Literature DB >> 18670287

Volar plate fixation of AO type C2 and C3 distal radius fractures, a single-center study of 55 patients.

Gerald Gruber1, Gruber Gerald, Karl Gruber, Gruber Karl, Christian Giessauf, Giessauf Christian, Heimo Clar, Clar Heimo, Max Zacherl, Zacherl Max, Florentine Fuerst, Fuerst Florentine, Gerwin A Bernhardt, Bernhardt G Alexander.   

Abstract

OBJECTIVES: We hypothesized that volar locked plate fixation of AO type C2 or C3 fractures could effectively maintain radiographic reduction as shown by comparison of immediate postoperative alignment and that seen after more than 12 months' follow-up.
DESIGN: Prospective cohort study.
SETTING: Level II trauma center located in a suburban area. PATIENTS: Fifty-five adult patients with intra-articular fractures of the distal radius. INTERVENTION: Open reduction and internal fixation with a locked volar plate and screws. MAIN OUTCOME MEASUREMENTS: Volar tilt, radial inclination, radial length, and articular incongruity were radiologically assessed immediately postoperatively and at the time of final follow-up (mean follow-up: 29 +/- 7 months).
RESULTS: At final radiographic examination, the average loss of volar tilt was 1.9 +/- 3.3 degrees (P < 0.001) and the average loss of radial inclination was 1.4 +/- 2.8 degrees (P < 0.001). Four patients had more than 5 degrees loss of radial inclination (7.8%), and 22 patients (43.1%) had more than 5 degrees loss of volar tilt. Radial shortening was not statistically significant (P > 0.05).
CONCLUSIONS: The treatment of intra-articular fractures of the distal radius with a volar locked plating system is associated with a small but statistically significant loss of volar tilt and radial inclination upon comparison of immediate postoperative alignment with that seen after more than 12 months' follow-up.

Entities:  

Mesh:

Year:  2008        PMID: 18670287     DOI: 10.1097/BOT.0b013e318180db09

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  9 in total

1.  Prospective study of comminuted articular distal radius fractures stabilized by volar plating in the elderly.

Authors:  Daniel Martinez-Mendez; Alejandro Lizaur-Utrilla; Joaquin de Juan-Herrero
Journal:  Int Orthop       Date:  2018-04-07       Impact factor: 3.075

2.  Complications of Volar Plating of Distal Radius Fractures: A Systematic Review.

Authors:  Todd H Alter; Kristin Sandrowski; Gregory Gallant; Moody Kwok; Asif M Ilyas
Journal:  J Wrist Surg       Date:  2018-08-13

3.  Operative treatment of distal radial fractures with locking plate system-a prospective study.

Authors:  Kenny Kwan; Tak Wing Lau; Frankie Leung
Journal:  Int Orthop       Date:  2010-02-21       Impact factor: 3.075

Review 4.  A systematic review of outcomes and complications of treating unstable distal radius fractures in the elderly.

Authors:  Rafael J Diaz-Garcia; Takashi Oda; Melissa J Shauver; Kevin C Chung
Journal:  J Hand Surg Am       Date:  2011-05       Impact factor: 2.230

5.  The Declining Use of Wrist-Spanning External Fixators.

Authors:  Venus Vakhshori; Alexis D Rounds; Nathanael Heckmann; Ali Azad; Jessica M Intravia; Santano Rosario; Milan Stevanovic; Alidad Ghiassi
Journal:  Hand (N Y)       Date:  2018-08-07

6.  The use of a single volar locking plate for AO C3-type distal radius fractures.

Authors:  Brandon E Earp; Brian Foster; Philip E Blazar
Journal:  Hand (N Y)       Date:  2015-04-30

7.  Fracture heuristics: surgical decision for approaches to distal radius fractures. A surgeon's perspective.

Authors:  Florian Wichlas; Serafim Tsitsilonis; Sebastian Kopf; Björn Dirk Krapohl; Sebastian Manegold
Journal:  GMS Interdiscip Plast Reconstr Surg DGPW       Date:  2017-05-22

8.  Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures.

Authors:  J von Recum; S Matschke; J B Jupiter; D Ring; J-S Souer; M Huber; L Audigé
Journal:  Bone Joint Res       Date:  2012-06-01       Impact factor: 5.853

9.  Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes.

Authors:  Kavin Khatri; Vijay Sharma; Kamran Farooque; Vivek Tiwari
Journal:  Arch Trauma Res       Date:  2016-05-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.