| Literature DB >> 21165182 |
Seung-Ryong Ha1, Jae-Ho Yang, Jai-Bong Lee, Jung-Suk Han, Sung-Hun Kim.
Abstract
PURPOSE: The purpose of this study was to investigate the diametral tensile strength of polymer-based temporary crown and fixed partial denture (FPD) materials, and the change of the diametral tensile strength with time.Entities:
Keywords: Diametral tensile strength; Polymer-based temporary crown and fixed partial denture materials
Year: 2010 PMID: 21165182 PMCID: PMC2984512 DOI: 10.4047/jap.2010.2.1.14
Source DB: PubMed Journal: J Adv Prosthodont ISSN: 2005-7806 Impact factor: 1.904
The materials investigated in this study
Fig. 1Dimension of cylinder-shaped specimen. φ = 4 mm, L = 6 mm, P = load.
Means and standard deviation in parenthesis of diametral tensile strength of the materials investigated
One-way ANOVA test of the diametral tensile strengths of materials investigated at each time
Independent sample t test of the diametral tensile strengths of each material investigated between 5 min and 1 h
X Shaded cell denotes significant differences between two groups at P < .05.
Multiple comparison Scheffé test of the diametral tensile strengths between materials at each time
X Shaded cell denotes significant differences between two groups at P < .05.