Literature DB >> 26739527

Impact of misplaced subclavian vein catheter into jugular vein on transpulmonary thermodilution measurement variables.

Wen-qiao Yu1, Yun Zhang1, Shao-yang Zhang1, Zhong-yan Liang2, Shui-qiao Fu1, Jia Xu3, Ting-bo Liang1.   

Abstract

OBJECTIVE: The subclavian vein (SCV) is usually used to inject the indicator of cold saline for a transpulmonary thermodilution (TPTD) measurement. The SCV catheter being misplaced into the internal jugular (IJV) vein is a common occurrence. The present study explores the influence of a misplaced SCV catheter on TPTD variables.
METHODS: Thirteen severe acute pancreatitis (SAP) patients with malposition of the SCV catheter were enrolled in this study. TPTD variables including cardiac index (CI), global end-diastolic volume index (GEDVI), intrathoracic blood volume index (ITBVI), and extravascular lung water index (EVLWI) were obtained after injection of cold saline via the misplaced SCV catheter. Then, the misplaced SCV catheter was removed and IJV access was constructed for a further set of TPTD variables. Comparisons were made between the TPTD results measured through the IJV and misplaced SCV accesses.
RESULTS: A total of 104 measurements were made from TPTD curves after injection of cold saline via the IJV and misplaced SCV accesses. Bland-Altman analysis demonstrated an overestimation of +111.40 ml/m(2) (limits of agreement: 6.13 and 216.70 ml/m(2)) for GEDVI and ITBVI after a misplaced SCV injection. There were no significant influences on CI and EVLWI. The biases of +0.17 L/(min·m(2)) for CI and +0.17 ml/kg for EVLWI were revealed by Bland-Altman analysis.
CONCLUSIONS: The malposition of an SCV catheter does influence the accuracy of TPTD variables, especially GEDVI and ITBVI. The position of the SCV catheter should be confirmed by chest X-ray in order to make good use of the TPTD measurements.

Entities:  

Keywords:  Jugular vein catheter; Misplaced subclavian vein catheter; Severe acute pancreatitis; Transpulmonary thermodilution

Mesh:

Year:  2016        PMID: 26739527      PMCID: PMC4710841          DOI: 10.1631/jzus.B1500167

Source DB:  PubMed          Journal:  J Zhejiang Univ Sci B        ISSN: 1673-1581            Impact factor:   3.066


  25 in total

Review 1.  Complications related to less-invasive haemodynamic monitoring.

Authors:  F J Belda; G Aguilar; J L Teboul; D Pestaña; F J Redondo; M Malbrain; J C Luis; F Ramasco; A Umgelter; J Wendon; M Kirov; E Fernández-Mondéjar
Journal:  Br J Anaesth       Date:  2010-12-26       Impact factor: 9.166

2.  Bedside technique to detect misplaced subclavian vein catheter in internal jugular vein.

Authors:  Sanjay Goel; Manish Tandon; Bishnu Panigrahi
Journal:  Ann Card Anaesth       Date:  2010 Jan-Apr

3.  Guidelines for the prevention of intravascular catheter-related infections.

Authors:  Naomi P O'Grady; Mary Alexander; Lillian A Burns; E Patchen Dellinger; Jeffrey Garland; Stephen O Heard; Pamela A Lipsett; Henry Masur; Leonard A Mermel; Michele L Pearson; Issam I Raad; Adrienne G Randolph; Mark E Rupp; Sanjay Saint
Journal:  Clin Infect Dis       Date:  2011-04-01       Impact factor: 9.079

4.  Transpulmonary thermodilution using femoral indicator injection: a prospective trial in patients with a femoral and a jugular central venous catheter.

Authors:  Bernd Saugel; Andreas Umgelter; Tibor Schuster; Veit Phillip; Roland M Schmid; Wolfgang Huber
Journal:  Crit Care       Date:  2010-05-25       Impact factor: 9.097

Review 5.  Transpulmonary dilution-derived extravascular lung water as a measure of lung edema.

