Literature DB >> 23709040

Examination of the optimal temporal resolution required for computed tomography coronary angiography.

Kazuya Ohashi1, Katsuhiro Ichikawa, Masaki Hara, Tatsuya Kawai, Hiroshi Kunitomo, Ryo Higashide, Yuta Shibamoto.   

Abstract

Sub-second multidetector-row computed tomography systems provide great potential for the further improvement of CT coronary angiography (CTCA). However, because the temporal resolution (TR) of such CT systems is insufficient, blurring and artifacts produced by fast cardiac motion remain as unresolved issues. Previous TR investigations of CTCA were based on the retrospective electrocardiogram-gated multisegment reconstruction technique. However, the results obtained may not necessarily be correct because the TR of multisegment reconstruction may not be substantial due to the insufficient periodicity of cardiac motion. The optimal TR required for better CTCA images was evaluated with use of a dual-source CT system, which has various substantial TR modes (83, 125, and 165 ms). CTCA images of 147 patients with heart rates (HRs) ranging from 36 to 117 beats/minute (bpm) were evaluated visually on a 4-point scale. Our results revealed not only that the 165-ms TR is sufficient for low HRs (≤60 bpm), but also that the 83- and 125-ms TRs are unnecessary for such HRs. The image quality with the 125-ms TR mode was acceptable for the left anterior descending artery, left circumflex artery, and right coronary artery at low to intermediate HRs (≤70 bpm). At high HRs (>70 bpm), the 83-ms TR mode resulted in an excellent image quality for all cases except those with very rapid RCA motion. Adequate TRs for a wide range of heart rates (52-106 bpm) are thus clarified.

Entities:  

Mesh:

Year:  2013        PMID: 23709040     DOI: 10.1007/s12194-013-0218-1

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  23 in total

1.  ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart.

Authors:  M Kachelriess; S Ulzheimer; W A Kalender
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

2.  Do segmented reconstruction algorithms for cardiac multi-slice computed tomography improve image quality?

Authors:  Sandra S Halliburton; Arthur E Stillman; Thomas Flohr; Bernd Ohnesorge; Nancy Obuchowski; Michael Lieber; Wadih Karim; Stacie A Kuzmiak; Jane M Kasper; Richard D White
Journal:  Herz       Date:  2003-02       Impact factor: 1.443

3.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

4.  Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients.

Authors:  Ming-Li Sun; Bin Lu; Run-Ze Wu; Laura Johnson; Lei Han; Gang Liu; Fang-Fang Yu; Zhi-Hui Hou; Yang Gao; Hong-Yu Wang; Shiliang Jiang; Yue-Jin Yang; Shu-Bin Qiao
Journal:  Eur Radiol       Date:  2011-04-12       Impact factor: 5.315

5.  Image quality in reduced-dose coronary CT angiography.

Authors:  Nina V Gagarina; Roy Irwan; Galina Gordina; Ekaterina Fominykh; Paul E Sijens
Journal:  Acad Radiol       Date:  2011-06-11       Impact factor: 3.173

6.  Comparison of dual-energy computed tomography of the heart with single photon emission computed tomography for assessment of coronary artery stenosis and of the myocardial blood supply.

Authors:  Balazs Ruzsics; Florian Schwarz; U Joseph Schoepf; Yeong Shyan Lee; Gorka Bastarrika; Salvatore A Chiaramida; Philip Costello; Peter L Zwerner
Journal:  Am J Cardiol       Date:  2009-06-06       Impact factor: 2.778

7.  Non-invasive coronary angiography with 16-slice spiral computed tomography: image quality in patients with high heart rates.

Authors:  H Brodoefel; A Reimann; M Heuschmid; A Küttner; T Beck; C Burgstahler; C D Claussen; S Schroeder; A F Kopp
Journal:  Eur Radiol       Date:  2006-02-24       Impact factor: 5.315

8.  Modulation transfer function-based assessment of temporal resolution: validation for single- and dual-source CT.

Authors:  Dirk Ertel; Evelyn Kröber; Yiannis Kyriakou; Oliver Langner; Willi A Kalender
Journal:  Radiology       Date:  2008-07-15       Impact factor: 11.105

9.  Dual-source versus 64-section CT coronary angiography at lower heart rates: comparison of accuracy and radiation dose.

Authors:  Stephan Baumüller; Sebastian Leschka; Lotus Desbiolles; Paul Stolzmann; Hans Scheffel; Burkhardt Seifert; Borut Marincek; Hatem Alkadhi
Journal:  Radiology       Date:  2009-07-08       Impact factor: 11.105

10.  Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating.

Authors:  Lars Husmann; Ines Valenta; Oliver Gaemperli; Olivier Adda; Valerie Treyer; Christophe A Wyss; Patrick Veit-Haibach; Fuminari Tatsugami; Gustav K von Schulthess; Philipp A Kaufmann
Journal:  Eur Heart J       Date:  2007-12-18       Impact factor: 29.983

View more
  3 in total

1.  Accuracy of gantry rotation time of less than 300 ms for modern MDCT systems.

Authors:  Atsushi Fukuda; Pei-Jan Paul Lin; Kosuke Matsubara; Tosiaki Miyati
Journal:  Radiol Phys Technol       Date:  2014-11-22

2.  Coronary computed tomography angiography using 128-slice dual-source computed tomography in patients with severe calcification.

Authors:  Suguru Sato; Yosuke Horii; Norihiko Yoshimura; Takuya Yagi; Hidefumi Aoyama
Journal:  Jpn J Radiol       Date:  2017-05-26       Impact factor: 2.374

Review 3.  Coronary artery calcium score: a review.

Authors:  Abbas Arjmand Shabestari
Journal:  Iran Red Crescent Med J       Date:  2013-12-05       Impact factor: 0.611

  3 in total