Literature DB >> 21277140

Can mainstream end-tidal carbon dioxide measurement accurately predict the arterial carbon dioxide level of patients with acute dyspnea in ED.

Orhan Cinar1, Yahya Ayhan Acar, Ibrahim Arziman, Erden Kilic, Yusuf Emrah Eyi, Ramazan Ocal.   

Abstract

OBJECTIVE: This study was designed to determine whether the mainstream end-tidal carbon dioxide (ETCO2) measurement can accurately predict the partial arterial carbon dioxide (Paco2) level of patients presented to emergency department (ED) with acute dyspnea.
METHODS: This prospective, observational study was conducted at a university hospital ED, which serves more than 110 000 patients annually. Nonintubated adult patients presented with acute dyspnea who required arterial blood gas analysis were recruited in the study for a 6-month period between January and July 2010. Patients were asked to breathe through an airway adapter attached to the mainstream capnometer. Arterial blood gas samples were obtained simultaneously.
RESULTS: We included 162 patients during the study period. The mean ETCO2 level was 39.47 ± 10.84 mm Hg (minimum, 19 mm Hg; maximum, 82 mm Hg), and mean Paco2 level was 38.95 ± 12.27 mm Hg (minimum, 16 mm Hg; maximum, 94 mm Hg). There was a positive, strong, statistically significant correlation between ETCO2 and Paco2 (r = 0.911, P < .001). The Bland-Altman plot shows the mean bias ± SD between ETCO2 and Paco2 as 0.5 ± 5 mm Hg (95% confidence interval, -1.3165-0.2680) and the limits of agreement as -10.5 and +9.5 mm Hg. Eighty percent (n = 129) of the ETCO2 measurements were between the range of ±5 mm Hg.
CONCLUSION: Mainstream ETCO2 measurement accurately predicts the arterial Paco2 of patients presented to ED with acute dyspnea. Further studies comparing mainstream and sidestream methods in these patients are required.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21277140     DOI: 10.1016/j.ajem.2010.12.014

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  10 in total

1.  Accurate and stable continuous monitoring module by mainstream capnography.

Authors:  Jiachen Yang; Haitao Wang; Bin Wang; Lei Wang
Journal:  J Clin Monit Comput       Date:  2013-12-06       Impact factor: 2.502

2.  A mainstream monitoring system for respiratory CO2 concentration and gasflow.

Authors:  Jiachen Yang; Bobo Chen; Kyle Burk; Haitao Wang; Jianxiong Zhou
Journal:  J Clin Monit Comput       Date:  2015-07-16       Impact factor: 2.502

Review 3.  Correlation of End-Tidal Carbon Dioxide with Arterial Carbon Dioxide in Mechanically Ventilated Neonates: A Scoping Review.

Authors:  Ingra Pereira Monti Martins; Adriane Muller Nakato; Paula Karina Hembecker; Sérgio Ossamu Ioshii; Percy Nohama
Journal:  Glob Pediatr Health       Date:  2021-05-17

4.  Limitations of End-Tidal CO2 Measured with a Portable Capnometer to Estimate PaCO2 for Patients with Respiratory Disease.

Authors:  Takatoshi Enomoto; Yoshikazu Inoue; Yuichi Adachi; Shunichi Kouno; Yuji Inagaki; Koji Azuma; Kanako Katayama; Naoko Takeuchi; Yoshinobu Matsuda
Journal:  Turk Thorac J       Date:  2021-05

5.  A Low-Power and Portable Biomedical Device for Respiratory Monitoring with a Stable Power Source.

Authors:  Jiachen Yang; Bobo Chen; Jianxiong Zhou; Zhihan Lv
Journal:  Sensors (Basel)       Date:  2015-08-11       Impact factor: 3.576

6.  Dynamic optic nerve sheath diameter responses to short-term hyperventilation measured with sonography in patients under general anesthesia.

Authors:  Ji-Yeon Kim; Hong-Gi Min; Seung-Il Ha; Hye-Won Jeong; Hyungseok Seo; Joung-Uk Kim
Journal:  Korean J Anesthesiol       Date:  2014-10-27

Review 7.  Applications of End-Tidal Carbon Dioxide (ETCO2) Monitoring in Emergency Department; a Narrative Review.

Authors:  Hamed Aminiahidashti; Sajad Shafiee; Alieh Zamani Kiasari; Mohammad Sazgar
Journal:  Emerg (Tehran)       Date:  2018-01-15

8.  Effect of corrective or palliative procedures on arterial to end-tidal carbon dioxide pressure difference in pediatric cardiac surgery.

Authors:  Eissa Bilehjani; Solmaz Fakhari; Alireza Yaghoubi; Yashar Eslampoor; Simin Atashkhoei; Mousa Mirinajad
Journal:  Afr J Paediatr Surg       Date:  2018 Apr-Jun

9.  The correlation between end-tidal carbon dioxide and arterial blood gas parameters in patients evaluated for metabolic acid-base disorders.

Authors:  Elham Pishbin; Ghazaleh Doostkhah Ahmadi; Mohammad Davood Sharifi; Morteza Talebi Deloei; Alireza Sepehri Shamloo; Hamidreza Reihani
Journal:  Electron Physician       Date:  2015-07-20

Review 10.  Capnography as a tool to detect metabolic changes in patients cared for in the emergency setting.

Authors:  Francisco José Cereceda-Sánchez; Jesús Molina-Mula
Journal:  Rev Lat Am Enfermagem       Date:  2017-05-15
  10 in total