| Literature DB >> 21303511 |
Wafaa M K Bakr1, Laila A El Attar, Medhat S Ashour, Ayman M El Toukhy.
Abstract
BACKGROUND: Serodiagnosis of typhoid fever by Widal test based on demonstrating the presence of agglutinins (antibodies) in the serum of an infected patient, against the H (flagellar) and O (somatic) antigens of Salmonella enterica serotype Typhi has been associated with many debates. This is why the aim of this study was to: (i) Compare the diagnostic accuracy of four different commercial kits used to perform Widal test (Remel, BioSystems, Dialab and Biotec). (ii) Compare the sensitivity and specificity of both anti-O and anti-H antibodies. (iii) Compare the validity of single versus paired serum samples with a rising titer for the diagnosis of typhoid fever.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21303511 PMCID: PMC3050682 DOI: 10.1186/1476-0711-10-7
Source DB: PubMed Journal: Ann Clin Microbiol Antimicrob ISSN: 1476-0711 Impact factor: 3.944
Figure 1Positive Widal test for anti-O antibodies.
Figure 2Positive Widal test for anti-H antibodies.
Antibody titers of the 150 clinically diagnosed typhoid fever cases in the first serum samples using 4 different Widal brands
| Widal | Total No. of | No. of samples with given reciprocal titer | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 80 | 160 | 320 | 640 | 1280 | ||||||||
| O | H | O | H | O | H | O | H | O | H | O | H | |
| 131 | 23 | 42 | 45 | 19 | 2 | |||||||
| 129 | 32 | 47 | 35 | 13 | 2 | |||||||
| 125 | 28 | 59 | 30 | 8 | 0 | |||||||
| 103 | 46 | 49 | 8 | 0 | 0 | |||||||
Distribution of the results of 91 serum samples using the 4 Widal brands for anti-O antibodies in relation to their corresponding IgM anti-LPS ELISA results using a cut-off 1/80
| Widal | anti -O | ELISA (91) | Total | |||
|---|---|---|---|---|---|---|
| Positive (67) | Negative (24) | |||||
| Number | % | Number | % | |||
| Negative | 0 | 0.00 | 13 | 54.16 | 13 | |
| Positive | 67 | 100.00 | 11 | 45.83 | 78 | |
| Negative | 0 | 0.00 | 14 | 58.33 | 14 | |
| Positive | 67 | 100.00 | 10 | 41.66 | 77 | |
| Negative | 2 | 2.98 | 14 | 58.33 | 16 | |
| Positive | 65 | 97.01 | 10 | 41.66 | 75 | |
| Negative | 8 | 11.94 | 22 | 91.66 | 30 | |
| Positive | 59 | 88.05 | 2 | 8.33 | 61 | |
Distribution of the results of 91 serum samples using the 4 Widal brands for anti-O antibodies in relation to their corresponding IgM anti-LPS ELISA results using a cut-off 1/160
| Widal brand | anti-O titer ≥ 1/160 | ELISA (91) | Total | |||
|---|---|---|---|---|---|---|
| Positive (67) | Negative (24) | |||||
| Number | % | Number | % | |||
| Negative | 7 | 10.44 | 20 | 83.33 | 27 | |
| Positive | 60 | 89.55 | 4 | 16.66 | 64 | |
| Negative | 11 | 16.41 | 23 | 95.83 | 34 | |
| Positive | 56 | 83.58 | 1 | 4.16 | 57 | |
| Negative | 13 | 19.4 | 20 | 83.33 | 33 | |
| Positive | 54 | 80.59 | 4 | 16.66 | 58 | |
| Negative | 35 | 52.23 | 23 | 95.83 | 58 | |
| Positive | 32 | 47.76 | 1 | 4.16 | 33 | |
Distribution of the results of 91 serum samples using the 4 Widal brands for anti-O antibodies in relation to their corresponding IgM anti-LPS ELISA results using a cut-off 1/320
| Widal brand | anti-O titer | ELISA (91) | Total | |||
|---|---|---|---|---|---|---|
| Positive (67) | Negative (24) | |||||
| Number | % | Number | % | |||
| Negative | 27 | 40.29 | 24 | 100.00 | 51 | |
| Positive | 40 | 59.7 | 0 | 0.00 | 40 | |
| Negative | 36 | 53.73 | 24 | 100.00 | 60 | |
| Positive | 31 | 46.26 | 0 | 0.00 | 31 | |
| Negative | 43 | 64.17 | 24 | 100.00 | 67 | |
