Literature DB >> 21205627

Complications related to less-invasive haemodynamic monitoring.

F J Belda1, G Aguilar, J L Teboul, D Pestaña, F J Redondo, M Malbrain, J C Luis, F Ramasco, A Umgelter, J Wendon, M Kirov, E Fernández-Mondéjar.   

Abstract

BACKGROUND: The aim of this study was to evaluate the type and incidence of complications during insertion, maintenance, and withdrawal of central arterial catheters used for transpulmonary thermodilution haemodynamic monitoring (PiCCO™).
METHODS: We conducted a prospective, observational, multicentre study in 14 European intensive care units (six countries). A total of 514 consecutive patients in whom haemodynamic monitoring by PiCCO™ was indicated were studied.
RESULTS: Five hundred and fourteen PiCCO catheters (475 in femoral, 26 in radial, nine in axillary, and four in brachial arteries) were inserted. Arterial access was obtained on the first attempt in 86.4% of the patients. Minor problems such as oozing after insertion (3.3%) or removal of the catheter (3.5%) were observed, but no episodes of serious bleeding (more than 50 ml) were recorded. Small local haematomas were observed after insertion (4.5%) and after removal (1.2%) of the catheter. These complications were not more frequent in patients with coagulation abnormalities. The incidence of site inflammation and catheter-related infection was 2% and 0.78%, respectively. Other complications such as ischaemia (0.4%), pulse loss (0.4%), or femoral artery thrombosis (0.2%) were rare, transient, and all resolved with catheter removal or embolectomy, respectively.
CONCLUSIONS: In this series of patients, central arterial catheters used for PiCCO™ monitoring were demonstrated to be a safe alternative for advanced haemodynamic monitoring.

Entities:  

Mesh:

Year:  2010        PMID: 21205627     DOI: 10.1093/bja/aeq377

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  23 in total

1.  Impact of misplaced subclavian vein catheter into jugular vein on transpulmonary thermodilution measurement variables.

Authors:  Wen-qiao Yu; Yun Zhang; Shao-yang Zhang; Zhong-yan Liang; Shui-qiao Fu; Jia Xu; Ting-bo Liang
Journal:  J Zhejiang Univ Sci B       Date:  2016-01       Impact factor: 3.066

Review 2.  Is there a role for invasive hemodynamic monitoring in acute heart failure management?

Authors:  Daniel De Backer
Journal:  Curr Heart Fail Rep       Date:  2015-06

3.  Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis.

Authors:  M Sanders; S Servaas; C Slagt
Journal:  J Clin Monit Comput       Date:  2019-06-07       Impact factor: 2.502

Review 4.  The transpulmonary thermodilution technique.

Authors:  Samir G Sakka; Daniel A Reuter; Azriel Perel
Journal:  J Clin Monit Comput       Date:  2012-07-18       Impact factor: 2.502

5.  Less invasive hemodynamic monitoring in critically ill patients.

Authors:  Jean-Louis Teboul; Bernd Saugel; Maurizio Cecconi; Daniel De Backer; Christoph K Hofer; Xavier Monnet; Azriel Perel; Michael R Pinsky; Daniel A Reuter; Andrew Rhodes; Pierre Squara; Jean-Louis Vincent; Thomas W Scheeren
Journal:  Intensive Care Med       Date:  2016-05-07       Impact factor: 17.440

Review 6.  Minimally invasive or noninvasive cardiac output measurement: an update.

Authors:  Lisa Sangkum; Geoffrey L Liu; Ling Yu; Hong Yan; Alan D Kaye; Henry Liu
Journal:  J Anesth       Date:  2016-03-09       Impact factor: 2.078

Review 7.  Alternatives to the Swan-Ganz catheter.

Authors:  Daniel De Backer; Jan Bakker; Maurizio Cecconi; Ludhmila Hajjar; Da Wei Liu; Suzanna Lobo; Xavier Monnet; Andrea Morelli; Sheila Neinan Myatra; Azriel Perel; Michael R Pinsky; Bernd Saugel; Jean-Louis Teboul; Antoine Vieillard-Baron; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2018-05-03       Impact factor: 17.440

Review 8.  Ultrasound-guided arterial catheterization.

Authors:  Sung-Ae Cho; Young-Eun Jang; Sang-Hwan Ji; Eun-Hee Kim; Ji-Hyun Lee; Hee-Soo Kim; Jin-Tae Kim
Journal:  Anesth Pain Med (Seoul)       Date:  2021-04-15

9.  Computed tomography to estimate cardiac preload and extravascular lung water. A retrospective analysis in critically ill patients.

Authors:  Bernd Saugel; Konstantin Holzapfel; Jens Stollfuss; Tibor Schuster; Veit Phillip; Caroline Schultheiss; Roland M Schmid; Wolfgang Huber
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2011-05-23       Impact factor: 2.953

10.  Effects of red blood cell transfusion on hemodynamic parameters: a prospective study in intensive care unit patients.

Authors:  Bernd Saugel; Michaela Klein; Alexander Hapfelmeier; Veit Phillip; Caroline Schultheiss; Agnes S Meidert; Marlena Messer; Roland M Schmid; Wolfgang Huber
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2013-03-25       Impact factor: 2.953

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.