Literature DB >> 21217439

Precision of lumbar intervertebral measurements: does a computer-assisted technique improve reliability?

Adam M Pearson1, Kevin F Spratt, James Genuario, William McGough, Katherine Kosman, Jon Lurie, Dilip K Sengupta.   

Abstract

STUDY
DESIGN: Comparison of intra- and interobserver reliability of digitized manual and computer-assisted intervertebral motion measurements and classification of "instability."
OBJECTIVE: To determine if computer-assisted measurement of lumbar intervertebral motion on flexion-extension radiographs improves reliability compared with digitized manual measurements. SUMMARY OF BACKGROUND DATA: Many studies have questioned the reliability of manual intervertebral measurements, although few have compared the reliability of computer-assisted and manual measurements on lumbar flexion-extension radiographs.
METHODS: Intervertebral rotation, anterior-posterior (AP) translation, and change in anterior and posterior disc height were measured with a digitized manual technique by three physicians and by three other observers using computer-assisted quantitative motion analysis (QMA) software. Each observer measured 30 sets of digital flexion-extension radiographs (L1-S1) twice. Shrout-Fleiss intraclass correlation coefficients for intra- and interobserver reliabilities were computed. The stability of each level was also classified (instability defined as >4 mm AP translation or 10° rotation), and the intra- and interobserver reliabilities of the two methods were compared using adjusted percent agreement (APA).
RESULTS: Intraobserver reliability intraclass correlation coefficients were substantially higher for the QMA technique THAN the digitized manual technique across all measurements: rotation 0.997 versus 0.870, AP translation 0.959 versus 0.557, change in anterior disc height 0.962 versus 0.770, and change in posterior disc height 0.951 versus 0.283. The same pattern was observed for interobserver reliability (rotation 0.962 vs. 0.693, AP translation 0.862 vs. 0.151, change in anterior disc height 0.862 vs. 0.373, and change in posterior disc height 0.730 vs. 0.300). The QMA technique was also more reliable for the classification of "instability." Intraobserver APAs ranged from 87 to 97% for QMA versus 60% to 73% for digitized manual measurements, while interobserver APAs ranged from 91% to 96% for QMA versus 57% to 63% for digitized manual measurements.
CONCLUSION: The use of QMA software substantially improved the reliability of lumbar intervertebral measurements and the classification of instability based on flexion-extension radiographs.

Entities:  

Mesh:

Year:  2011        PMID: 21217439     DOI: 10.1097/BRS.0b013e3181e11c13

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  12 in total

1.  Development of a novel radiographic measure of lumbar instability and validation using the facet fluid sign.

Authors:  John A Hipp; Richard D Guyer; Jack E Zigler; Donna D Ohnmeiss; Nicholas D Wharton
Journal:  Int J Spine Surg       Date:  2015-07-17

2.  Measurement Performance of a Computer Assisted Vertebral Motion Analysis System.

Authors:  Reginald J Davis; David C Lee; Chip Wade; Boyle Cheng
Journal:  Int J Spine Surg       Date:  2015-07-17

Review 3.  Do in vivo kinematic studies provide insight into adjacent segment degeneration? A qualitative systematic literature review.

Authors:  Masoud Malakoutian; David Volkheimer; John Street; Marcel F Dvorak; Hans-Joachim Wilke; Thomas R Oxland
Journal:  Eur Spine J       Date:  2015-06-09       Impact factor: 3.134

4.  Reproducibility and repeatability of a new computerized software for sagittal spinopelvic and scoliosis curvature radiologic measurements: Keops(®).

Authors:  C Maillot; E Ferrero; D Fort; C Heyberger; J-C Le Huec
Journal:  Eur Spine J       Date:  2015-02-28       Impact factor: 3.134

5.  Definition of Normal Vertebral Morphometry Using NHANES-II Radiographs.

Authors:  John A Hipp; Trevor F Grieco; Patrick Newman; Charles A Reitman
Journal:  JBMR Plus       Date:  2022-09-27

6.  Optimizing success with lumbar disc arthroplasty.

Authors:  Matthew F Gornet; Francine Schranck; Nicholas D Wharton; Douglas P Beall; Elizabeth Jones; Mark E Myers; John A Hipp
Journal:  Eur Spine J       Date:  2014-04-26       Impact factor: 3.134

7.  Preservation of Spine Motion in the Surgical Treatment of Adolescent Idiopathic Scoliosis Using an Innovative Apical Fusion Technique: A 2-Year Follow-Up Pilot Study.

Authors:  Pooria Hosseini; Allen Carl; Michael Grevitt; Colin Nnadi; Martin Repko; Dennis G Crandall; Ufuk Aydinli; Ľuboš Rehák; Martin Zabka; Steven Seme; Behrooz A Akbarnia
Journal:  Int J Spine Surg       Date:  2018-08-31

8.  Facet-sparing lumbar decompression with a minimally invasive flexible MicroBlade Shaver® versus traditional decompression: quantitative radiographic assessment.

Authors:  Carl Lauryssen; Sigurd Berven; Ronnie Mimran; Christopher Summa; Michael Sheinberg; Larry E Miller; Jon E Block
Journal:  Clin Interv Aging       Date:  2012-07-20       Impact factor: 4.458

9.  Relationships between Paraspinal Muscle Activity and Lumbar Inter-Vertebral Range of Motion.

Authors:  Alister du Rose; Alan Breen
Journal:  Healthcare (Basel)       Date:  2016-01-05

10.  Relationships between lumbar inter-vertebral motion and lordosis in healthy adult males: a cross sectional cohort study.

Authors:  Alister du Rose; Alan Breen
Journal:  BMC Musculoskelet Disord       Date:  2016-03-10       Impact factor: 2.362

View more