Literature DB >> 21184548

Recurrent stent fracture in the right coronary artery.

Adnan K Chhatriwalla1, Samuel Unzek, Samir R Kapadia.   

Abstract

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21184548      PMCID: PMC6653174          DOI: 10.1002/clc.20739

Source DB:  PubMed          Journal:  Clin Cardiol        ISSN: 0160-9289            Impact factor:   2.882


× No keyword cloud information.
  9 in total

1.  Stent fracture and restenosis in the drug-eluting stent era.

Authors:  Georgios Sianos; Sjoerd Hofma; Jurgen M R Ligthart; Francesco Saia; Angela Hoye; Pedro A Lemos; Patrick W Serruys
Journal:  Catheter Cardiovasc Interv       Date:  2004-01       Impact factor: 2.692

2.  Images in clinical medicine. Coronary-stent fracture.

Authors:  Pertha S Chowdhury; Renato G Ramos
Journal:  N Engl J Med       Date:  2002-08-22       Impact factor: 91.245

3.  Drug-eluting stent fracture occurred within 2 days after stent implantation.

Authors:  Won Yu Kang; Weon Kim; Han Gyun Kim; Wan Kim
Journal:  Int J Cardiol       Date:  2006-11-13       Impact factor: 4.164

Review 4.  Coronary stent fracture in a saphenous vein graft to right coronary artery--successful treatment by the novel use of the Jomed coronary stent graft: case report and review of the literature.

Authors:  T W Koh; A Mathur
Journal:  Int J Cardiol       Date:  2007-04-27       Impact factor: 4.164

5.  Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk.

Authors:  Michael Joner; Aloke V Finn; Andrew Farb; Erik K Mont; Frank D Kolodgie; Elena Ladich; Robert Kutys; Kristi Skorija; Herman K Gold; Renu Virmani
Journal:  J Am Coll Cardiol       Date:  2006-05-05       Impact factor: 24.094

6.  Stent fracture and restenosis of a paclitaxel-eluting stent.

Authors:  Michalis I Hamilos; Michail I Papafaklis; Jurgen M Ligthart; Patrick W Serruys; Georgios Sianos
Journal:  Hellenic J Cardiol       Date:  2005 Nov-Dec

Review 7.  Incomplete neointimal coverage of sirolimus-eluting stents: angioscopic findings.

Authors:  Jun-ichi Kotani; Masaki Awata; Shinsuke Nanto; Masaaki Uematsu; Fusako Oshima; Hitoshi Minamiguchi; Gary S Mintz; Seiki Nagata
Journal:  J Am Coll Cardiol       Date:  2006-04-04       Impact factor: 24.094

Review 8.  Drug-eluting stent fracture and acute coronary syndrome.

Authors:  Adnan K Chhatriwalla; Akin Cam; Samuel Unzek; Deepak L Bhatt; Russell E Raymond; A Michael Lincoff; Patrick L Whitlow; Stephen G Ellis; E Murat Tuzcu; Samir R Kapadia
Journal:  Cardiovasc Revasc Med       Date:  2009 Jul-Sep

9.  Incidence and predictors of drug-eluting stent fracture in human coronary artery a pathologic analysis.

Authors:  Gaku Nakazawa; Aloke V Finn; Marc Vorpahl; Elena Ladich; Robert Kutys; Isidora Balazs; Frank D Kolodgie; Renu Virmani
Journal:  J Am Coll Cardiol       Date:  2009-11-17       Impact factor: 24.094

  9 in total
  3 in total

1.  Two cases of immediate stent fracture after zotarolimus-eluting stent implantation.

Authors:  Pil Hyung Lee; Seung-Whan Lee; Jong-Young Lee; Young-Hak Kim; Cheol Whan Lee; Duk-Woo Park; Seong-Wook Park; Seung-Jung Park
Journal:  Korean Circ J       Date:  2015-01-26       Impact factor: 3.243

2.  A case report of spontaneous coronary artery dissection complicated by stent fracture.

Authors:  Hanxiang Gao; Ye Hu; Qi Li; Suyu Yao; Zheng Zhang; Ming Bai
Journal:  Medicine (Baltimore)       Date:  2019-08       Impact factor: 1.817

3.  Stent fracture: how frequently is it recognized?

Authors:  Mohammed Khalil Mohsen; Awad Alqahtani; Jassim Al Suwaidi
Journal:  Heart Views       Date:  2013-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.