt, 1.3-mm radial shortening, and no articular incongruity. Twenty-nine percent of patients showed grade 1 osteoarthritic changes and 6% had grade 2 changes in their final follow-up radiographs. An excellent or good result was obtained in 98% and 96% of patients according to the Gartland and Werley, and modified Green and O'Brien scores, respectively. The mean DASH score was 11.6, indicating a high level of patient satisfaction. Internal fixation of distal radial fractures with a 2.4-mm locking plate system provided a stable fixation with good clinical outcomes and patient satisfaction.

Entities:  

Mesh:

Year:  2010        PMID: 21369946      PMCID: PMC3047652          DOI: 10.1007/s00264-010-0974-z

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  13 in total

1.  Evaluation of healed Colles' fractures.

Authors:  J J GARTLAND; C W WERLEY
Journal:  J Bone Joint Surg Am       Date:  1951-10       Impact factor: 5.284

2.  X-ray film measurements for healed distal radius fractures.

Authors:  H J Kreder; D P Hanel; M McKee; J Jupiter; G McGillivary; M F Swiontkowski
Journal:  J Hand Surg Am       Date:  1996-01       Impact factor: 2.230

3.  The injury severity score: a method for describing patients with multiple injuries and evaluating emergency care.

Authors:  S P Baker; B O'Neill; W Haddon; W B Long
Journal:  J Trauma       Date:  1974-03

4.  Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures.

Authors:  R Arora; M Lutz; D Fritz; R Zimmermann; J Oberladstätter; M Gabl
Journal:  Arch Orthop Trauma Surg       Date:  2005-05-13       Impact factor: 3.067

5.  Difficult wrist fractures. Perilunate fracture-dislocations of the wrist.

Authors:  W P Cooney; R Bussey; J H Dobyns; R L Linscheid
Journal:  Clin Orthop Relat Res       Date:  1987-01       Impact factor: 4.176

6.  Volar plate fixation of AO type C2 and C3 distal radius fractures, a single-center study of 55 patients.

Authors:  Gerald Gruber; Gruber Gerald; Karl Gruber; Gruber Karl; Christian Giessauf; Giessauf Christian; Heimo Clar; Clar Heimo; Max Zacherl; Zacherl Max; Florentine Fuerst; Fuerst Florentine; Gerwin A Bernhardt; Bernhardt G Alexander
Journal:  J Orthop Trauma       Date:  2008-08       Impact factor: 2.512

7.  Classification and management of carpal dislocations.

Authors:  D P Green; E T O'Brien
Journal:  Clin Orthop Relat Res       Date:  1980-06       Impact factor: 4.176

8.  Prospective study of distal radius fractures treated with a volar locking plate system.

Authors:  Denju Osada; Shuzo Kamei; Koichiro Masuzaki; Morimitsu Takai; Masahiro Kameda; Kazuya Tamai
Journal:  J Hand Surg Am       Date:  2008 May-Jun       Impact factor: 2.230

9.  Comparison of external and percutaneous pin fixation with plate fixation for intra-articular distal radial fractures. A randomized study.

Authors:  Frankie Leung; Yuan-Kun Tu; Winston Y C Chew; Shew-Ping Chow
Journal:  J Bone Joint Surg Am       Date:  2008-01       Impact factor: 5.284

10.  Intra-articular fractures of the distal end of the radius in young adults.

Authors:  J L Knirk; J B Jupiter
Journal:  J Bone Joint Surg Am       Date:  1986-06       Impact factor: 5.284

View more
  8 in total

1.  A comparative study of Colles' fractures in patients between fifty and seventy years of age: percutaneous K-wiring versus volar locking plating.

Authors:  Yih-Shiunn Lee; Tien-Yung Wei; Yu-Chieh Cheng; Tzu-Liang Hsu; Chien-Rae Huang
Journal:  Int Orthop       Date:  2011-12-13       Impact factor: 3.075

2.  Radiological Outcomes of Distal Radius Fractures Managed with 2.7mm Volar Locking Plate Fixation-A Retrospective Analysis.

Authors:  Prem Kotian; Srikanth Mudiganty; Rajendra Annappa; Jose Austine
Journal:  J Clin Diagn Res       Date:  2017-01-01

3.  Complications of Volar Plating of Distal Radius Fractures: A Systematic Review.

Authors:  Todd H Alter; Kristin Sandrowski; Gregory Gallant; Moody Kwok; Asif M Ilyas
Journal:  J Wrist Surg       Date:  2018-08-13

4.  Distal radius fracture fixation in the elderly: does better form equal better function?

Authors:  Dennis K H Yee; Christian Fang; Frankie Leung
Journal:  Ann Transl Med       Date:  2019-12

5.  Comparative clinical and radiographic outcomes between early and delayed wrist mobilization after volar fixed-angle plate fixation of distal radius fracture.

Authors:  Panai Laohaprasitiporn; Kitidate Boonchai; Yuwarat Monteerarat; Roongsak Limthongthang; Torpon Vathana
Journal:  Sci Rep       Date:  2022-06-10       Impact factor: 4.996

6.  Complication rates and reduction potential of palmar versus dorsal locking plate osteosynthesis for the treatment of distal radius fractures.

Authors:  F Wichlas; N P Haas; A Disch; D Machó; S Tsitsilonis
Journal:  J Orthop Traumatol       Date:  2014-07-16

7.  Functional Outcome of Intraarticular Fracture of Distal Radius Managed by Volar Locking Plate.

Authors:  Masroor Ahmed; Naveed Ahmed; Sunil Kumar; Mukesh Kumar; Muhammad Bux; Ghulam Hussain
Journal:  Cureus       Date:  2020-10-31

8.  Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life.

Authors:  Serafim Tsitsilonis; David Machó; Sebastian Manegold; Björn Dirk Krapohl; Florian Wichlas
Journal:  GMS Interdiscip Plast Reconstr Surg DGPW       Date:  2016-07-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.