Reduced exposure using asymmetric cone beam processing for wide area detector cardiac CT.

Arash Bedayat1, Frank J Rybicki, Kanako Kumamaru, Sara L Powers, Jason Signorelli, Michael L Steigner, Chloe Steveson, Shigeyoshi Soga, Kimberly Adams, Dimitrios Mitsouras, Melvin Clouse, Richard T Mather.   

Abstract

The purpose of this study was to estimate dose reduction after implementation of asymmetrical cone beam processing using exposure differences measured in a water phantom and a small cohort of clinical coronary CTA patients. Two separate 320 × 0.5 mm detector row scans of a water phantom used identical cardiac acquisition parameters before and after software modifications from symmetric to asymmetric cone beam acquisition and processing. Exposure was measured at the phantom surface with Optically Stimulated Luminescence (OSL) dosimeters at 12 equally spaced angular locations. Mean HU and standard deviation (SD) for both approaches were compared using ROI measurements obtained at the center plus four peripheral locations in the water phantom. To assess image quality, mean HU and standard deviation (SD) for both approaches were compared using ROI measurements obtained at five points within the water phantom. Retrospective evaluation of 64 patients (37 symmetric; 27 asymmetric acquisition) included clinical data, scanning parameters, quantitative plus qualitative image assessment, and estimated radiation dose. In the water phantom, the asymmetric cone beam processing reduces exposure by approximately 20% with no change in image quality. The clinical coronary CTA patient groups had comparable demographics. The estimated dose reduction after implementation of the asymmetric approach was roughly 24% with no significant difference between the symmetric and asymmetric approach with respect to objective measures of image quality or subjective assessment using a four point scale. When compared to a symmetric approach, the decreased exposure, subsequent lower patient radiation dose, and similar image quality from asymmetric cone beam processing supports its routine clinical use.

Entities:  

Mesh:

Year:  2011        PMID: 21336552      PMCID: PMC3111872          DOI: 10.1007/s10554-011-9814-5

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  8 in total

1.  Characterization and correction of beam-hardening artifacts during dynamic volume CT assessment of myocardial perfusion.

Authors:  Kakuya Kitagawa; Richard T George; Armin Arbab-Zadeh; João A C Lima; Albert C Lardo
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

Review 2.  Strategies for radiation-dose reduction and image-quality optimization in multidetector computed tomographic coronary angiography.

Authors:  Felipe S Torres; Andrew M Crean; Elsie T Nguyen; Narinder Paul
Journal:  Can Assoc Radiol J       Date:  2010-06-04       Impact factor: 2.248

3.  Estimated risks of radiation-induced fatal cancer from pediatric CT.

Authors:  D Brenner; C Elliston; E Hall; W Berdon
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

4.  National survey of doses from CT in the UK: 2003.

Authors:  P C Shrimpton; M C Hillier; M A Lewis; M Dunn
Journal:  Br J Radiol       Date:  2006-12       Impact factor: 3.039

5.  Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography.

Authors:  Michael L Steigner; Hansel J Otero; Tianxi Cai; Dimitrios Mitsouras; Leelakrishna Nallamshetty; Amanda G Whitmore; Hale Ersoy; Noah A Levit; Marcelo F Di Carli; Frank J Rybicki
Journal:  Int J Cardiovasc Imaging       Date:  2008-07-29       Impact factor: 2.357

6.  Initial evaluation of coronary images from 320-detector row computed tomography.

Authors:  Frank J Rybicki; Hansel J Otero; Michael L Steigner; Gabriel Vorobiof; Leelakrishna Nallamshetty; Dimitrios Mitsouras; Hale Ersoy; Richard T Mather; Philip F Judy; Tianxi Cai; Karl Coyner; Kurt Schultz; Amanda G Whitmore; Marcelo F Di Carli
Journal:  Int J Cardiovasc Imaging       Date:  2008-03-27       Impact factor: 2.357

7.  Iodinated contrast opacification gradients in normal coronary arteries imaged with prospectively ECG-gated single heart beat 320-detector row computed tomography.

