PURPOSE: To assess the benefits of intraocular lens (IOL)-constant optimization for IOLMaster biometry on refractive outcomes after cataract surgery for all surgeons and individual surgeons, define acceptable levels of error in IOL-constant optimization, and calculate the minimum number of eyes required for IOL-constant optimization.
SETTING: Department of Ophthalmology, Gloucestershire Hospitals NHS Foundation Trust, Cheltenham, United Kingdom.
DESIGN: Database study.
METHODS: Hypothetical prediction errors were retrospectively calculated on prospectively collected data extracted from electronic medical records using manufacturers' and optimized IOL constants with Hoffer Q, Holladay 1, and SRK/T formulas for 2 IOLs. The acceptable IOL-constant optimization error margins, personalized IOL constants for individual surgeons, and minimum sample sizes for IOL-constant optimization were evaluated.
RESULTS: Optimization of IOL constants reduced the mean absolute errors from 0.66 diopters (D) and 0.52 D to 0.40 D and 0.42 D for the Sofport AO IOL and Akreos Fit IOL, respectively. The percentage of eyes within ±0.25 D, ±0.50 D, and ±1.00 D of target refraction improved from for both IOL models. The IOL-constant errors exceeding 0.09 for the Hoffer Q, 0.09 for the Holladay 1, and 0.15 for the SRK/T produced inferior outcomes. Differences in personalized IOL constants between most surgeons were clinically insignificant. Calculating IOL constants to within 0.06, 0.06, and 0.10 for the Hoffer Q, Holladay 1, and SRK/T, respectively, required 148 to 257 eyes.
CONCLUSIONS: Optimizing IOL constants for IOLMaster biometry substantially improved refractive outcomes, far exceeding any additional benefit of personalizing IOL constants for individual surgeons. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned. Additional disclosure is found in the footnotes.
Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21183099     DOI: 10.1016/j.jcrs.2010.07.037

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  27 in total

1.  Cataract update.

Authors:  Ali A Al-Rajhi
Journal:  Saudi J Ophthalmol       Date:  2012-01

2.  The effect of head tilt on keratometric measurement using the IOLMaster.

Authors:  C Y Park; J R Do; S H Kim; C-Y Lim; R S Chuck
Journal:  Eye (Lond)       Date:  2013-09-20       Impact factor: 3.775

3.  Impact of constant optimization of formulae.

Authors:  Virgilio Galvis; Alejandro Tello; Judith Portorreal
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-05-22       Impact factor: 3.117

4.  Errors associated with IOLMaster biometry as a function of internal ocular dimensions.

Authors:  Miguel Faria-Ribeiro; Daniela Lopes-Ferreira; Norberto López-Gil; Jorge Jorge; José Manuel González-Méijome
Journal:  J Optom       Date:  2014-01-28

5.  Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgery.

Authors:  Sabong Srivannaboon; Chareenun Chirapapaisan
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-09-05       Impact factor: 3.117

Review 6.  Optimising biometry for best outcomes in cataract surgery.

Authors:  R Sheard
Journal:  Eye (Lond)       Date:  2013-12-06       Impact factor: 3.775

7.  Comparison of intraocular lens power prediction using immersion ultrasound and optical biometry with and without formula optimization.

Authors:  Gabor Nemeth; Attila Nagy; Andras Berta; Laszlo Modis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-04-13       Impact factor: 3.117

8.  Optimization of intraocular lens constant improves refractive outcomes in combined endothelial keratoplasty and cataract surgery.

Authors:  Gustavo Bonfadini; John G Ladas; Hamilton Moreira; Mauro Campos; Mario Matthaei; Beatriz Muñoz; Kim Pratzer; Albert S Jun
Journal:  Ophthalmology       Date:  2012-10-27       Impact factor: 12.079

9.  Accuracy of Holladay 2 formula using IOLMaster parameters in the absence of lens thickness value.

Authors:  Sabong Srivannaboon; Chareenun Chirapapaisan; Niphon Chirapapaisan; Buntitar Lertsuwanroj; Mathinee Chongchareon
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-08-15       Impact factor: 3.117

10.  IOL Formula Constants: Strategies for Optimization and Defining Standards for Presenting Data.

Authors:  Achim Langenbucher; Nóra Szentmáry; Alan Cayless; Michael Müller; Timo Eppig; Simon Schröder; Ekkehart Fabian
Journal:  Ophthalmic Res       Date:  2021-02-02       Impact factor: 2.892

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.