Changes in corneal biomechanics and applanation tonometry with induced corneal swelling.

William Lau1, David Pye.   

Abstract

PURPOSE: To investigate the changes in Goldmann applanation tonometry (GAT) and Ocular Response Analyzer (ORA) measurements with corneal edema induced by contact lenses.
METHODS: Twenty-five healthy, normal subjects (age, 23 ± 2 years) had central corneal radius (CCR), ORA, GAT, and central corneal thickness (CCT) measurements performed in both eyes before a thick, soft hydrogel contact lens was worn with eye closure for 2 hours in one eye. Measurements were repeated immediately after lens removal and every 20 minutes thereafter for the following hour.
RESULTS: The experimental and control eyes behaved asymmetrically over time (repeated measures analysis of variance [RMANOVA]; P < 0.05) for all variables except CCR. GAT, ORA Goldmann-correlated intraocular pressure (ORAg), and ORA corneal-compensated intraocular pressure (ORAcc) showed comparable overestimations, whereas corneal hysteresis (CH) and corneal resistance factor (CRF) responded to corneal swelling in dissimilar ways (RMANOVA; α = 0.05). The variation in GAT in experimental eyes could be predicted by changes in CRF (0.85 [0.23] mm Hg ΔGAT/mm Hg ΔCRF; P < 0.001), but not by CCT or CH. The covariation of both CH and CRF with CCT was influenced by the presence of corneal swelling (Eye×ΔCCT interaction, P < 0.001 and P = 0.003, respectively).
CONCLUSIONS: The GAT overestimation caused by small amounts of corneal swelling represents an overall increase in corneal rigidity, which is partially characterized by CRF. In contrast, CH does not appear to usefully quantify biomechanical changes induced by corneal swelling. The accuracy of ORAcc is affected by corneal swelling.

Entities:  

Mesh:

Year:  2011        PMID: 21345994     DOI: 10.1167/iovs.10-6754

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  11 in total

1.  Correlation between biomechanical responses of posterior sclera and IOP elevations during micro intraocular volume change.

Authors:  Hugh J Morris; Junhua Tang; Benjamin Cruz Perez; Xueliang Pan; Richard T Hart; Paul A Weber; Jun Liu
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-11-01       Impact factor: 4.799

2.  Corneal Biomechanical Changes Following Toric Soft Contact Lens Wear.

Authors:  Somayeh Radaie-Moghadam; Hassan Hashemi; Ebrahim Jafarzadehpur; Abbas Ali Yekta; Mehdi Khabazkhoob
Journal:  J Ophthalmic Vis Res       Date:  2016 Apr-Jun

3.  A retrospective analysis of intraocular pressure changes after cataract surgery with the use of prednisolone acetate 1% versus difluprednate 0.05%.

Authors:  Yael Kusne; Paul Kang; Robert E Fintelmann
Journal:  Clin Ophthalmol       Date:  2016-11-23

4.  Biomechanical Properties of the Cornea Using a Dynamic Scheimpflug Analyzer in Healthy Eyes.

Authors:  Hun Lee; David Sung Yong Kang; Byoung Jin Ha; Jin Young Choi; Eung Kweon Kim; Kyoung Yul Seo; Tae Im Kim
Journal:  Yonsei Med J       Date:  2018-11       Impact factor: 2.759

5.  Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas.

Authors:  George A Kontadakis; Alexandros Pennos; Iro Pentari; George D Kymionis; Ioannis G Pallikaris; Harilaos Ginis
Journal:  Ther Adv Ophthalmol       Date:  2020-06-10

6.  Correlation between corneal thickness, keratometry, age, and differential pressure difference in healthy eyes.

Authors:  Ahmet Colakoglu; Iffet Emel Colakoglu; Cemile Banu Cosar
Journal:  Sci Rep       Date:  2021-02-18       Impact factor: 4.379

7.  Tonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry.

Authors:  Anne Herr; Andreas Remky; Thalia Hirsch; Corinna Rennings; Niklas Plange
Journal:  Clin Ophthalmol       Date:  2013-05-03

8.  Biomechanical parameters of the cornea measured with the Ocular Response Analyzer in normal eyes.

Authors:  Aachal Kotecha; Richard A Russell; Angelos Sinapis; Sayeh Pourjavan; Dimitros Sinapis; David F Garway-Heath
Journal:  BMC Ophthalmol       Date:  2014-01-30       Impact factor: 2.209

Review 9.  Corneal biomechanical properties in different ocular conditions and new measurement techniques.

Authors:  Nery Garcia-Porta; Paulo Fernandes; Antonio Queiros; Jose Salgado-Borges; Manuel Parafita-Mato; Jose Manuel González-Méijome
Journal:  ISRN Ophthalmol       Date:  2014-03-04

10.  C3 Transferase-Expressing scAAV2 Transduces Ocular Anterior Segment Tissues and Lowers Intraocular Pressure in Mouse and Monkey.

Authors:  Junkai Tan; Xizhen Wang; Suping Cai; Fen He; Daren Zhang; Dongkan Li; Xianjun Zhu; Liang Zhou; Ning Fan; Xuyang Liu
Journal:  Mol Ther Methods Clin Dev       Date:  2019-11-29       Impact factor: 6.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.