Literature DB >> 21160587

Role of three-dimensional imaging integration in atrial fibrillation ablation.

Roberto De Ponti1, Raffaella Marazzi, Domenico Lumia, Giuseppe Picciolo, Roberto Biddau, Carlo Fugazzola, Jorge A Salerno-Uriarte.   

Abstract

Atrial fibrillation is the most common arrhythmia and in symptomatic patients with a drug-refractory form, catheter ablation aimed at electrically disconnecting the pulmonary veins (PVs) has proved more effective than use of antiarrhythmic drugs in maintaining sinus rhythm during follow-up. On the other hand, this ablation procedure is complex, requires specific training and adequate clinical experience. A main challenge is represented by the need for accurate sequential positioning of the ablation catheter around each veno-atrial junction to deliver point-by-point radiofrequency energy applications in order to achieve complete and persistent electrical disconnection of the PVs. Imaging integration is a new technology that enables guidance during this procedure by showing a three-dimensional, pre-acquired computed tomography or magnetic resonance image and the relative real-time position of the ablation catheter on the screen of the electroanatomic system. Reports in the literature suggest that imaging integration provides accurate visual information with improvement in the procedure parameters and/or clinical outcomes of the procedure.

Entities:  

Keywords:  Atrial fibrillation; Catheter ablation; Electroanatomic mapping; Magnetic resonance imaging; Multislice computed tomography

Year:  2010        PMID: 21160587      PMCID: PMC2998821          DOI: 10.4330/wjc.v2.i8.215

Source DB:  PubMed          Journal:  World J Cardiol


  37 in total

1.  Common pulmonary venous ostium of the right and left inferior pulmonary veins: an unusual pulmonary vein anomaly depicted with 64-slice cardiac computed tomography.

Authors:  Michael Shapiro; Jonathan D Dodd; Thomas J Brady; Suhny Abbara
Journal:  J Cardiovasc Electrophysiol       Date:  2007-01

2.  Factors affecting error in integration of electroanatomic mapping with CT and MR imaging during catheter ablation of atrial fibrillation.

Authors:  E Kevin Heist; Jianping Chevalier; Godtfred Holmvang; Jagmeet P Singh; Patrick T Ellinor; David J Milan; Andre D'Avila; Theofanie Mela; Jeremy N Ruskin; Moussa Mansour
Journal:  J Interv Card Electrophysiol       Date:  2007-01-25       Impact factor: 1.900

Review 3.  HRS/EHRA/ECAS expert Consensus Statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on catheter and surgical ablation of atrial fibrillation.

Authors:  Hugh Calkins; Josep Brugada; Douglas L Packer; Riccardo Cappato; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; David E Haines; Michel Haissaguerre; Yoshito Iesaka; Warren Jackman; Pierre Jais; Hans Kottkamp; Karl Heinz Kuck; Bruce D Lindsay; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Andrea Natale; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Jeremy N Ruskin; Richard J Shemin
Journal:  Heart Rhythm       Date:  2007-04-30       Impact factor: 6.343

4.  Pulmonary vein isolation for the maintenance of sinus rhythm in patients with atrial fibrillation: a meta-analysis of randomized, controlled trials.

Authors:  Jonathan P Piccini; Renato D Lopes; Melissa H Kong; Vic Hasselblad; Kevin Jackson; Sana M Al-Khatib
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-12

5.  Intracardiac echo-guided image integration: optimizing strategies for registration.

Authors:  Tamer S Fahmy; Hanka Mlcochova; Oussama M Wazni; Dimpi Patel; Robert Cihak; Mohamed Kanj; Salwa Beheiry; J David Burkhardt; Thomas Dresing; Steven Hao; Patrick Tchou; Josef Kautzner; Robert A Schweikert; Mauricio Arruda; Walid Saliba; Andrea Natale
Journal:  J Cardiovasc Electrophysiol       Date:  2007-02-02

6.  Image integration using NavX Fusion: initial experience and validation.

Authors:  Anthony G Brooks; Lauren Wilson; Pawel Kuklik; Martin K Stiles; Bobby John; Hany Dimitri; Dennis H Lau; Ross L Roberts-Thomson; Christopher X Wong; Glenn D Young; Prashanthan Sanders
Journal:  Heart Rhythm       Date:  2008-01-17       Impact factor: 6.343

Review 7.  Catheter ablation vs antiarrhythmic drug therapy for atrial fibrillation: a systematic review.

Authors:  Amit Noheria; Abhishek Kumar; John V Wylie; Mark E Josephson
Journal:  Arch Intern Med       Date:  2008-03-24

8.  Novel ICE-guided registration strategy for integration of electroanatomical mapping with three-dimensional CT/MR images to guide catheter ablation of atrial fibrillation.

Authors:  Antonio Rossillo; Stefano Indiani; Aldo Bonso; Sakis Themistoclakis; Andrea Corrado; Antonio Raviele
Journal:  J Cardiovasc Electrophysiol       Date:  2008-10-27

9.  Image-integration of intraprocedural rotational angiography-based 3D reconstructions of left atrium and pulmonary veins into electroanatomical mapping: accuracy of a novel modality in atrial fibrillation ablation.

Authors:  Georg Nölker; Stefan Asbach; Klaus J Gutleben; Harald Rittger; Guido Ritscher; Johannes Brachmann; Anil M Sinha
Journal:  J Cardiovasc Electrophysiol       Date:  2009-10-05

10.  Image integration increases efficacy of paroxysmal atrial fibrillation catheter ablation: results from the CartoMerge Italian Registry.

Authors:  Emanuele Bertaglia; Paolo Della Bella; Claudio Tondo; Alessandro Proclemer; Nicola Bottoni; Roberto De Ponti; Maurizio Landolina; Maria Grazia Bongiorni; Leonardo Corò; Giuseppe Stabile; Antonio Dello Russo; Roberto Verlato; Massimo Mantica; Franco Zoppo
Journal:  Europace       Date:  2009-06-18       Impact factor: 5.214

View more
  4 in total

Review 1.  Role of Cardiac Imaging (CT/MR) Before and After RF Catheter Ablation in Patients with Atrial Fibrillation.

Authors:  Aravindan Kolandaivelu
Journal:  J Atr Fibrillation       Date:  2012-08-20

2.  Role of catheter ablation of ventricular tachycardia associated with structural heart disease.

Authors:  Roberto De Ponti
Journal:  World J Cardiol       Date:  2011-11-26

3.  Reduction of radiation exposure in catheter ablation of atrial fibrillation: Lesson learned.

Authors:  Roberto De Ponti
Journal:  World J Cardiol       Date:  2015-08-26

Review 4.  Catheter Ablation of Atrial Fibrillation Without Radiation Exposure Using A 3D Mapping System.

Authors:  Marco Scaglione; Elisa Ebrille; Francesca Di Clemente; Fiorenzo Gaita; Jason S Bradfield
Journal:  J Atr Fibrillation       Date:  2015-02-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.