Literature DB >> 21333570

A dual-mode microwave resonator for double electron-electron spin resonance spectroscopy at W-band microwave frequencies.

Igor Tkach1, Giuseppe Sicoli, Claudia Höbartner, Marina Bennati.   

Abstract

We present a dual-mode resonator operating at/near 94 GHz (W-band) microwave frequencies and supporting two microwave modes with the same field polarization at the sample position. Numerical analysis shows that the frequencies of both modes as well as their frequency separation can be tuned in a broad range up to GHz. The resonator was constructed to perform pulsed ELDOR experiments with a variable separation of "pump" and "detection" frequencies up to Δν=350 MHz. To examine its performance, test ESE/PELDOR experiments were performed on a representative biradical system.
Copyright © 2011 Elsevier Inc. All rights reserved.

Mesh:

Year:  2011        PMID: 21333570     DOI: 10.1016/j.jmr.2011.01.012

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  6 in total

1.  Comparison of Overhauser DNP at 0.34 and 3.4 T with Frémy's Salt.

Authors:  M-T Türke; M Bennati
Journal:  Appl Magn Reson       Date:  2012-06-03       Impact factor: 0.831

2.  Concept of Phase Cycling in Pulsed Magnetic Resonance Using Sinusoidal Magnetic Field Modulation.

Authors:  Mark Tseytlin
Journal:  Z Phys Chem (N F)       Date:  2016-11-09       Impact factor: 2.408

3.  Dielectric Resonator for Ka-Band Pulsed EPR Measurements at Cryogenic Temperatures: Probehead Construction and Applications.

Authors:  A Raitsimring; A Astashkin; J H Enemark; A Blank; Y Twig; Y Song; T J Meade
Journal:  Appl Magn Reson       Date:  2012-06-01       Impact factor: 0.831

Review 4.  Technological advances in site-directed spin labeling of proteins.

Authors:  Wayne L Hubbell; Carlos J López; Christian Altenbach; Zhongyu Yang
Journal:  Curr Opin Struct Biol       Date:  2013-07-11       Impact factor: 6.809

5.  Optimization of pulsed DEER measurements for Gd-based labels: choice of operational frequencies, pulse durations and positions, and temperature.

Authors:  A Raitsimring; A V Astashkin; J H Enemark; I Kaminker; D Goldfarb; E D Walter; Y Song; T J Meade
Journal:  Appl Magn Reson       Date:  2013-06       Impact factor: 0.831

Review 6.  Studies of transmembrane peptides by pulse dipolar spectroscopy with semi-rigid TOPP spin labels.

Authors:  Igor Tkach; Ulf Diederichsen; Marina Bennati
Journal:  Eur Biophys J       Date:  2021-02-28       Impact factor: 1.733

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.