Literature DB >> 21327912

Intracoronary optical coherence tomography, basic theory and image acquisition techniques.

F Prati1, M W Jenkins, A Di Giorgio, A M Rollins.   

Abstract

Optical coherence tomography (OCT) imaging is showing great potential as an alternative or complementary tool to intravascular ultrasound (IVUS) for aiding in stent procedures and future diagnosis/treatment of atherosclerosis. Here, we describe the basic theory behind OCT imaging and explain important parameters such as axial resolution, lateral resolution and sensitivity. Also, we describe several image acquisition techniques that have been adopted for OCT imaging.

Entities:  

Mesh:

Year:  2011        PMID: 21327912      PMCID: PMC3720134          DOI: 10.1007/s10554-011-9798-1

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  35 in total

1.  Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound.

Authors:  Ik-Kyung Jang; Brett E Bouma; Dong-Heon Kang; Seung-Jung Park; Seong-Wook Park; Ki-Bae Seung; Kyu-Bo Choi; Milen Shishkov; Kelly Schlendorf; Eugene Pomerantsev; Stuart L Houser; H Thomas Aretz; Guillermo J Tearney
Journal:  J Am Coll Cardiol       Date:  2002-02-20       Impact factor: 24.094

2.  Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source.

Authors:  Michael A Choma; Kevin Hsu; Joseph A Izatt
Journal:  J Biomed Opt       Date:  2005 Jul-Aug       Impact factor: 3.170

3.  Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography.

Authors:  Z Chen; T E Milner; S Srinivas; X Wang; A Malekafzali; M J van Gemert; J S Nelson
Journal:  Opt Lett       Date:  1997-07-15       Impact factor: 3.776

4.  A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods.

Authors:  Patrick W Serruys; John A Ormiston; Yoshinobu Onuma; Evelyn Regar; Nieves Gonzalo; Hector M Garcia-Garcia; Koen Nieman; Nico Bruining; Cécile Dorange; Karine Miquel-Hébert; Susan Veldhof; Mark Webster; Leif Thuesen; Dariusz Dudek
Journal:  Lancet       Date:  2009-03-14       Impact factor: 79.321

5.  Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage.

Authors:  Peter Barlis; Konstantinos Dimopoulos; Jun Tanigawa; Ewa Dzielicka; Giuseppe Ferrante; Francesca Del Furia; Carlo Di Mario
Journal:  Int J Cardiol       Date:  2009-01-19       Impact factor: 4.164

6.  Comparison of optical coherence tomography and intravascular ultrasound for the assessment of in-stent tissue coverage after stent implantation.

Authors:  Davide Capodanno; Francesco Prati; Tomasz Pawlowsky; Maria Cera; Alessio La Manna; Mario Albertucci; Corrado Tamburino
Journal:  EuroIntervention       Date:  2009-11       Impact factor: 6.534

7.  Optical coherence tomography for optical biopsy. Properties and demonstration of vascular pathology.

Authors:  M E Brezinski; G J Tearney; B E Bouma; J A Izatt; M R Hee; E A Swanson; J F Southern; J G Fujimoto
Journal:  Circulation       Date:  1996-03-15       Impact factor: 29.690

8.  ECG-gated versus nongated three-dimensional intracoronary ultrasound analysis: implications for volumetric measurements.

Authors:  N Bruining; C von Birgelen; P J de Feyter; J Ligthart; W Li; P W Serruys; J R Roelandt
Journal:  Cathet Cardiovasc Diagn       Date:  1998-03

9.  ECG-gated three-dimensional intravascular ultrasound: feasibility and reproducibility of the automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans.

Authors:  C von Birgelen; E A de Vrey; G S Mintz; A Nicosia; N Bruining; W Li; C J Slager; J R Roelandt; P W Serruys; P J de Feyter
Journal:  Circulation       Date:  1997-11-04       Impact factor: 29.690

10.  From bench to bedside: a novel technique of acquiring OCT images.

Authors:  Francesco Prati; Maria Cera; Vito Ramazzotti; Fabrizio Imola; Rocco Giudice; Marco Giudice; Silvia De Propris; Mario Albertucci
Journal:  Circ J       Date:  2008-05       Impact factor: 2.993

View more
  13 in total

Review 1.  QCA, IVUS and OCT in interventional cardiology in 2011.

