Literature DB >> 21316913

Three-dimensional component alignment and functional outcome in computer-navigated total knee arthroplasty: a prospective, randomized study comparing two navigation systems.

Paul Harvie1, Karen Sloan, Richard J Beaver.   

Abstract

Computer navigation in total knee arthroplasty produces better component alignment than conventional techniques. Different navigation systems exist. We undertook a prospective, randomized study comparing 2 navigations systems (Stryker Full Navigation and Stryker Articular Surface Mounted [ASM] navigation systems). Three-dimensional component alignment (Perth computed tomographic knee protocol) and function at 1 year (Knee Society Scores) were assessed. Forty patients participated (20 fully navigated and 20 ASM-navigated total knee arthroplasties). Cohorts were well matched according to sex, age, and body mass index. No statistically significant difference was seen in any parameter of 3-dimensional component alignment or function between cohorts. Operative time for the ASM cohort was significantly less than the fully navigated cohort (P = .001). Both systems performed equally well, and therefore, surgeon preference should determine which system is used.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21316913     DOI: 10.1016/j.arth.2010.12.022

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  16 in total

Review 1.  Computer Assisted Total Knee Arthroplasty: Does it Make a Difference?

Authors:  Emil G Haritinian; Ashvin L Pimpalnerkar
Journal:  Maedica (Buchar)       Date:  2013-06

2.  Clinical, functional, and radiographic outcomes following total knee arthroplasty with patient-specific instrumentation, computer-assisted surgery, and manual instrumentation: a short-term follow-up study.

Authors:  Mark Yaffe; Michael Luo; Nitin Goyal; Philip Chan; Anay Patel; Max Cayo; S David Stulberg
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-12-13       Impact factor: 2.924

3.  Alignment for total knee replacement: a comparison of kinematic axis versus mechanical axis techniques. A cadaver study.

Authors:  Michael Nogler; William Hozack; Dermot Collopy; Eckart Mayr; Gregory Deirmengian; Kathrin Sekyra
Journal:  Int Orthop       Date:  2012-08-14       Impact factor: 3.075

4.  Inconsistencies between navigation data and radiographs in total knee arthroplasty are system-dependent and affect coronal alignment.

Authors:  Alberto Carli; Ahmed Aoude; Avishai Reuven; Bogdan Matache; John Antoniou; David J Zukor
Journal:  Can J Surg       Date:  2014-10       Impact factor: 2.089

5.  Total knee arthroplasty with a computer-navigated saw: a pilot study.

Authors:  Kevin L Garvin; Andres Barrera; Craig R Mahoney; Curtis W Hartman; Hani Haider
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

6.  How to minimize rotational conflict between femoral & tibial component in total knee arthroplasty: the use of femoro-tibial axial synchronizer (Linker).

Authors:  Jai-Gon Seo; Young-Wan Moon; Sang-Min Kim; Sang-Hoon Park
Journal:  Yonsei Med J       Date:  2015-03       Impact factor: 2.759

Review 7.  Does imageless computer-assisted TKA lead to improved rotational alignment or fewer outliers? A systematic review.

Authors:  Marrigje F Meijer; Inge H F Reininga; Alexander L Boerboom; Sjoerd K Bulstra; Martin Stevens
Journal:  Clin Orthop Relat Res       Date:  2014-05-28       Impact factor: 4.176

8.  Mechanical, Anatomical, and Kinematic Axis in TKA: Concepts and Practical Applications.

Authors:  Jeffrey J Cherian; Bhaveen H Kapadia; Samik Banerjee; Julio J Jauregui; Kimona Issa; Michael A Mont
Journal:  Curr Rev Musculoskelet Med       Date:  2014-06

9.  Easy identification of mechanical axis during total knee arthroplasty.

Authors:  Jai-Gon Seo; Young-Wan Moon; Sang-Min Kim; Byung-Chul Jo; Sang-Hoon Park
Journal:  Yonsei Med J       Date:  2013-11       Impact factor: 2.759

Review 10.  Effect of rotational alignment on outcome of total knee arthroplasty.

Authors:  Kars P Valkering; Stefan J Breugem; Michel Pj van den Bekerom; Willem E Tuinebreijer; Rutger C I van Geenen
Journal:  Acta Orthop       Date:  2015-02-24       Impact factor: 3.717

View more