| Positive | 24 | 35.82 | 0 | 0.00 | 24 | |
| Negative | 65 | 97.01 | 24 | 100.00 | 89 | |
| Positive | 2 | 2.98 | 0 | 0.00 | 2 | |
Sensitivity, specificity and accuracy of the 4 Widal brand for anti-O antibodies of 91 random serum samples of the 150 clinically diagnosed typhoid fever cases using IgM anti-LPS ELISA as a reference test at three cut-off values
| Using a cut-off 1/80 | |||
|---|---|---|---|
| 100.00% | 54.16% | 87.91% | |
| 100.00% | 58.33% | 89.01% | |
| 97.00% | 58.33% | 86.81% | |
| 88.10% | 91.66% | 89.01% | |
| 89.50% | 83.33% | 87.91% | |
| 83.58% | 95.83% | 86.81% | |
| 80.59% | 83.33% | 81.31% | |
| 47.76% | 95.83% | 60.40% | |
| 59.70% | 100.00% | 70.32% | |
| 46.26% | 100.00% | 60.43% | |
| 35.82% | 100.00% | 52.74% | |
| 2.89% | 100.00% | 28.57% | |
Distribution of the results of 91 serum samples using the 4 Widal brands for anti-H antibodies in relation to their corresponding IgM anti-LPS ELISA results using a cut-off 1/80
| Widal brand | anti-H titer ≥ 1/80 | ELISA (91) | Total | |||
|---|---|---|---|---|---|---|
| Positive (67) | Negative (24) | |||||
| Number | % | Number | % | |||
| Negative | 4 | 5.97 | 2 | 8.33 | 6 | |
| Positive | 63 | 94.02 | 22 | 91.66 | 85 | |
| Negative | 6 | 8.95 | 4 | 16.66 | 10 | |
| Positive | 61 | 91.04 | 20 | 83.33 | 81 | |
| Negative | 9 | 13.43 | 5 | 20.83 | 14 | |
| Positive | 58 | 86.56 | 19 | 79.16 | 77 | |
| Negative | 18 | 26.86 | 11 | 45.83 | 29 | |
| Positive | 49 | 73.13 | 13 | 54.16 | 62 | |
Distribution of the results of 91 serum samples using the 4 Widal brands for anti-H antibodies in relation to their corresponding IgM anti-LPS ELISA results using a cut-off 1/160
| Widal brand | anti-H titer | ELISA (91) | Total | |||
|---|---|---|---|---|---|---|
| Positive (67) | Negative (24) | |||||
| Number | % | Number | % | |||
| Negative | 11 | 16.41 | 5 | 20.83 | 16 | |
| Positive | 56 | 83.58 | 19 | 79.16 | 75 | |
| Negative | 13 | 19.4 | 7 | 29.16 | 20 | |
| Positive | 54 | 80.59 | 17 | 70.83 | 71 | |
| Negative | 18 | 26.86 | 13 | 54.16 | 31 | |
| Positive | 49 | 73.13 | 11 | 45.83 | 60 | |
| Negative | 30 | 44.77 | 22 | 91.66 | 52 | |
| Positive | 37 | 55.22 | 2 | 8.33 | 39 | |
Distribution of the results of 91 serum samples using the 4 Widal brands for anti-H antibodies in relation to their corresponding IgM anti-LPS ELISA results using a cut-off 1/320
| Widal brand | anti-H titer | ELISA (91) | Total | |||
|---|---|---|---|---|---|---|
| Positive (67) | Negative (24) | |||||
| Number | % | Number | % | |||
| Negative | 29 | 43.28 | 19 | 79.16 | 48 | |
| Positive | 38 | 56.71 | 5 | 20.83 | 43 | |
| Negative | 35 | 52.23 | 20 | 74.07 | 60 | |
| Positive | 32 | 47.76 | 4 | 25.92 | 31 | |
| Negative | 43 | 64.17 | 22 | 91.66 | 67 | |
| Positive | 24 | 35.82 | 2 | 8.33 | 24 | |
| Negative | 54 | 80.59 | 24 | 100.00 | 78 | |
| Positive | 13 | 19.4 | 0 | 0.00 | 13 | |
Sensitivity, specificity and accuracy of the 4 Widal brand for anti-H antibodies of 91 random serum samples of the 150 clinically diagnosed typhoid fever cases using IgM anti-LPS ELISA as a reference test at three cut-off values
| Widal Brand | sensitivity | specificity | accuracy |
|---|---|---|---|
| 94.02% | 8.33% | 71.42% | |
| 91.04% | 16.66% | 71.42% | |
| 86.56% | 20.83% | 69.23% | |
| 73.13% | 45.83% | 65.93% | |
| 83.58% | 20.83% | 67.03% | |
| 80.59% | 29.16% | 67.03% | |
| 73.13% | 54.16% | 68.13% | |
| 55.22% | 91.66% | 64.83% | |
| 56.71% | 79.16% | 62.63% | |
| 47.76% | 74.07% | 57.14% | |
| 35.82% | 91.66% | 50.54% | |
| 19.40% | 100.00% | 40.65% | |