Literature DB >> 21278584

Biodegradable implant for tissue repair after glaucoma drainage device surgery.

André Rosentreter1, Andrea M Schild, Sven Dinslage, Thomas S Dietlein.   

Abstract

AIM/
BACKGROUND: To report a novel technique using biodegradable material to cover exposed glaucoma tube shunts.
METHODS: A case report of a single patient who underwent drainage tube shunt surgery with the Baerveldt drainage device for intractable glaucoma. Four months post operation the tube became exposed through necrosis of the overlying scleral flap and conjunctiva. The defect was repaired by fixation of the tube to the sclera, with a slice of an ologen implant as a patch, covered by the adjacent conjunctiva. The patient was followed over a period of 1 year after the surgery.
RESULTS: Successful, lasting closure of the conjunctival defect was achieved without any side effects or complications.
CONCLUSIONS: Erosion of the drainage tube after shunt surgery is a potentially serious problem. It can be successfully managed using a biodegradable implant as a patch before closing the conjunctiva.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 21278584     DOI: 10.1097/IJG.0b013e3182027ab0

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  9 in total

1.  Subconjunctival implantation of ologen Collagen Matrix to treat ocular hypotony after filtration glaucoma surgery.

Authors:  M Tanito; A Okada; Y Mori; I Sano; Y Ikeda; E Fujihara
Journal:  Eye (Lond)       Date:  2017-06-02       Impact factor: 3.775

Review 2.  [Revision surgery in episcleral glaucoma drainage devices].

Authors:  A Rosentreter; T S Dietlein
Journal:  Ophthalmologe       Date:  2016-11       Impact factor: 1.059

3.  Tube Exposure Repair.

Authors:  Stirbu Oana; Jorge Vila
Journal:  J Curr Glaucoma Pract       Date:  2012-10-16

4.  The use of collagen matrix (Ologen) as a patch graft in glaucoma tube shunt surgery, a retrospective chart review.

Authors:  John D Stephens; Steven R Sarkisian
Journal:  F1000Res       Date:  2016-08-01

5.  Deep Sclerectomy with Porous Collagen in Open-angle Glaucoma, Short-term Study.

Authors:  Ahmed Elbably; Tageldin M Othman; Ahmed Mousa; Mohammed Elridy; Wesam Badawy; Mohammed Elbably
Journal:  J Curr Glaucoma Pract       Date:  2018-08-01

6.  New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case.

Authors:  Tamara L Berezina; Robert D Fechtner; Amir Cohen; Eliott E Kim; David S Chu
Journal:  J Curr Glaucoma Pract       Date:  2015-09-25

7.  Patch Grafting Using an Ologen Collagen Matrix to Manage Tubal Exposure in Glaucoma Tube Shunt Surgery.

Authors:  Masaki Tanito; Ichiya Sano; Yoshifumi Ikeda; Etsuko Fujihara
Journal:  Case Rep Ophthalmol       Date:  2018-01-05

8.  Conjunctival repair after glaucoma drainage device exposure using collagen-glycosaminoglycane matrices.

Authors:  André Rosentreter; Alexandra Lappas; Randolf Alexander Widder; Maged Alnawaiseh; Thomas Stefan Dietlein
Journal:  BMC Ophthalmol       Date:  2018-02-27       Impact factor: 2.209

9.  Patch graft using collagen matrix (Ologen) for glaucoma drainage device exposure in a patient with Boston Keratoprosthesis type 1.

Authors:  Samir Jabbour; Mark R Lesk; Mona Harissi-Dagher
Journal:  Am J Ophthalmol Case Rep       Date:  2018-08-18
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.