Literature DB >> 21314137

Parallel detection of intrinsic fluorescence from peptides and proteins for quantification during mass spectrometric analysis.

Jason D Russell1, Ryan T Hilger, Daniel T Ladror, Mark A Tervo, Mark Scalf, Michael R Shortreed, Joshua J Coon, Lloyd M Smith.   

Abstract

Direct mass spectrometric quantification of peptides and proteins is compromised by the wide variabilities in ionization efficiency which are hallmarks of both the MALDI and ESI ionization techniques. We describe here the implementation of a fluorescence detection system for measurement of the UV-excited intrinsic fluorescence (UV-IF) from peptides and proteins just prior to their exit and electrospray ionization from an ESI capillary. The fluorescence signal provides a quantifiable measure of the amount of protein or peptide present, while direct or tandem mass spectrometric analysis (MS/MS) on the ESI-generated ions provides information on identity. We fabricated an inexpensive, modular fluorescence excitation and detection device utilizing an ultraviolet light-emitting diode for excitation in a ∼300 nL fluorescence detection cell integrated into the fused-silica separation column. The fluorescence signal is linear over 3 orders of magnitude with on-column limits of detection in the low femtomole range. Chromatographically separated intact proteins analyzed using UV-IF prior to top-down mass spectrometry demonstrated sensitive detection of proteins as large as 77 kDa.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21314137      PMCID: PMC3056920          DOI: 10.1021/ac103023q

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  39 in total

1.  Attomole-level protein fingerprinting based on intrinsic peptide fluorescence.

Authors:  E Okerberg; J B Shear
Journal:  Anal Chem       Date:  2001-04-01       Impact factor: 6.986

2.  Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI?

Authors:  Andrea Schmidt; Michael Karas; Thomas Dülcks
Journal:  J Am Soc Mass Spectrom       Date:  2003-05       Impact factor: 3.109

3.  FLUORESCENCE AND THE STRUCTURE OF PROTEINS. II. FLUORESCENCE OF PEPTIDES CONTAINING TRYPTOPHAN OR TYROSINE.

Authors:  R W COWGILL
Journal:  Biochim Biophys Acta       Date:  1963-09-24

4.  Light-emitting diode-induced fluorescence detection of native proteins in capillary electrophoresis.

Authors:  Chanan Sluszny; Yan He; Edward S Yeung
Journal:  Electrophoresis       Date:  2005-11       Impact factor: 3.535

Review 5.  Mass spectrometry-based quantitative proteomics.

Authors:  Albert J R Heck; Jeroen Krijgsveld
Journal:  Expert Rev Proteomics       Date:  2004-10       Impact factor: 3.940

6.  Improved electrospray ionization efficiency compensates for diminished chromatographic resolution and enables proteomics analysis of tyrosine signaling in embryonic stem cells.

Authors:  Scott B Ficarro; Yi Zhang; Yu Lu; Ahmadali R Moghimi; Manor Askenazi; Elzbieta Hyatt; Eric D Smith; Leah Boyer; Thorsten M Schlaeger; C John Luckey; Jarrod A Marto
Journal:  Anal Chem       Date:  2009-05-01       Impact factor: 6.986

7.  Fluorescence and protein structure. X. Reappraisal of solvent and structural effects.

Authors:  R W Cowgill
Journal:  Biochim Biophys Acta       Date:  1967-01-18

8.  Analytical properties of the nanoelectrospray ion source.

Authors:  M Wilm; M Mann
Journal:  Anal Chem       Date:  1996-01-01       Impact factor: 6.986

9.  Deuterium isotope effects on the fliorescence of tryptophan in peptides and in lysozyme.

Authors:  S S Lehrer
Journal:  J Am Chem Soc       Date:  1970-06-03       Impact factor: 15.419

10.  Analytical characterization of the electrospray ion source in the nanoflow regime.

Authors:  Ioan Marginean; Ryan T Kelly; David C Prior; Brian L LaMarche; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2008-07-29       Impact factor: 6.986

View more
  1 in total

1.  Characterization and quantification of intact 26S proteasome proteins by real-time measurement of intrinsic fluorescence prior to top-down mass spectrometry.

Authors:  Jason D Russell; Mark Scalf; Adam J Book; Daniel T Ladror; Richard D Vierstra; Lloyd M Smith; Joshua J Coon
Journal:  PLoS One       Date:  2013-03-11       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.