Literature DB >> 24903606

Automatic segmentation of the aortic root in CT angiography of candidate patients for transcatheter aortic valve implantation.

M A Elattar1, E M Wiegerinck, R N Planken, E Vanbavel, H C van Assen, J Baan, H A Marquering.   

Abstract

Transcatheter aortic valve implantation is a minimal-invasive intervention for implanting prosthetic valves in patients with aortic stenosis. Accurate automated sizing for planning and patient selection is expected to reduce adverse effects such as paravalvular leakage and stroke. Segmentation of the aortic root in CTA is pivotal to enable automated sizing and planning. We present a fully automated segmentation algorithm to extract the aortic root from CTA volumes consisting of a number of steps: first, the volume of interest is automatically detected, and the centerline through the ascending aorta and aortic root centerline are determined. Subsequently, high intensities due to calcifications are masked. Next, the aortic root is represented in cylindrical coordinates. Finally, the aortic root is segmented using 3D normalized cuts. The method was validated against manual delineations by calculating Dice coefficients and average distance error in 20 patients. The method successfully segmented the aortic root in all 20 cases. The mean Dice coefficient was 0.95 ± 0.03, and the mean radial absolute error was 0.74 ± 0.39 mm, where the interobserver Dice coefficient was 0.95 ± 0.03 and the mean error was 0.68 ± 0.34 mm. The proposed algorithm showed accurate results compared to manual segmentations.

Entities:  

Mesh:

Year:  2014        PMID: 24903606     DOI: 10.1007/s11517-014-1165-7

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  15 in total

1.  Complete valvular heart apparatus model from 4D cardiac CT.

Authors:  Sasa Grbic; Razvan Ionasec; Dime Vitanovski; Ingmar Voigt; Yang Wang; Bogdan Georgescu; Nassir Navab; Dorin Comaniciu
Journal:  Med Image Anal       Date:  2012-03-01       Impact factor: 8.545

2.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery.

Authors:  Martin B Leon; Craig R Smith; Michael Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; David L Brown; Peter C Block; Robert A Guyton; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Pamela S Douglas; John L Petersen; Jodi J Akin; William N Anderson; Duolao Wang; Stuart Pocock
Journal:  N Engl J Med       Date:  2010-09-22       Impact factor: 91.245

3.  Patient-specific simulations of transcatheter aortic valve stent implantation.

Authors:  C Capelli; G M Bosi; E Cerri; J Nordmeyer; T Odenwald; P Bonhoeffer; F Migliavacca; A M Taylor; S Schievano
Journal:  Med Biol Eng Comput       Date:  2012-02       Impact factor: 2.602

4.  Aortic dimensions and the risk of dissection.

Authors:  Raimund Erbel; Holger Eggebrecht
Journal:  Heart       Date:  2006-01       Impact factor: 5.994

5.  Patient specific models for planning and guidance of minimally invasive aortic valve implantation.

Authors:  I Waechter; R Kneser; G Korosoglou; J Peters; N H Bakker; R van der Boomen; J Weese
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

6.  Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI).

Authors:  Alec Vahanian; Ottavio Alfieri; Nawwar Al-Attar; Manuel Antunes; Jeroen Bax; Bertrand Cormier; Alain Cribier; Peter De Jaegere; Gerard Fournial; Arie Pieter Kappetein; Jan Kovac; Susanne Ludgate; Francesco Maisano; Neil Moat; Friedrich Mohr; Patrick Nataf; Luc Piérard; José Luis Pomar; Joachim Schofer; Pilar Tornos; Murat Tuzcu; Ben van Hout; Ludwig K Von Segesser; Thomas Walther
Journal:  Eur Heart J       Date:  2008-05-12       Impact factor: 29.983

7.  Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis.

Authors:  Jan Baan; Ze Yie Yong; Karel T Koch; José P S Henriques; Berto J Bouma; Marije M Vis; Riccardo Cocchieri; Jan J Piek; Bas A J M de Mol
Journal:  Am Heart J       Date:  2010-03       Impact factor: 4.749

8.  Automated assessment of the aortic root dimensions with multidetector row computed tomography.

Authors:  Victoria Delgado; Arnold C T Ng; Joanne D Schuijf; Frank van der Kley; Miriam Shanks; Laurens F Tops; Nico R L van de Veire; Albert de Roos; Lucia J M Kroft; Martin J Schalij; Jeroen J Bax
Journal:  Ann Thorac Surg       Date:  2011-03       Impact factor: 4.330

9.  3D segmentation of abdominal aorta from CT-scan and MR images.

