Literature DB >> 21166827

Accuracy of the iPex multi-frequency electronic apex locator in primary molars: an ex vivo study.

P Nelson-Filho1, P C Romualdo, K C Bonifácio, M R Leonardo, R A B Silva, L A B Silva.   

Abstract

AIM: To evaluate ex vivo the accuracy of the iPex multi-frequency electronic apex locator (NSK Ltd, Tokyo, Japan) for working length determination in primary molar teeth.
METHODOLOGY: One calibrated examiner determined the working length in 20 primary molar teeth (total of 33 root canals). Working length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the most coronal limit of root resorption, and electronically using the electronic apex locator iPex, according to the manufacturers' instructions. Data were analysed statistically using the intraclass correlation (ICC) test.
RESULTS: Comparison of the actual and the electronic measurements revealed high correlation (ICC = 0.99) between the methods, regardless of the presence or absence of physiological root resorption.
CONCLUSIONS: In this laboratory study, the iPex accurately identified the apical foramen or the apical opening location for working length measurement in primary molar teeth.
© 2010 International Endodontic Journal.

Entities:  

Mesh:

Year:  2010        PMID: 21166827     DOI: 10.1111/j.1365-2591.2010.01827.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  8 in total

1.  Formulating a regression equation for determination of working length in primary molars using apex locators: a clinical study.

Authors:  A Dandempally; R Muppa; M K Duddu; P Bhupatiraju; S Nallanchakrava
Journal:  Eur Arch Paediatr Dent       Date:  2013-06-18

2.  Evaluation of the multifrequency electronic apex locator Joypex 5 in primary teeth.

Authors:  E J N L Silva; D R Herrera; E J Souza-Júnior; T P Rosa
Journal:  Eur Arch Paediatr Dent       Date:  2013-07-24

3.  In vitro comparison between apex locators, direct and radiographic techniques for determining the root canal length in primary teeth.

Authors:  L Z Adriano; J C Barasuol; M Cardoso; M Bolan
Journal:  Eur Arch Paediatr Dent       Date:  2019-01-02

4.  Accuracy of five electronic foramen locators with different operating systems: an ex vivo study.

Authors:  Bruno Carvalho de Vasconcelos; Michelli de Medeiros Bueno; Suyane Maria Luna-Cruz; Marco Antonio Hungaro Duarte; Carlos Augusto de Oliveira Fernandes
Journal:  J Appl Oral Sci       Date:  2013 Mar-Apr       Impact factor: 2.698

5.  Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.

Authors:  Pil-Jong Kim; Hong-Gee Kim; Byeong-Hoon Cho
Journal:  Restor Dent Endod       Date:  2014-12-26

6.  Accuracy of an Electronic Apex Locator for Working Length Determination in Primary Anterior Teeth.

Authors:  Zahra Bahrololoomi; Ali Asghar Soleymani; Jalil Modaresi; Mahsa Imanian; Malihe Lotfian
Journal:  J Dent (Tehran)       Date:  2015-04

7.  A smart rotary technique versus conventional pulpectomy for primary teeth: A randomized controlled clinical study.

Authors:  Negar Mokhtari; Alireza-Sarraf Shirazi; Masoumeh Ebrahimi
Journal:  J Clin Exp Dent       Date:  2017-11-01

8.  A Comparative Evaluation of Accuracy of New-generation Electronic Apex Locator with Conventional Radiography to determine Working Length in Primary Teeth: An in vivo Study.

Authors:  K Vidya Bhat; Prakashchandra Shetty; Latha Anandakrishna
Journal:  Int J Clin Pediatr Dent       Date:  2017-02-27
  8 in total