Korotkoff sound versus oscillometric cuff sphygmomanometers: comparison between auscultatory and DynaPulse blood pressure measurements.

Shiu-Shin Chio1, Elaine M Urbina, Jeffery Lapointe, Jeffrey Tsai, Gerald S Berenson.   

Abstract

Listening to Korotkoff sounds (K-sounds) to determine systolic and diastolic blood pressure (BP) has been the standard for noninvasive BP measurement in medical practices for nearly 100 years. It is the essential tool used for evaluation and assessment of patients with hypertension and risks of cardiovascular diseases (CVD) by physicians and nurses despite limited understanding of the nature of K-sounds. Analyzing cuff oscillometric signals to obtain BP has been the foundation of most digital BP monitors available today. DynaPulse is an oscillometric digital BP monitor that records and analyzes subtle changes of pulse waveforms during the course of a BP measurement while cuff pressure slowly decreases from above systolic to below diastolic. This study compares systolic and diastolic readings obtained by K-sound method following the Bogalusa Heart Study protocol and BP measured by DynaPulse (DP2000A) monitor, in order to better understand the nature and difference between K-sound and oscillometric methods. Analysis of means and differences is applied to BP data collected from 803 subjects examined in the Bogalusa Heart Study. The results indicated: 1) DynaPulse systolic was 9 mm Hg higher (P < .0001) than Phase 1 (K1) systolic, 2) DynaPulse diastolic was 5 mm Hg lower (P < .0001) than Phase 4 (K4), and 3) is less than 1 mm Hg higher than Phase 5 (K5) diastolic (P < .0001), when compared with K-sound auscultatory measurement. Understanding the methods and differences of DynaPulse oscillometric and K-sound BP measurements is important for clinic BP screening and self-BP monitoring, as well as future research to improve hypertension and CVD managements.
Copyright © 2011 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21269907     DOI: 10.1016/j.jash.2010.10.005

Source DB:  PubMed          Journal:  J Am Soc Hypertens        ISSN: 1878-7436


  8 in total

1.  Variant Near FGF5 Has Stronger Effects on Blood Pressure in Chinese With a Higher Body Mass Index.

Authors:  Jin Li; Jinxiu Shi; Wei Huang; Jielin Sun; Ying Wu; Qing Duan; Jingchun Luo; Leslie A Lange; Penny Gordon-Larsen; S Lilly Zheng; Wentao Yuan; Ying Wang; Barry M Popkin; Zengnan Mo; Jianfeng Xu; Shufa Du; Karen L Mohlke; Ethan M Lange
Journal:  Am J Hypertens       Date:  2015-01-23       Impact factor: 2.689

2.  MEthods of ASsessing blood pressUre: identifying thReshold and target valuEs (MeasureBP): a review & study protocol.

Authors:  Kimberly C Blom; Sasha Farina; Yessica-Haydee Gomez; Norm R C Campbell; Brenda R Hemmelgarn; Lyne Cloutier; Donald W McKay; Martin Dawes; Sheldon W Tobe; Peter Bolli; Mark Gelfer; Donna McLean; Gillian Bartlett; Lawrence Joseph; Robin Featherstone; Ernesto L Schiffrin; Stella S Daskalopoulou
Journal:  Curr Hypertens Rep       Date:  2015-04       Impact factor: 5.369

3.  Autonomic and hemodynamic origins of pre-hypertension: central role of heredity.

Authors:  Jason T Davis; Fangwen Rao; Dalal Naqshbandi; Maple M Fung; Kuixing Zhang; Andrew J Schork; Caroline M Nievergelt; Michael G Ziegler; Daniel T O'Connor
Journal:  J Am Coll Cardiol       Date:  2012-06-12       Impact factor: 24.094

4.  Comparison of mercury sphygmomanometry blood pressure readings with oscillometric and central blood pressure in predicting target organ damage in youth.

Authors:  Elaine M Urbina; Philip R Khoury; Connie E McCoy; Stephen R Daniels; Lawrence M Dolan; Thomas R Kimball
Journal:  Blood Press Monit       Date:  2015-06       Impact factor: 1.444

5.  Systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement.

Authors:  Amir M Benmira; Antonia Perez-Martin; Sarah Coudray; Iris Schuster; Isabelle Aichoun; Jérémy Laurent; Fethi Bereski-Reguig; Michel Dauzat
Journal:  J Hypertens       Date:  2017-05       Impact factor: 4.844

6.  Comparison of Systolic Blood Pressure Measurements by Auscultation and Visual Manometer Needle Jump.

Authors:  Samuel A Trigg; Dalan Abreu; Brenan Bitton-Foronda; Francesca C Foley; Ann L Gibson
Journal:  Int J Exerc Sci       Date:  2019-01-01

7.  Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment.

Authors:  Mugeb Al-Harosh; Marat Yangirov; Dmitry Kolesnikov; Sergey Shchukin
Journal:  Sensors (Basel)       Date:  2021-12-17       Impact factor: 3.576

8.  Auscultatory measured normative blood pressure of korean adolescents: using the korean national health and nutrition examination survey 2001-2007.

Authors:  Hae Soon Kim; Mi Jung Park; Min Kyung Oh; Young Mi Hong
Journal:  Korean Circ J       Date:  2012-12-31       Impact factor: 3.243

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.