Literature DB >> 21220552

Retinal nerve fiber layer assessment: area versus thickness measurements from elliptical scans centered on the optic nerve.

Nimesh B Patel1, Xunda Luo, Joe L Wheat, Ronald S Harwerth.   

Abstract

PURPOSE: An evaluation of the retinal nerve fiber layer (RNFL) provides important information on the health of the optic nerve. Standard measurements of the RNFL consider only thickness, but an accurate assessment should also consider axial length, size of the optic nerve head (ONH), blood vessel contribution, and distance of the scan from the ONH margin. In addition, although most primate ONHs are elliptical, the circular scan centered on the ONH is the mainstay in both clinical and research analyses. The purpose of this study was to evaluate thickness and area measures of RNFL cross sections when axial length and ONH shape are included.
METHODS: Circular, raster, and radial scans of left eye optic nerves were acquired from 40 normal rhesus monkeys (Macaca mulatta) using spectral domain optical coherence tomography. The disc margin was identified by manually selecting the RPE/Bruch's membrane opening and ONH border tissue. With a pixel-to-micrometer conversion computed from a three-surface schematic eye, RNFL scans were interpolated at 300 to 600 μm (50-μm increments) from the edge of the ONH. The thickness and area of the RNFL at each distance were obtained by custom programs. Blood vessels in the RNFL were selected and removed from the overall RNFL measures.
RESULTS: The average RNFL thickness decreased systematically from 149 ± 12.0 μm for scans 300 μm from the disc margin to 113 ± 7.2 μm at an eccentricity of 600 μm (P < 0.05). In contrast, the cross-sectional areas of the RNFL did not vary with scan location from the disc margin (0.85 ± 0.07 mm(2) at 300 μm compared with 0.86 ± 0.06 mm(2) at 600 μm). Blood vessels accounted for 9.3% of total RNFL thickness or area, but varied with retinal location. On average, 17.6% of the superior and 14.2% of the inferior RNFL was vascular, whereas blood vessels accounted for only 2.3% of areas of the temporal and nasal RNFL regions.
CONCLUSIONS: In nonhuman primates, with appropriate transverse scaling and ONH shape analysis, the cross-sectional area of the RNFL is independent of scan distance, up to 600 μm from the rim margin, indicating that the axonal composition changes little over this range. The results suggest that, with incorporation of transverse scaling, the RNFL cross-sectional area, rather than RNFL thickness, provides an accurate assessment of the retinal ganglion cell axonal content within the eye.

Entities:  

Mesh:

Year:  2011        PMID: 21220552      PMCID: PMC3088544          DOI: 10.1167/iovs.10-6105

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  83 in total

1.  Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography.

Authors:  E Z Blumenthal; J M Williams; R N Weinreb; C A Girkin; C C Berry; L M Zangwill
Journal:  Ophthalmology       Date:  2000-12       Impact factor: 12.079

2.  The number and diameter distribution of axons in the monkey optic nerve.

Authors:  R M Sanchez; G R Dunkelberger; H A Quigley
Journal:  Invest Ophthalmol Vis Sci       Date:  1986-09       Impact factor: 4.799

3.  A four-surface schematic eye of macaque monkey obtained by an optical method.

Authors:  P Lapuerta; S J Schein
Journal:  Vision Res       Date:  1995-08       Impact factor: 1.886

4.  Laser energy levels for trabecular meshwork damage in the primate eye.

Authors:  H A Quigley; R M Hohman
Journal:  Invest Ophthalmol Vis Sci       Date:  1983-09       Impact factor: 4.799

5.  Enhanced optical coherence tomography imaging by multiple scan averaging.

Authors:  B Sander; M Larsen; L Thrane; J L Hougaard; T M Jørgensen
Journal:  Br J Ophthalmol       Date:  2005-02       Impact factor: 4.638

6.  Blood vessel contributions to retinal nerve fiber layer thickness profiles measured with optical coherence tomography.