Authors:  Anthony Adam Duquette; Pierre-Marc Jodoin; Olivier Bouchot; Alain Lalande
Journal:  Comput Med Imaging Graph       Date:  2012-01-17       Impact factor: 4.790

10.  Transapical transcatheter aortic valve implantation: follow-up to 3 years.

Authors:  Jian Ye; Anson Cheung; Samuel V Lichtenstein; Fabian Nietlispach; Saad Albugami; Jean-Bernard Masson; Christopher R Thompson; Brad Munt; Robert Moss; Ronald G Carere; W R Eric Jamieson; John G Webb
Journal:  J Thorac Cardiovasc Surg       Date:  2010-05       Impact factor: 5.209

View more
  11 in total

1.  Automated Segmentation of Tissues Using CT and MRI: A Systematic Review.

Authors:  Leon Lenchik; Laura Heacock; Ashley A Weaver; Robert D Boutin; Tessa S Cook; Jason Itri; Christopher G Filippi; Rao P Gullapalli; James Lee; Marianna Zagurovskaya; Tara Retson; Kendra Godwin; Joey Nicholson; Ponnada A Narayana
Journal:  Acad Radiol       Date:  2019-08-10       Impact factor: 3.173

2.  Recursive multiresolution convolutional neural networks for 3D aortic valve annulus planimetry.

Authors:  Pascal Theriault-Lauzier; Hind Alsosaimi; Negareh Mousavi; Jean Buithieu; Marco Spaziano; Giuseppe Martucci; James Brophy; Nicolo Piazza
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-03-04       Impact factor: 2.924

3.  A monocentric centerline extraction method for ring-like blood vessels.

Authors:  Fengjun Zhao; Feifei Sun; Yuqing Hou; Yanrong Chen; Dongmei Chen; Xin Cao; Huangjian Yi; Bin Wang; Xiaowei He; Jimin Liang
Journal:  Med Biol Eng Comput       Date:  2017-09-02       Impact factor: 2.602

4.  Artificial intelligence and automation in valvular heart diseases.

Authors:  Qiang Long; Xiaofeng Ye; Qiang Zhao
Journal:  Cardiol J       Date:  2020-06-22       Impact factor: 2.737

5.  Quantification of the Thoracic Aorta and Detection of Aneurysm at CT: Development and Validation of a Fully Automatic Methodology.

Authors:  Fabiola Bezerra de Carvalho Macruz; Charles Lu; Julia Strout; Angelo Takigami; Rupert Brooks; Sean Doyle; Min Yun; Varun Buch; Sandeep Hedgire; Brian Ghoshhajra
Journal:  Radiol Artif Intell       Date:  2022-02-23

Review 6.  Machine learning applications in cardiac computed tomography: a composite systematic review.

Authors:  Jonathan James Hyett Bray; Moghees Ahmad Hanif; Mohammad Alradhawi; Jacob Ibbetson; Surinder Singh Dosanjh; Sabrina Lucy Smith; Mahmood Ahmad; Dominic Pimenta
Journal:  Eur Heart J Open       Date:  2022-03-17

7.  Automated 3D segmentation and diameter measurement of the thoracic aorta on non-contrast enhanced CT.

Authors:  Zahra Sedghi Gamechi; Lidia R Bons; Marco Giordano; Daniel Bos; Ricardo P J Budde; Klaus F Kofoed; Jesper Holst Pedersen; Jolien W Roos-Hesselink; Marleen de Bruijne
Journal:  Eur Radiol       Date:  2019-01-23       Impact factor: 5.315

8.  Automatic aortic root landmark detection in CTA images for preprocedural planning of transcatheter aortic valve implantation.

Authors:  Mustafa Elattar; Esther Wiegerinck; Floortje van Kesteren; Lucile Dubois; Nils Planken; Ed Vanbavel; Jan Baan; Henk Marquering
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-23       Impact factor: 2.357

9.  Dynamics of the aortic annulus in 4D CT angiography for transcatheter aortic valve implantation patients.

Authors:  Mustafa A Elattar; Leon W Vink; Martijn S van Mourik; Jan Baan; Ed T vanBavel; R Nils Planken; Henk A Marquering
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

10.  Automatic Aortic Valve Cusps Segmentation from CT Images Based on the Cascading Multiple Deep Neural Networks.

Authors:  Gakuto Aoyama; Longfei Zhao; Shun Zhao; Xiao Xue; Yunxin Zhong; Haruo Yamauchi; Hiroyuki Tsukihara; Eriko Maeda; Kenji Ino; Naoki Tomii; Shu Takagi; Ichiro Sakuma; Minoru Ono; Takuya Sakaguchi
Journal:  J Imaging       Date:  2022-01-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.