Literature DB >> 21285892

Aortic hemodynamics in patients with and without repair of aortic coarctation: in vivo analysis by 4D flow-sensitive magnetic resonance imaging.

Alex Frydrychowicz1, Michael Markl, Daniel Hirtler, Andreas Harloff, Christian Schlensak, Julia Geiger, Brigitte Stiller, Raoul Arnold.   

Abstract

OBJECTIVES: The purpose of this study was to characterize hemodynamic alterations and flow-derived vessel wall parameters in aortic coarctation (CoA) patients with and without operative repair by time-resolved, 3-dimensional, and 3-directional velocity sensitive, phase-contrast magnetic resonance imaging (4D PC MRI) in comparison with healthy subjects. METHODS AND MATERIAL: Twenty-four patients, 12.5 ± 6.4 years after CoA repair, 4 patients without treatment for CoA, and 19 healthy subjects were examined. The study was approved by the institutional review board and signature of written informed consent was obtained from the participants. Echocardiography was performed in patients before participation. MRI studies were conducted by applying flow-sensitive 4D phase-contrast MRI at either 1.5 T (n = 5 patients) or 3 T (all 19 healthy subjects, n = 23 patients). Blood flow visualization was used to evaluate overall aortic helicity, presence of pronounced or additional localized helix flow, and vortex development. Quantitative evaluation comprised the calculation of regional time-averaged absolute wall shear stress (WSS(mag)), peak velocities, and oscillatory shear index at 8 locations distributed along the thoracic aorta and additionally at the site of CoA. Inter- and intraobserver variabilities of calculations were determined.
RESULTS: Volunteers and patients demonstrated the same amount of overall aortic helicity. In contrast, the number of additional localized helix flow or vortex formation was significantly increased in patients (25/28 patients vs. 5/19 normal controls, Fisher exact test: P < 0.001). Vortices in the orifices of the supra-aortic branches were detected in 64.3% (18/28) of patients but in only 11.8% (2/19) of controls (P < 0.001). Quantitative analyses revealed a significant increase in overall aortic WSS(mag) (0.44 ± 0.17 N/m(2) in patients vs. 0.27 ± 0.08 N/m(2) in volunteers, P < 0.005) and a decrease in overall oscillatory shear index. Repeated quantitative analysis showed moderate interobserver and low intraobserver variability. Correlation with echocardiography showed good agreement with MRI which tended to underestimate peak velocities (r = 0.76; Bland-Altman analysis, limits of agreement = -0.57-2.16 m/s, mean = 0.79 m/s).
CONCLUSION: Alterations in aortic hemodynamics after CoA repair are not limited to the specific region of repair, but can be found in the entire aorta. The presented findings highlight the systemic nature of the disease and the need for a systemic diagnostic approach which can be provided by flow-sensitive 4D PC MRI. Furthermore, valuable additional insights on the hemodynamic consequences of coarctation have been shown that may help understanding secondary complications such as restenosis, aneurysm formation, and arterial hypertension.

Entities:  

Mesh:

Year:  2011        PMID: 21285892     DOI: 10.1097/RLI.0b013e3182034fc2

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  35 in total

1.  Magnetic resonance imaging flow quantification of non-occlusive excimer laser-assisted EC-IC high-flow bypass in the treatment of complex intracranial aneurysms.

Authors:  C Brockmann; L Gerigk; P Vajkoczy; C Groden; E Neumaier-Probst
Journal:  Clin Neuroradiol       Date:  2011-12-03       Impact factor: 3.649

2.  Interdependencies of aortic arch secondary flow patterns, geometry, and age analysed by 4-dimensional phase contrast magnetic resonance imaging at 3 Tesla.

Authors:  Alex Frydrychowicz; Alexander Berger; Alejandro Munoz Del Rio; Maximilian F Russe; Jelena Bock; Andreas Harloff; Michael Markl
Journal:  Eur Radiol       Date:  2011-12-30       Impact factor: 5.315

3.  Differences in aortic vortex flow pattern between normal and patients with stroke: qualitative and quantitative assessment using transesophageal contrast echocardiography.

Authors:  Jang-Won Son; Geu-Ru Hong; Woosol Hong; Minji Kim; Helene Houle; Mani A Vannan; Gianni Pedrizzetti; Namsik Chung
Journal:  Int J Cardiovasc Imaging       Date:  2015-11-30       Impact factor: 2.357

4.  Aortic 4D flow MRI in 2 minutes using compressed sensing, respiratory controlled adaptive k-space reordering, and inline reconstruction.

Authors:  Liliana E Ma; Michael Markl; Kelvin Chow; Hyungkyu Huh; Christoph Forman; Alireza Vali; Andreas Greiser; James Carr; Susanne Schnell; Alex J Barker; Ning Jin
Journal:  Magn Reson Med       Date:  2019-02-25       Impact factor: 4.668

5.  Thoracic aorta 3D hemodynamics in pediatric and young adult patients with bicuspid aortic valve.

Authors:  Bradley D Allen; Pim van Ooij; Alex J Barker; Maria Carr; Maya Gabbour; Susanne Schnell; Kelly B Jarvis; James C Carr; Michael Markl; Cynthia Rigsby; Joshua D Robinson
Journal:  J Magn Reson Imaging       Date:  2015-01-22       Impact factor: 4.813

6.  Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation: comparison with young healthy volunteers.

Authors:  Fabian Rengier; Michael Delles; Joachim Eichhorn; Yoo-Jin Azad; Hendrik von Tengg-Kobligk; Julia Ley-Zaporozhan; Rüdiger Dillmann; Hans-Ulrich Kauczor; Roland Unterhinninghofen; Sebastian Ley
Journal:  Int J Cardiovasc Imaging       Date:  2015-02-03       Impact factor: 2.357

Review 7.  4D flow imaging: current status to future clinical applications.

Authors:  Michael Markl; Susanne Schnell; Alex J Barker
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

8.  Measurement of cardiac valve and aortic blood flow velocities in stroke patients: a comparison of 4D flow MRI and echocardiography.

Authors:  Thomas Wehrum; Felix Guenther; Alexander Fuchs; Florian Schuchardt; Anja Hennemuth; Andreas Harloff
Journal:  Int J Cardiovasc Imaging       Date:  2018-01-11       Impact factor: 2.357

9.  Influence of principal component analysis acceleration factor on velocity measurement in 2D and 4D PC-MRI.

Authors:  Gwenaël Pagé; Jérémie Bettoni; Anne-Virginie Salsac; Olivier Balédent
Journal:  MAGMA       Date:  2018-01-22       Impact factor: 2.310

10.  4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography.

Authors:  Maya Gabbour; Susanne Schnell; Kelly Jarvis; Joshua D Robinson; Michael Markl; Cynthia K Rigsby
Journal:  Pediatr Radiol       Date:  2014-12-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.