Literature DB >> 21282755

Late peri-prosthetic femoral fracture as a major mode of failure in uncemented primary hip replacement.

M R Streit1, C Merle, M Clarius, P R Aldinger.   

Abstract

Peri-prosthetic femoral fracture after total hip replacement (THR) is associated with a poor outcome and high mortality. However, little is known about its long-term incidence after uncemented THR. We retrospectively reviewed a consecutive series of 326 patients (354 hips) who had received a CLS Spotorno replacement with an uncemented, straight, collarless tapered titanium stem between January 1985 and December 1989. The mean follow-up was 17 years (15 to 20). The occurrence of peri-prosthetic femoral fracture during follow-up was noted. Kaplan-Meier survival analysis was used to estimate the cumulative incidence of fracture. At the last follow-up, 86 patients (89 hips) had died and eight patients (eight hips) had been lost to follow-up. A total of 14 fractures in 14 patients had occurred. In ten hips, the femoral component had to be revised and in four the fracture was treated by open reduction and internal fixation. The cumulative incidence of peri-prosthetic femoral fracture was 1.6% (95% confidence interval 0.7 to 3.8) at ten years and 4.5% (95% confidence interval 2.6 to 8.0) at 17 years after the primary THR. There was no association between the occurrence of fracture and gender or age at the time of the primary replacement. Our findings indicate that peri-prosthetic femoral fracture is a significant mode of failure in the long term after the insertion of an uncemented CLS Spotorno stem. Revision rates for this fracture rise in the second decade. Further research is required to investigate the risk factors involved in the occurrence of late peri-prosthetic femoral fracture after the implantation of any uncemented stem, and to assess possible methods of prevention.

Entities:  

Mesh:

Year:  2011        PMID: 21282755     DOI: 10.1302/0301-620X.93B2.24329

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  20 in total

1.  Periprosthetic femoral fracture as cause of early revision after short stem hip arthroplasty-a multicentric analysis.

Authors:  Sang-Min Kim; Seung-Beom Han; Kee Hyung Rhyu; Jeong Joon Yoo; Kwang-Jun Oh; Je Hyun Yoo; Kyung-Jae Lee; Seung-Jae Lim
Journal:  Int Orthop       Date:  2018-04-12       Impact factor: 3.075

Review 2.  Incidence and predisposing factors of periprosthetic proximal femoral fractures: a literature review.

Authors:  Claudia C Sidler-Maier; James P Waddell
Journal:  Int Orthop       Date:  2015-03-27       Impact factor: 3.075

3.  Loosely implanted cementless stems may become rotationally stable after loading.

Authors:  Arun Kannan; John R Owen; Jennifer S Wayne; William A Jiranek
Journal:  Clin Orthop Relat Res       Date:  2014-03-25       Impact factor: 4.176

4.  Outcome of periprosthetic femoral fractures following total hip replacement treated with polyaxial locking plate.

Authors:  M F Hoffmann; S Lotzien; T A Schildhauer
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-09-06

5.  Periprosthetic fractures around a cementless hydroxyapatite-coated implant: a new fracture pattern is described.

Authors:  William N Capello; James A D'Antonio; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

6.  High incidence of stem loosening in association with periprosthetic femur fractures in previously well-fixed cementless grit-blasted tapered-wedge stems.

Authors:  Seung-Jae Lim; Kyung-Jae Lee; Byung-Woo Min; Joo-Hyoun Song; Sang-Yeon So; Youn-Soo Park
Journal:  Int Orthop       Date:  2014-11-11       Impact factor: 3.075

7.  Varus stem positioning does not affect long-term functional outcome in cementless anatomical total hip arthroplasty.

Authors:  Remy Coulomb; Alexandre Laborde; Vincent Haignère; François Bauzou; Philippe Marchand; Pascal Kouyoumdjian
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-06       Impact factor: 3.067

8.  Cementless total hip arthroplasty in patients aged ≥80 years.

Authors:  Takahito Yuasa; Katsuhiko Maezawa; Masahiko Nozawa; Kazuo Kaneko
Journal:  J Orthop       Date:  2016-01-22

9.  Long-term (20- to 25-year) results of an uncemented tapered titanium femoral component and factors affecting survivorship.

Authors:  Marcus R Streit; Moritz M Innmann; Christian Merle; Thomas Bruckner; Peter R Aldinger; Tobias Gotterbarm
Journal:  Clin Orthop Relat Res       Date:  2013-05-14       Impact factor: 4.176

Review 10.  Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes.

Authors:  Deborah A Marshall; Karen Pykerman; Jason Werle; Diane Lorenzetti; Tracy Wasylak; Tom Noseworthy; Donald A Dick; Greg O'Connor; Aish Sundaram; Sanne Heintzbergen; Cy Frank
Journal:  Clin Orthop Relat Res       Date:  2014-04-04       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.