OBJECTIVES: The goal of this study was to use angioscopy to investigate the amount of neointimal coverage after sirolimus-eluting stent (SES) implantation. BACKGROUND: Sirolimus-eluting stents reduce intimal hyperplasia. METHODS: We used angioscopy to evaluate 37 consecutive stented coronary artery lesions (15 SES and 22 bare-metal stents [BMS]) in 25 patients (18 men, 7 women) at 3 to 6 months after stent implantation. Angioscopic evaluation focused on: 1) neointimal coverage of stent struts, and 2) the existence of thrombi. The degree of neointimal coverage was classified as grade 0 when there was no neointimal coverage (similar to immediately after the implantation); grade 1 when stent struts bulged into the lumen, but were covered and still translucently visible; grade 2 when stent struts were visible but not clearly seen (not translucent); and grade 3 when stent struts were not visible because they were embedded in the neointima. RESULTS: Thrombi were identified in eight stented segments, tended to be more common with SES (p = 0.14), but were not seen on angiography. Three of the 15 SES (20%) had grade 0 neointimal coverage, and only 2 SES (13.3%) had complete coverage (grades 2/3). In contrast, all 22 BMS showed complete intimal coverage (grades 2/3). Thrombi were more common in stents with incomplete neointimal coverage (p = 0.09). CONCLUSIONS: The SES had incomplete neointimal coverage three to six months after implantation, and this was associated with subclinical thrombus formation.
OBJECTIVES: The goal of this study was to use angioscopy to investigate the amount of neointimal coverage after sirolimus-eluting stent (SES) implantation. BACKGROUND:Sirolimus-eluting stents reduce intimal hyperplasia. METHODS: We used angioscopy to evaluate 37 consecutive stented coronary artery lesions (15 SES and 22 bare-metal stents [BMS]) in 25 patients (18 men, 7 women) at 3 to 6 months after stent implantation. Angioscopic evaluation focused on: 1) neointimal coverage of stent struts, and 2) the existence of thrombi. The degree of neointimal coverage was classified as grade 0 when there was no neointimal coverage (similar to immediately after the implantation); grade 1 when stent struts bulged into the lumen, but were covered and still translucently visible; grade 2 when stent struts were visible but not clearly seen (not translucent); and grade 3 when stent struts were not visible because they were embedded in the neointima. RESULTS:Thrombi were identified in eight stented segments, tended to be more common with SES (p = 0.14), but were not seen on angiography. Three of the 15 SES (20%) had grade 0 neointimal coverage, and only 2 SES (13.3%) had complete coverage (grades 2/3). In contrast, all 22 BMS showed complete intimal coverage (grades 2/3). Thrombi were more common in stents with incomplete neointimal coverage (p = 0.09). CONCLUSIONS: The SES had incomplete neointimal coverage three to six months after implantation, and this was associated with subclinical thrombus formation.
Authors: Ai-Ling Lin; Wei Zheng; Jonathan J Halloran; Raquel R Burbank; Stacy A Hussong; Matthew J Hart; Martin Javors; Yen-Yu Ian Shih; Eric Muir; Rene Solano Fonseca; Randy Strong; Arlan G Richardson; James D Lechleiter; Peter T Fox; Veronica Galvan Journal: J Cereb Blood Flow Metab Date: 2013-06-26 Impact factor: 6.200