Authors:  Michael L Steigner; Dimitrios Mitsouras; Amanda G Whitmore; Hansel J Otero; Chunliang Wang; Orla Buckley; Noah A Levit; Alia Z Hussain; Tianxi Cai; Richard T Mather; Orjan Smedby; Marcelo F DiCarli; Frank J Rybicki
Journal:  Circ Cardiovasc Imaging       Date:  2009-12-31       Impact factor: 7.792

Review 8.  Strategies for reducing radiation dose in CT.

Authors:  Cynthia H McCollough; Andrew N Primak; Natalie Braun; James Kofler; Lifeng Yu; Jodie Christner
Journal:  Radiol Clin North Am       Date:  2009-01       Impact factor: 2.303

  8 in total
  12 in total

1.  Examination of the optimal temporal resolution required for computed tomography coronary angiography.

Authors:  Kazuya Ohashi; Katsuhiro Ichikawa; Masaki Hara; Tatsuya Kawai; Hiroshi Kunitomo; Ryo Higashide; Yuta Shibamoto
Journal:  Radiol Phys Technol       Date:  2013-05-26

Review 2.  Cardiovascular imaging 2012 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire; Ernst E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2013-04       Impact factor: 2.357

3.  Coronary CT angiography using the second-generation 320-detector row CT: assessment of image quality and radiation dose in various heart rates compared with the first-generation scanner.

Authors:  Nobuo Tomizawa; Eriko Maeda; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2013-05-17       Impact factor: 2.357

4.  Minimizing the acquisition phase in coronary CT angiography using the second generation 320-row CT.

Authors:  Nobuo Tomizawa; Shigeaki Kanno; Eriko Maeda; Masaaki Akahane; Rumiko Torigoe; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2014-04-28       Impact factor: 2.374

5.  Submillisievert median radiation dose for coronary angiography with a second-generation 320-detector row CT scanner in 107 consecutive patients.

Authors:  Marcus Y Chen; Sujata M Shanbhag; Andrew E Arai
Journal:  Radiology       Date:  2013-01-22       Impact factor: 11.105

6.  Validity of the size-specific dose estimate in adults undergoing coronary CT angiography: comparison with the volume CT dose index.

Authors:  Masafumi Kidoh; Daisuke Utsunomiya; Seitaro Oda; Yoshinori Funama; Hideaki Yuki; Takeshi Nakaura; Noriyuki Kai; Takeshi Nozaki; Yasuyuki Yamashita
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-06       Impact factor: 2.357

7.  Coronary artery calcium score and CT angiography in asymptomatic elderly patients with high pretest probability for coronary artery disease.

Authors:  Amir Imanzadeh; Elizabeth George; Takeshi Kondo; Shinichi Takase; Makoto Amanuma; Frank J Rybicki; Kanako K Kumamaru
Journal:  Jpn J Radiol       Date:  2015-12-15       Impact factor: 2.374

8.  Prognostic Value of Coronary Computed Tomography (CT) Angiography and Coronary Artery Calcium Score Performed Before Revascularization.

Authors:  Shinichiro Fujimoto; Takeshi Kondo; Kanako K Kumamaru; Tomohiro Shinozaki; Kazuhisa Takamura; Yuko Kawaguchi; Rie Matsumori; Makoto Hiki; Katsumi Miyauchi; Hiroyuki Daida; Frank J Rybicki
Journal:  J Am Heart Assoc       Date:  2015-08-21       Impact factor: 5.501

9.  Upper extremity composite tissue allotransplantation imaging.

Authors:  Elizabeth George; Dimitrios Mitsouras; Kanako K Kumamaru; Nehal Shah; Stacy E Smith; Kurt Schultz; Pamela M Deaver; Katherine M Mullen; Michael L Steigner; Edwin C Gravereaux; Shadpour Demehri; Ericka M Bueno; Simon G Talbot; Bohdan Pomahac; Frank J Rybicki
Journal:  Eplasty       Date:  2013-07-16

10.  Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D).

Authors:  Marcus Y Chen; Michael L Steigner; Steve W Leung; Kanako K Kumamaru; Kurt Schultz; Richard T Mather; Andrew E Arai; Frank J Rybicki
Journal:  Int J Cardiovasc Imaging       Date:  2013-02-13       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.