| Literature DB >> 28513767 |
Francisco José Cereceda-Sánchez1, Jesús Molina-Mula2.
Abstract
OBJECTIVE: : to evaluate the usefulness of capnography for the detection of metabolic changes in spontaneous breathing patients, in the emergency and intensive care settings.Entities:
Mesh:
Year: 2017 PMID: 28513767 PMCID: PMC5465975 DOI: 10.1590/1518-8345.1756.2885
Source DB: PubMed Journal: Rev Lat Am Enfermagem ISSN: 0104-1169
Figure 1Mainstream adapter for orotracheal tube, on the bottom and on the top, for nasal cannulae with oral portion, aiming the collection of air exhaled through the mouth. As can be seen, the sensor is close to the airway
Figure 2From left to right: simple nasal cannulas, nasal cannulas with oral portion and adapter for OTT in Sidestream systems
Distribution of articles according to the databases. Palma de Mallorca, IB, Spain, 2016
| Database queried | Total of articles found | Articles excluded | Review articles selected |
| EBSCOhost | 19 | 10 | 9 |
| Pubmed | 10 | 4 | 6 |
| IBECS | 1 | 0 | 1 |
| IME Biomedicine | 1 | 0 | 1 |
| LILACS | 0 | ||
| VHL | 3 | 1 | 2 |
| Total phase 1 | 22* | 12* | 10* |
| Total phase 2 (Guided search) | 0 | 0 | 9 |
| Total | 0 | 0 | 19 |
*Removed repeated articles
Types of studies included in this review and total articles found for each scoring, according to the Likert scale. Palma de Mallorca, IB, Spain, 2016
| Type of study | Total articles | 1 Point Likert | 2 Points Likert | 3 Points Likert | 4 Points Likert |
| Review articles | 2 | ||||
| Retrospective Observational Studies | 2 | ||||
| Prospective Observational Studies | 15 | ||||
| Total according to the Likert Scale | 0 | 1 | 3 | 15 |
Different variables analyzed in the included articles. Palma de Mallorca, IB, Spain, 2016
| Author | n | Cannula used | Type of sensor | Capnograph used | Measurement duration |
| Pishbin et al. | 64 | Nc* | Sidestream | Capnocheck | NK/NA |
| Agus et al. | 72 | Nc* | Microstream | MDE Escort Prism | NK/NA |
| Gilhotra & Porter | 58 | Nc* | Sidestream | Philips M3046A. | 1 min |
| Solana et al. | 25 | Nco | Microstream | Philips smarth capnoline O2 pediatrics. | 30 sec-1min |
| Nagler et al. | 130 | Nco | Microstream | Microcap; Oridion. | 1-2 min |
| Kartal et al. | 240 | O | Sidestream | Medlab Cap 10 sidestream. | NK/NA |
| McGillicuddy et al. | 97 | NK/NA | Microstream | Nelcor NBP-70. | NK/NA |
| Soleimanpour et al. | 181 | NK/NA | NK/NA | RESPIRONICS device (model number: 7100). | 1 min |
| Yosefy et al. | 73 | Nc* | Sidestream | OHMEDA Model 4700 Oxycap monitor. | NK/NA |
| Kasuya et al. | 60 | Nco | Mainstream and Microstream | Sidestream (Microcap, Oridion Capnography) Mainstream (cap-ONE; Nihon Kohden) | 5 min |
| García et al. | 121 | Nco | Sidestream | Pryon SC-300. | cont monit |
| Cinar et al. | 162 | adap OTT | Mainstream | EMMA Emergency Capnometer | NK/NA |
| Pekdemir et al. | 114 | Nco | Mainstream and Microstream | Nihon Kohden TG-921T3 in Mainstream. Mindray Benewiew T5 monitor, for sidestream | NK/NA |
| Hunter et al. | 1088 | NK/NA | Microstream | LIFEPAK 12 multiparameter defibrillator/monitors. | 3-5 ventilations |
| Hunter et al. | 201 | Nc* in sidestream, adap OTT Mainstream | Mainstream and Microstream | Capnostream 20 device (Oridion Medical 1987 Ltd). | 3-5 ventilations |
| Delerme et al. | 43 | Nco | Microstream | Datascope, LaCiotat. | NK/NA |
| Jabre et al. | 49 | Nco | Microstream | Microcap, Oridion Capnography Inc. | NK/NA |
* Nc= Nasal cannula; † NK/NA= Did not know/Did not answer; ‡ Nco= Nasal cannula with oral portion; § O= Oral Cannula