BACKGROUND: Accurate aortic root measurements and evaluation of spatial relationships with coronary ostia are crucial in preoperative transcatheter aortic valve implantation assessments. Standardization of measurements may increase intraobserver and interobserver reproducibility to promote procedural success rate and reduce the frequency of procedurally related complications. This study evaluated the accuracy and reproducibility of a novel automated multidetector row computed tomography (MDCT) imaging postprocessing software, 3mensio Valves (version 4.1.sp1, Medical Imaging BV, Bilthoven, The Netherlands), in the assessment of patients with severe aortic stenosis candidates for transcatheter aortic valve implantation.
METHODS: Ninety patients with aortic valve disease were evaluated with 64-row and 320-row MDCT. Aortic valve annular size, aortic root dimensions, and height of the coronary ostia relative to the aortic valve annular plane were measured with the 3mensio Valves software. The measurements were compared with those obtained manually by the Vitrea2 software (Vital Images, Minneapolis, MN).
RESULTS: Assessment of aortic valve annulus and aortic root dimensions were feasible in all the patients using the automated 3mensio Valves software. There were excellent agreements with minimal bias between automated and manual MDCT measurements as demonstrated by Bland-Altman analysis and intraclass correlation coefficients ranging from 0.97 to 0.99. The automated 3mensio Valves software had better interobserver reproducibility and required less image postprocessing time than manual assessment.
CONCLUSIONS: Novel automated MDCT postprocessing imaging software (3mensio Valves) permits reliable, reproducible, and automated assessments of the aortic root dimensions and spatial relations with the surrounding structures. This has important clinical implications for preoperative assessments of patients undergoing transcatheter aortic valve implantation.
Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21352985     DOI: 10.1016/j.athoracsur.2010.09.060

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  15 in total

1.  Sizing the aortic annulus.

Authors:  Alfredo G Cerillo; Massimiliano Mariani; Sergio Berti; Mattia Glauber
Journal:  Ann Cardiothorac Surg       Date:  2012-07

2.  Semi-automatic CT-angiography based evaluation of the aortic annulus in patients prior to TAVR: interchangeability with manual measurements.

Authors:  Dominik Zinsser; Alena B Baumann; Katharina Stella Winter; Fabian Bamberg; Philipp Lange; Konstantin Nikolaou; Maximilian Reiser; Christian Kupatt; Thomas Kröncke; Florian Schwarz
Journal:  Int J Cardiovasc Imaging       Date:  2018-06-05       Impact factor: 2.357

3.  Geometry of the left ventricular outflow tract assessed by 3D TEE in patients with aortic stenosis: impact of upper septal hypertrophy on measurements of Doppler-derived left ventricular stroke volume.

Authors:  Dan Koto; Masaki Izumo; Takafumi Machida; Kengo Suzuki; Kihei Yoneyama; Tomomi Suzuki; Ryo Kamijima; Yasuyuki Kobayashi; Tomoo Harada; Yoshihiro J Akashi
Journal:  J Echocardiogr       Date:  2018-05-24

4.  Geometrical characteristics of aortic root and left ventricular dysfunction in aortic stenosis: quantification of 256-slice coronary CT angiography.

Authors:  Michinobu Nagao; Yuzo Yamasaki; Takeshi Kamitani; Satoshi Kawanami; Masatoshi Kondo; Hiromichi Sonoda; Taisuke Fujioka; Hiroshi Honda
Journal:  Heart Vessels       Date:  2016-10-13       Impact factor: 2.037

5.  Artificial intelligence and automation in valvular heart diseases.

Authors:  Qiang Long; Xiaofeng Ye; Qiang Zhao
Journal:  Cardiol J       Date:  2020-06-22       Impact factor: 2.737

6.  Automatic segmentation of the aortic root in CT angiography of candidate patients for transcatheter aortic valve implantation.

Authors:  M A Elattar; E M Wiegerinck; R N Planken; E Vanbavel; H C van Assen; J Baan; H A Marquering
Journal:  Med Biol Eng Comput       Date:  2014-06-06       Impact factor: 2.602

7.  Cardiovascular magnetic resonance for the assessment of patients undergoing transcatheter aortic valve implantation: a pilot study.

Authors:  Alessio La Manna; Alessandra Sanfilippo; Davide Capodanno; Antonella Salemi; Gesualdo Polizzi; Wanda Deste; Glauco Cincotta; Alessandra Cadoni; Anna Marchese; Michele Figuera; Gian P Ussia; Rosetta Pittalà; Carmelo Privitera; Corrado Tamburino
Journal:  J Cardiovasc Magn Reson       Date:  2011-12-27       Impact factor: 5.364

8.  Semiautomatic, Quantitative Measurement of Aortic Valve Area Using CTA: Validation and Comparison with Transthoracic Echocardiography.

Authors:  V Tuncay; N Prakken; P M A van Ooijen; R P J Budde; T Leiner; M Oudkerk
Journal:  Biomed Res Int       Date:  2015-06-29       Impact factor: 3.411

9.  CT-angiography-based evaluation of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI)-predictive value and optimal thresholds for major anatomic parameters.

Authors:  Florian Schwarz; Philipp Lange; Dominik Zinsser; Martin Greif; Peter Boekstegers; Christoph Schmitz; Maximilian F Reiser; Christian Kupatt; Hans C Becker
Journal:  PLoS One       Date:  2014-08-01       Impact factor: 3.240

10.  Automatic aortic root landmark detection in CTA images for preprocedural planning of transcatheter aortic valve implantation.

Authors:  Mustafa Elattar; Esther Wiegerinck; Floortje van Kesteren; Lucile Dubois; Nils Planken; Ed Vanbavel; Jan Baan; Henk Marquering
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-23       Impact factor: 2.357

View more