Literature DB >> 21183540

Extremity and eye lens doses in interventional radiology and cardiology procedures: first results of the ORAMED project.

J Domienik1, M Brodecki, E Carinou, L Donadille, J Jankowski, C Koukorava, S Krim, D Nikodemova, N Ruiz-Lopez, M Sans-Mercé, L Struelens, F Vanhavere.   

Abstract

The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.

Entities:  

Mesh:

Year:  2010        PMID: 21183540     DOI: 10.1093/rpd/ncq508

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  10 in total

1.  Occupational radiation dose to eyes from interventional radiology procedures in light of the new eye lens dose limit from the International Commission on Radiological Protection.

Authors:  U O'Connor; C Walsh; A Gallagher; A Dowling; M Guiney; J M Ryan; N McEniff; G O'Reilly
Journal:  Br J Radiol       Date:  2015-03-11       Impact factor: 3.039

Review 2.  Occupational exposure to low doses of ionizing radiation and cataract development: a systematic literature review and perspectives on future studies.

Authors:  Gaël P Hammer; Ulrike Scheidemann-Wesp; Florence Samkange-Zeeb; Henryk Wicke; Kazuo Neriishi; Maria Blettner
Journal:  Radiat Environ Biophys       Date:  2013-06-27       Impact factor: 1.925

3.  Effects of chronic low-dose exposure to ionizing radiation on physician microvascular structure revealed by nail fold capillaroscopy.

Authors:  Pascal Wild; Christine Gauron; Karine Champion; Pascal Cohen; Caroline Menez; Anne-Sophie Tellart; Hélène Thiel; Michel Grzebyk; Raffaele Pennarola; Dominique Choudat
Journal:  Radiat Environ Biophys       Date:  2015-12-28       Impact factor: 1.925

Review 4.  Eye protection in interventional procedures.

Authors:  Beth A Schueler; Kenneth A Fetterly
Journal:  Br J Radiol       Date:  2021-10-01       Impact factor: 3.629

5.  Quantitative evaluation of light scattering intensities of the crystalline lens for radiation related minimal change in interventional radiologists: a cross-sectional pilot study.

Authors:  Toshi Abe; Shigeru Furui; Hiroshi Sasaki; Yasuo Sakamoto; Shigeru Suzuki; Tatsuya Ishitake; Kinuyo Terasaki; Hiroshi Kohtake; Alexander M Norbash; Richard H Behrman; Naofumi Hayabuchi
Journal:  J Radiat Res       Date:  2012-11-09       Impact factor: 2.724

6.  Radiation-induced noncancer risks in interventional cardiology: optimisation of procedures and staff and patient dose reduction.

Authors:  Zhonghua Sun; Aini AbAziz; Ahmad Khairuddin Md Yusof
Journal:  Biomed Res Int       Date:  2013-08-20       Impact factor: 3.411

7.  Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters.

Authors:  Qianjun Jia; Ziman Chen; Xianxian Jiang; Zhenjun Zhao; Meiping Huang; Jiahua Li; Jian Zhuang; Xiaoqing Liu; Tianyu Hu; Wensheng Liang
Journal:  Sci Rep       Date:  2017-02-07       Impact factor: 4.379

8.  Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring.

Authors:  Anna M Sailer; Laura Vergoossen; Leonie Paulis; Willem H van Zwam; Marco Das; Joachim E Wildberger; Cécile R L P N Jeukens
Journal:  Cardiovasc Intervent Radiol       Date:  2017-05-12       Impact factor: 2.740

Review 9.  Radiation protection in the cardiac catheterization laboratory.

Authors:  Sylvia Marie R Biso; Mladen I Vidovich
Journal:  J Thorac Dis       Date:  2020-04       Impact factor: 3.005

10.  Assessment of eye doses to staff involved in interventional cardiology procedures in Kuwait.

Authors:  Meshari Alnaaimi; Mousa Alduaij; Faisal Shenawy; Musab Algaily; Talal Mohammedzein; Mohamed Shaaban; Madan M Rehani
Journal:  Radiat Environ Biophys       Date:  2021-08-05       Impact factor: 1.925

  10 in total