Literature DB >> 21167704

An aptamer-based chromatographic strip assay for sensitive toxin semi-quantitative detection.

Libing Wang1, Wenwei Ma, Wei Chen, Liqiang Liu, Wei Ma, Yingyue Zhu, Liguang Xu, Hua Kuang, Chuanlai Xu.   

Abstract

An aptamer-based chromatographic strip assay method for rapid toxin detection was developed. The aptamer-based strip assay was based on the competition for the aptamer between ochratoxin A and DNA probes. The sensing results indicated that the sensitivity of the aptamer-based strip was better than that of conventional antibody-based strips. The visual limit of detection of the strip for qualitative detection was 1 ng/mL while the LOD for semi-quantitative detection could down to 0.18 ng/mL by using scanning reader. The recoveries of test samples were from 96% to 110%. All detections could be achieved in less than 10 min, indicating that the aptamer-based strip could be a potential useful tool for rapid on-site detections.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21167704     DOI: 10.1016/j.bios.2010.11.040

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  21 in total

1.  Detection of ochratoxin A by quantum dots-based fluorescent immunochromatographic assay.

Authors:  Jingming Zhou; Qingbao Yang; Chao Liang; Yumei Chen; Xiaoli Zhang; Zhanxiang Liu; Aiping Wang
Journal:  Anal Bioanal Chem       Date:  2020-10-16       Impact factor: 4.142

2.  Recent trends in SELEX technique and its application to food safety monitoring.

Authors:  Jingjing Wu; Yingyue Zhu; Feng Xue; Zhanlong Mei; Li Yao; Xin Wang; Lei Zheng; Jian Liu; Guodong Liu; Chifang Peng; Wei Chen
Journal:  Mikrochim Acta       Date:  2014-04       Impact factor: 5.833

Review 3.  Nanomaterial-based aptamer biosensors for ochratoxin A detection: a review.

Authors:  Xiujin Chen; Dong Gao; Zhaozhou Li; Yao Wang; Fengxia Sun; Caixia Qiu; Kaifeng He; Jing Wang
Journal:  Anal Bioanal Chem       Date:  2022-03-16       Impact factor: 4.142

4.  A paper electrode integrated lateral flow immunosensor for quantitative analysis of oxidative stress induced DNA damage.

Authors:  Xuena Zhu; Pratikkumar Shah; Susan Stoff; Hongyun Liu; Chen-zhong Li
Journal:  Analyst       Date:  2014-06-07       Impact factor: 4.616

5.  A test strip for ochratoxin A based on the use of aptamer-modified fluorescence upconversion nanoparticles.

Authors:  Shijia Wu; Lihong Liu; Nuo Duan; Wenyue Wang; Qianru Yu; Zhouping Wang
Journal:  Mikrochim Acta       Date:  2018-10-05       Impact factor: 5.833

6.  Development of an immunochromatographic strip for rapid detection of Pantoea stewartii subsp. stewartii.

Authors:  Min Feng; Dezhao Kong; Wenbing Wang; Liqiang Liu; Shanshan Song; Chuanlai Xu
Journal:  Sensors (Basel)       Date:  2015-02-12       Impact factor: 3.576

Review 7.  Single-Stranded DNA Aptamers against Pathogens and Toxins: Identification and Biosensing Applications.

Authors:  Ka Lok Hong; Letha J Sooter
Journal:  Biomed Res Int       Date:  2015-06-23       Impact factor: 3.411

8.  Recent advances and achievements in nanomaterial-based, and structure switchable aptasensing platforms for ochratoxin A detection.

Authors:  Akhtar Hayat; Cheng Yang; Amina Rhouati; Jean Louis Marty
Journal:  Sensors (Basel)       Date:  2013-11-06       Impact factor: 3.576

9.  Challenges and opportunities for small molecule aptamer development.

Authors:  Maureen McKeague; Maria C Derosa
Journal:  J Nucleic Acids       Date:  2012-10-24

10.  A simple and sensitive approach for ochratoxin A detection using a label-free fluorescent aptasensor.

Authors:  Zhenzhen Lv; Ailiang Chen; Jinchuan Liu; Zheng Guan; Yu Zhou; Siyuan Xu; Shuming Yang; Cheng Li
Journal:  PLoS One       Date:  2014-01-21       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.