Authors:  Saheed Khan; Ronald J Trof; A B Johan Groeneveld
Journal:  Curr Opin Crit Care       Date:  2007-06       Impact factor: 3.687

Review 6.  How to measure and interpret volumetric measures of preload.

Authors:  Giorgio Della Rocca; Maria Gabriella Costa; Paolo Pietropaoli
Journal:  Curr Opin Crit Care       Date:  2007-06       Impact factor: 3.687

7.  Saline flush test for bedside detection of misplaced subclavian vein catheter into ipsilateral internal jugular vein.

Authors:  G P Rath; P K Bithal; G R Toshniwal; H Prabhakar; H H Dash
Journal:  Br J Anaesth       Date:  2009-02-25       Impact factor: 9.166

8.  Validation of a new transpulmonary thermodilution system to assess global end-diastolic volume and extravascular lung water.

Authors:  Karim Bendjelid; Raphael Giraud; Nils Siegenthaler; Frederic Michard
Journal:  Crit Care       Date:  2010-11-23       Impact factor: 9.097

9.  Hemodynamic monitoring and management in patients undergoing high risk surgery: a survey among North American and European anesthesiologists.

Authors:  Maxime Cannesson; Gunther Pestel; Cameron Ricks; Andreas Hoeft; Azriel Perel
Journal:  Crit Care       Date:  2011-08-15       Impact factor: 9.097

Review 10.  Clinical review: Update on hemodynamic monitoring--a consensus of 16.

Authors:  Jean-Louis Vincent; Andrew Rhodes; Azriel Perel; Greg S Martin; Giorgio Della Rocca; Benoit Vallet; Michael R Pinsky; Christoph K Hofer; Jean-Louis Teboul; Willem-Pieter de Boode; Sabino Scolletta; Antoine Vieillard-Baron; Daniel De Backer; Keith R Walley; Marco Maggiorini; Mervyn Singer
Journal:  Crit Care       Date:  2011-08-18       Impact factor: 9.097

View more
  5 in total

1.  Femoral indicator injection for transpulmonary thermodilution using the EV1000/VolumeView(®): do the same criteria apply as for the PiCCO(®)?

Authors:  Wolfgang Huber; Veit Phillip; Josef Höllthaler; Caroline Schultheiss; Bernd Saugel; Roland M Schmid
Journal:  J Zhejiang Univ Sci B       Date:  2016-07       Impact factor: 3.066

2.  Mandatory criteria for the application of variability-based parameters of fluid responsiveness: a prospective study in different groups of ICU patients.

Authors:  Wolfgang Huber; Uli Mayr; Andreas Umgelter; Michael Franzen; Wolfgang Reindl; Roland M Schmid; Florian Eckel
Journal:  J Zhejiang Univ Sci B       Date:  2018-07       Impact factor: 3.066

3.  Transpulmonary thermodilution in patients treated with veno-venous extracorporeal membrane oxygenation.

Authors:  Gregor Loosen; Alice Marguerite Conrad; Michael Hagman; Nils Essert; Manfred Thiel; Thomas Luecke; Joerg Krebs
Journal:  Ann Intensive Care       Date:  2021-07-02       Impact factor: 6.925

4.  Comparison of cardiac function index derived from femoral and jugular indicator injection for transpulmonary thermodilution with the PiCCO-device: A prospective observational study.

Authors:  Alexander Herner; Markus Heilmaier; Ulrich Mayr; Roland M Schmid; Wolfgang Huber
Journal:  PLoS One       Date:  2018-07-31       Impact factor: 3.240

5.  Comparison of pulmonary vascular permeability index PVPI and global ejection fraction GEF derived from jugular and femoral indicator injection using the PiCCO-2 device: A prospective observational study.

Authors:  Wolfgang Huber; Andrea Gruber; Maximilian Eckmann; Felicia Elkmann; Ines Klein; Tobias Lahmer; Ulrich Mayr; Raphael Schellnegger; Jochen Schneider; Gonzalo Batres-Baires; Lisa Fekecs; Analena Beitz; Helena Berbara; Roland Schmid; Alexander Herner
Journal:  PLoS One       Date:  2017-10-17       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.