Literature DB >> 21163600

Triple-rule-out dual-source CT angiography of patients with acute chest pain: dose reduction potential of 100 kV scanning.

Radko Krissak1, Thomas Henzler, Anne Prechel, Miriam Reichert, Joachim Gruettner, Tim Sueselbeck, Stefan O Schoenberg, Christian Fink.   

Abstract

PURPOSE: To investigate the dose reduction potential of low kV triple-rule-out dual-source CT angiography (TRO-CTA) in non-obese (BMI ≤ 25 kg/m(2)) patients with acute chest pain.
MATERIALS AND METHODS: Sixty consecutive patients were randomly assigned to two different retrospectively ECG-gated TRO-CTA protocols in this prospective trial: Thirty patients were examined with a 120-kV standard protocol (320 reference mAs with automatic tube current modulation, automatically adapted pitch and ECG-pulsing) and served as the control group (group 1), an otherwise identical 100 kV protocol was used in the other thirty patients (group 2) for a radiation dose reduction. Subjective image quality was assessed on a 5 point scale (1: excellent, 5: non-diagnostic) by two blinded observers. Quantitative image analysis assessed vascular attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in different vascular segments. The effective dose was calculated from the dose length product (DLP) using a conversion coefficient of 0.017 mSvmGy(-1)cm(-1).
RESULTS: There was no significant difference of age, BMI, heart rate, pitch or scan length between both patient groups. Subjective image quality was rated similar in both groups (group 1: 1.2 ± 0.4, group 2: average score=1.3 ± 0.5). Vessel attenuation was significantly higher in group 2 than in group 1 (ascending aorta: 456 ± 83 HU vs. 370 ± 78 HU, p<0.001; pulmonary artery: 468 ± 118 HU vs. 411 ± 91 HU, p=0.03; left coronary artery: 437 ± 110 HU vs. 348 ± 89 HU, p<0.001), however, there was no significant difference in SNR (13.2 ± 7.6 vs. 14.5 ± 7.5, p=0.49) or CNR (13.8 ± 6.6 vs. 15.9 ± 7.7, p=0.25). The effective radiation dose of the 100 kV protocol was significantly lower (9.6 ± 3.2 mSv vs. 18.1 ± 9.4 mSv, p<0.0001).
CONCLUSION: TRO-CTA with 100 kV is feasible in non-obese patients and results in diagnostic image quality and significantly reduced radiation dose.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21163600     DOI: 10.1016/j.ejrad.2010.11.021

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  9 in total

1.  Prospective ECG-gated 320-row CT angiography of the whole aorta and coronary arteries.

Authors:  Yu Li; Zhanming Fan; Lei Xu; Lin Yang; Haiyan Xin; Nan Zhang; Zhaoqi Zhang
Journal:  Eur Radiol       Date:  2012-06-04       Impact factor: 5.315

2.  Triple-rule-out CT angiography using two axial scans with 16 cm wide-detector for radiation dose reduction.

Authors:  Yuhuan Chen; Qi Wang; Jianying Li; Yongjun Jia; Qi Yang; Taiping He
Journal:  Eur Radiol       Date:  2018-05-22       Impact factor: 5.315

3.  [Possibilities for exposure reduction in computed tomography examination of acute chest pain].

Authors:  H-C Becker
Journal:  Radiologe       Date:  2012-10       Impact factor: 0.635

4.  Triple rule-out acute chest pain evaluation using a 320-row-detector volume CT: a comparison of the wide-volume and helical modes.

Authors:  Eun-Ju Kang; Ki-Nam Lee; Dong Won Kim; Bo Sung Kim; Sunseob Choi; Byeong-Ho Park; Jong Young Oh
Journal:  Int J Cardiovasc Imaging       Date:  2012-05-23       Impact factor: 2.357

5.  Abdominal aortic intimal flap motion characterization in acute aortic dissection: assessed with retrospective ECG-gated thoracoabdominal aorta dual-source CT angiography.

Authors:  Shifeng Yang; Xia Li; Baoting Chao; Lebin Wu; Zhaoping Cheng; Yanhua Duan; Dawei Wu; Yiqiang Zhan; Jiuhong Chen; Bo Liu; Xiaopeng Ji; Pei Nie; Ximing Wang
Journal:  PLoS One       Date:  2014-02-04       Impact factor: 3.240

6.  Comparison of Chest Pain Protocols for Electrocardiography-Gated Dual-Source Cardiothoracic CT in Children and Adults: The Effect of Tube Current Saturation on Radiation Dose Reduction.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2018-01-02       Impact factor: 3.500

Review 7.  Clinical Applications of Wide-Detector CT Scanners for Cardiothoracic Imaging: An Update.

Authors:  Eun Ju Kang
Journal:  Korean J Radiol       Date:  2019-12       Impact factor: 3.500

8.  Diagnostic accuracy and clinical outcomes of ECG-gated, whole chest CT in the emergency department.

Authors:  Kelley R Branch; Jared Strote; William P Shuman; Lee M Mitsumori; Janet M Busey; Tessa Rue; James H Caldwell
Journal:  PLoS One       Date:  2013-04-16       Impact factor: 3.240

9.  Low-tube-voltage selection for triple-rule-out CTA: relation to patient size.

Authors:  Richard A P Takx; Radko Krissak; Christian Fink; Valentin Bachmann; Thomas Henzler; Mathias Meyer; John W Nance; Stefan O Schoenberg; Paul Apfaltrer
Journal:  Eur Radiol       Date:  2016-09-29       Impact factor: 5.315

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.