Authors:  Donald C Hood; Brad Fortune; Stella N Arthur; Danli Xing; Jennifer A Salant; Robert Ritch; Jeffrey M Liebmann
Journal:  J Glaucoma       Date:  2008 Oct-Nov       Impact factor: 2.503

7.  Retinal nerve fiber layer thickness in normals measured by spectral domain OCT.

Authors:  Delia Bendschneider; Ralf P Tornow; Folkert K Horn; Robert Laemmer; Christopher W Roessler; Anselm G Juenemann; Friedrich E Kruse; Christian Y Mardin
Journal:  J Glaucoma       Date:  2010-09       Impact factor: 2.503

8.  The nerve fiber layer in the diagnosis of glaucoma.

Authors:  A Sommer; N R Miller; I Pollack; A E Maumenee; T George
Journal:  Arch Ophthalmol       Date:  1977-12

Review 9.  From ocular hypertension to ganglion cell death: a theoretical sequence of events leading to glaucoma.

Authors:  Robert W Nickells
Journal:  Can J Ophthalmol       Date:  2007-04       Impact factor: 1.882

10.  In-vivo imaging of retinal nerve fiber layer vasculature: imaging histology comparison.

Authors:  Drew Scoles; Daniel C Gray; Jennifer J Hunter; Robert Wolfe; Bernard P Gee; Ying Geng; Benjamin D Masella; Richard T Libby; Stephen Russell; David R Williams; William H Merigan
Journal:  BMC Ophthalmol       Date:  2009-08-23       Impact factor: 2.209

View more
  30 in total

1.  Postnatal maturation of the fovea in Macaca mulatta using optical coherence tomography.

Authors:  Nimesh B Patel; Li-Fang Hung; Ronald S Harwerth
Journal:  Exp Eye Res       Date:  2017-08-02       Impact factor: 3.467

2.  The photopic negative response of the flash electroretinogram in multiple sclerosis.

Authors:  Jing Wang; Han Cheng; Ying-Sheng Hu; Rosa A Tang; Laura J Frishman
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-03-09       Impact factor: 4.799

3.  The effects of graded intraocular pressure challenge on the optic nerve head.

Authors:  Nimesh Patel; Faith McAllister; Laura Pardon; Ronald Harwerth
Journal:  Exp Eye Res       Date:  2018-02-01       Impact factor: 3.467

4.  The non-human primate experimental glaucoma model.

Authors:  Claude F Burgoyne
Journal:  Exp Eye Res       Date:  2015-06-09       Impact factor: 3.467

Review 5.  Assessing retinal ganglion cell damage.

Authors:  C A Smith; J R Vianna; B C Chauhan
Journal:  Eye (Lond)       Date:  2017-01-13       Impact factor: 3.775

6.  Influence of anterior segment power on the scan path and RNFL thickness using SD-OCT.

Authors:  Nimesh B Patel; Brenda Garcia; Ronald S Harwerth
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-08-24       Impact factor: 4.799

7.  Relation between macular retinal ganglion cell/inner plexiform layer thickness and multifocal electroretinogram measures in experimental glaucoma.

Authors:  Xunda Luo; Nimesh B Patel; Lakshmi P Rajagopalan; Ronald S Harwerth; Laura J Frishman
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-06-26       Impact factor: 4.799

8.  Does optic nerve head size variation affect circumpapillary retinal nerve fiber layer thickness measurement by optical coherence tomography?

Authors:  David Huang; Vikas Chopra; Ake Tzu-Hui Lu; Ou Tan; Brian Francis; Rohit Varma
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-07-27       Impact factor: 4.799

9.  Optic disc area in different types of glaucoma.

Authors:  Oya Tekeli; Esra Savku; Ahmed Abdullayev
Journal:  Int J Ophthalmol       Date:  2016-08-18       Impact factor: 1.779

10.  Optical Coherence Tomography Segmentation Errors of the Retinal Nerve Fiber Layer Persist Over Time.

Authors:  Nisha Nagarkatti-Gude; Stuart K Gardiner; Brad Fortune; Shaban Demirel; Steven L Mansberger
Journal:  J Glaucoma       Date:  2019-05       Impact factor: 2.503

View more