Literature DB >> 8775193

X-ray film measurements for healed distal radius fractures.

H J Kreder1, D P Hanel, M McKee, J Jupiter, G McGillivary, M F Swiontkowski.   

Abstract

In order to understand the effect of malunion on functional outcome, it is essential that deformity be measured in a consistent manner. A standardized method of measuring eight anatomic parameters at the distal radius was developed. By this method, six x-ray films of healed distal radius fractures were subsequently measured by 16 raters. Rater agreement was quantified by using the intraclass correlation coefficient. Tolerance limits were developed in order to estimate the expected margin of error for each parameter. Parameters measured with high rater agreement include ulnar variance, palmar tilt, and radial shift; however, even experienced clinicians did not readily agree on the size of step and gap deformity. Using the method of tolerance limits, one would expect that two randomly chosen clinicians measuring step and gap deformity on a random x-ray film will differ by more than 3 mm at least 10% of the time. Similarly, repeat step or gap measurements by the same observer are expected to differ by more than 2 mm at least 10% of the time. In view of our inability to measure deformity more accurately, the concept of a specific relationship between a given degree of deformity and outcome must be questioned. Prospective research is needed in order to improve our understanding of the precise relationship between malunion and functional outcome.

Entities:  

Mesh:

Year:  1996        PMID: 8775193     DOI: 10.1016/S0363-5023(96)80151-1

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  42 in total

1.  Clinical and radiographic factors associated with distal radioulnar joint instability in distal radius fractures.

Authors:  Bong Cheol Kwon; Bo Kyung Seo; Hyoung-June Im; Goo Hyun Baek
Journal:  Clin Orthop Relat Res       Date:  2012-06-06       Impact factor: 4.176

2.  Internal versus external fixation for unstable distal radius fractures: an up-to-date meta-analysis.

Authors:  Zhuang Cui; Jianhong Pan; Bin Yu; Kairui Zhang; Xiaolong Xiong
Journal:  Int Orthop       Date:  2011-06-23       Impact factor: 3.075

3.  Measurement of ulnar variance on uncalibrated digital radiographic images.

Authors:  Johannes de Vries; J Sebastiaan Souer; David Zurakowski; David Ring
Journal:  Hand (N Y)       Date:  2009-12-22

4.  Comparison of 2D radiography and a semi-automatic CT-based 3D method for measuring change in dorsal angulation over time in distal radius fractures.

Authors:  Albert Christersson; Johan Nysjö; Lars Berglund; Filip Malmberg; Ida-Maria Sintorn; Ingela Nyström; Sune Larsson
Journal:  Skeletal Radiol       Date:  2016-02-27       Impact factor: 2.199

5.  Percutaneous pinning for treating distal radial fractures in adults.

Authors:  Alexia Karantana; Helen Hg Handoll; Ammar Sabouni
Journal:  Cochrane Database Syst Rev       Date:  2020-02-07

6.  Comparative Study of Internal Fixation of the Ulna and Distal Ulna Resection in Patients Older Than 70 Years With Distal Radius and Distal Metaphyseal Ulna Fractures.

Authors:  Jorge G Boretto; Ezequiel E Zaidenberg; Gerardo L Gallucci; Alejandro Sarme; Pablo De Carli
Journal:  Hand (N Y)       Date:  2018-02-20

7.  Operative treatment of distal radial fractures with locking plate system-a prospective study.

Authors:  Kenny Kwan; Tak Wing Lau; Frankie Leung
Journal:  Int Orthop       Date:  2010-02-21       Impact factor: 3.075

8.  Volar Plate Fixation in Patients Older Than 70 Years with AO Type C Distal Radial Fractures: Clinical and Radiologic Outcomes.

Authors:  Nicolas S Piuzzi; Ezequiel E Zaidenberg; Matias Pereira Duarte; Jorge G Boretto; Agustin Donndorff; Gerardo Gallucci; Pablo De Carli
Journal:  J Wrist Surg       Date:  2017-01-06

9.  Distribution of primary osteoarthritis in the ulnar aspect of the wrist and the factors that are correlated with ulnar wrist osteoarthritis: a cross-sectional study.

Authors:  Takeshi Katayama; Hiroshi Ono; Daisuke Suzuki; Manabu Akahane; Shohei Omokawa; Yasuhito Tanaka
Journal:  Skeletal Radiol       Date:  2013-06-18       Impact factor: 2.199

10.  Efficacy of different fixation devices in maintaining an initial reduction for surgically managed distal radius fractures.

Authors:  Loren Geller; Mitchell Bernstein; Alberto Carli; Greg Berry; Rudy Reindl; Edward Harvey
Journal:  Can J Surg       Date:  2009-10       Impact factor: 2.089

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.