Hideya Yamazaki1, Hiroya Shiomi, Takuji Tsubokura, Naohiro Kodani, Takuya Nishimura, Norihiro Aibe, Hiroki Udono, Manabu Nishikata, Yoshimi Baba, Mikio Ogita, Koichi Yamashita, Tadayuki Kotsuma.
Abstract
BACKGROUND: To assess inter-observer variability in delineating target volume and organs at risk in benign tumor adjacent to optic tract as a quality assurance exercise.Entities:
Mesh:
Year: 2011 PMID: 21272369 PMCID: PMC3040152 DOI: 10.1186/1748-717X-6-10
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Reference for planning of pituitary adenoma and meningioma
| Pituitary adenoma | Meningioma | |
|---|---|---|
| PTV = CTV + 1 mm (CTV = GTV), | PTV = CTV + 1 mm (CTV = GTV) | |
| PTV = CTV + 2 - 4 mm (CTV = GTV) | PTV = CTV + 2 - 3 mm (CTV = GTV) | |
| SRS | 15 - 20 Gy marginal dose, 25 Gy or more for secreting pituitary adenoma | 11 - 18 Gy marginal dose (recommended for 14 Gy or more) |
| Conventional fractionated SRT | isocenter 45 - 68 Gy/daily 1.8 Gy/fr., D95 50 - 56 Gy/daily 2 Gy/fr. | |
| SRT | 45 - 50 Gy/25 - 28 fr. | 2 Gy/fr. |
| SRS | Optic tract < 8 - 10 Gy, | |
| Conventional fractionated | ||
| SRT | Optic tract 50 Gy/25 fr | |
| Spinal cord < 50 Gy (10 cm or less in length) | ||
| Retina < 45 Gy | ||
| Lens < 10 Gy | ||
| Brain stem < 60 Gy (1/3 volume) | ||
SRS; stereotactic radiosurgery, SRT; stereotactic radiotherapy,
GTV; gross tumor volume, CTV; clinical treatment volume, PTV; planning target volume, fr.; fraction,
D95; irradiation dose that included 95% volume of PTV
Plan characteristics
| Meningioma | EQD22 (Gy) | Pituitary adenoma | EQD210 (Gy) | |||
|---|---|---|---|---|---|---|
| No of plan | 11 | 10 | ||||
| Tumor | ||||||
| Volume of PTV | 8.06 ± 2.45 | 9.53 ± 1.75 | ||||
| Prescribed dose | 5 | 30 Gy/5 fr. | 40 | 4 | 25 Gy/5 fr. | 31.3 |
| 1 | 16 Gy/1 fr. | 34.6 | 2 | 21 Gy/3 fr. | 29.8 | |
| 1 | 21 Gy/3 fr. | 29.8 | 1 | 22.5 Gy/3 fr. | 32.8 | |
| 1 | 24 Gy/5 fr. | 29.6 | 2 | 24 Gy/5 fr. | 29.6 | |
| 1 | 23 Gy/3 fr. | 33.9 | 1 | 24 Gy/3 fr. | 36 | |
| 1 | 24 Gy/3 fr. | 36 | ||||
| s | ||||||
| Minimal dose/prescribed dose | 83.7 ± 9 range 72 - 90 | 80 ± 12 range 60 - 99 | ||||
| Maximal dose/prescribed dose | 122 ± 15 range 110 - 157 | 129 ± 17 range 105 - 157 | ||||
| OARs | ||||||
| (Gy) | ||||||
| Left eye | 0.12 - 2.25 | 0.02 - 4.48 | ||||
| Right eye | 3.07 - 18.6 | 0.05 - 4.52 | ||||
| Brain stem | 4.97 - 15.4 | 4.5 - 19.5 | 17.3 - 24.74 | 30.0 - 42.9 | ||
| Optic chiasm | 4.61 - 15.4 | 4.1 -- 19.9 | 16.6 - 26.4 | 22 -- 48 | ||
| Left lens | 0.01 - 2.00 | 0.03 - 4.08 | ||||
| Right lens | 0.88 - 6.68 | 0.13 - 3.81 | ||||
| Left optic nerve | 0.79 - 8.96 | 0.4 - 8.5 | 12.4 - 23.4 | 23 - 50 | ||
| Right optic nerve | 7.93 -- 26.4 | 14.6 - 47.9 | 0.37 - 23.4 | 17.5 -- 57.5 | ||
EQD2 = n × d × (α/β+d)/(α/β+2), EQD210; α/β = 10 for PTV and EQD22; α/β = 2 for organs at risk
OARs; organs at risk, fr.; fraction
Figure 1Contours superimposed on the default CT image (Pituitary adenoma). (a) (b) axial section (c) sagittal section (d) coronal section.
Figure 2Contours superimposed on the default CT image (Meningioma). (a) (b) (c) axial section (d) sagittal section (e) coronal section The red lines depict planning target volumes, and the green lines depict delineations of organs at risk from each clinician.
Figure 3Variation in planning treatment volume (PTV) in pituitary adenoma and meningioma cases.
Figure 4Influence of different contours on the DVH analysis. Each contour was layered over the original default plan (Soseikai General Hospital). The dose calculation was made by ShioRIS, and the DVH was calculated using ShioRIS-2. a) Pituitary adenoma:10 contours Left panel. PTV. Default D90 = 25 Gy/5 fractions. According to the applied contours, the D90 median dose was 24.68 Gy (23.34 - 24.78 Gy). Right panel. OAR (left optic nerve). Left optic nerve received 8.79 Gy in default plan (made by T. T.), median 12.41 Gy (8.78 - 23.64 Gy; 23.64 Gy = 268% of default plan) b) Meningioma: 11 contours Left panel. PTV. Default D90 = 30 Gy/5 fractions. According to the applied contours, the D90 median dose was 30.29 Gy (24.24 - 30.66 Gy). Right panel. OAR (right optic nerve). The right optic nerve received a median dose of 19.39 Gy (16.21 - 24.84 Gy; 18.9 Gy in the default plan). Therefore, some plans used 24.24 Gy as a D90 prescribed dose (19% lower dose than anticipated in widen PTV group) when using their contoured PTV. In addition, a higher maximum dose of 24.84 Gy (131% higher dose than default plan 18.9 Gy) was delivered to the right optic nerve in contours used in some institutes.