Authors:  Johan H C Reiber; Shengxian Tu; Joan C Tuinenburg; Gerhard Koning; Johannes P Janssen; Jouke Dijkstra
Journal:  Cardiovasc Diagn Ther       Date:  2011-12

2.  Reproducibility of the Carpet View system: a novel technical solution for display and off line analysis of OCT images.

Authors:  Alex Gabriele; Valeria Marco; Laura Gatto; Giulia Paoletti; Luca Di Vito; Fausto Castriota; Enrico Romagnoli; Andrea Ricciardi; Francesco Prati
Journal:  Int J Cardiovasc Imaging       Date:  2014-06-14       Impact factor: 2.357

3.  Volumetric optical frequency domain imaging of pulmonary pathology with precise correlation to histopathology.

Authors:  Lida P Hariri; Matthew B Applegate; Mari Mino-Kenudson; Eugene J Mark; Benjamin D Medoff; Andrew D Luster; Brett E Bouma; Guillermo J Tearney; Melissa J Suter
Journal:  Chest       Date:  2013-01       Impact factor: 9.410

4.  Toward the guidance of transbronchial biopsy: identifying pulmonary nodules with optical coherence tomography.

Authors:  Lida P Hariri; Mari Mino-Kenudson; Matthew B Applegate; Eugene J Mark; Guillermo J Tearney; Michael Lanuti; Colleen L Channick; Alex Chee; Melissa J Suter
Journal:  Chest       Date:  2013-10       Impact factor: 9.410

5.  Using optical coherence tomography to rapidly phenotype and quantify congenital heart defects associated with prenatal alcohol exposure.

Authors:  Ganga Karunamuni; Shi Gu; Yong Qiu Doughman; Amanda I Noonan; Andrew M Rollins; Michael W Jenkins; Michiko Watanabe
Journal:  Dev Dyn       Date:  2015-03-13       Impact factor: 3.780

6.  Semi-Automatic Reconstruction of Patient-Specific Stented Coronaries based on Data Assimilation and Computer Aided Design.

Authors:  Adrien Lefieux; Sara Bridio; David Molony; Marina Piccinelli; Claudio Chiastra; Habib Samady; Francesco Migliavacca; Alessandro Veneziani
Journal:  Cardiovasc Eng Technol       Date:  2022-01-07       Impact factor: 2.305

7.  Long-term follow-up of renal arteries after radio-frequency catheter-based denervation using optical coherence tomography and angiography.

Authors:  Tomasz Roleder; Mariusz Skowerski; Andrzej Wiecek; Marcin Adamczak; Beata Czerwienska; Wojciech Wanha; Tomasz Jadczyk; Lukasz Partyka; Grzegorz Smolka; Wacław Kuczmik; Andrzej Ochała; Dariusz Dudek; Michał Tendera; Zbigniew Gasior; Wojciech Wojakowski
Journal:  Int J Cardiovasc Imaging       Date:  2016-02-16       Impact factor: 2.357

8.  Optical coherence tomography for biofilm detection in chronic rhinosinusitis with nasal polyposis.

Authors:  László Tóth; Attila Vajas; Péter Csomor; András Berta; István Sziklai; Tamás Karosi
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-05-13       Impact factor: 2.503

Review 9.  What Is Hidden Behind Yellow Pixels: from Pathology to Intravascular Imaging of Atherosclerotic Plaque.

Authors:  Karlis Trusinskis; Evija Knoka; Laima Caunite; Mairita Karantajere; Maris Lapsovs; Sandra Paeglite; Ieva Briede; Karlis Grikis; Sanda Jegere; Indulis Kumsars; Inga Narbute; Rudolfs Roze; Dace Sondore; Andrejs Erglis
Journal:  Curr Atheroscler Rep       Date:  2022-02-02       Impact factor: 5.113

Review 10.  Capturing structure and function in an embryonic heart with biophotonic tools.

Authors:  Ganga H Karunamuni; Shi Gu; Matthew R Ford; Lindsy M Peterson; Pei Ma; Yves T Wang; Andrew M Rollins; Michael W Jenkins; Michiko Watanabe
Journal:  Front Physiol       Date:  2014-09-23       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.