Novel ICE-guided registration strategy for integration of electroanatomical mapping with three-dimensional CT/MR images to guide catheter ablation of atrial fibrillation.

Antonio Rossillo1, Stefano Indiani, Aldo Bonso, Sakis Themistoclakis, Andrea Corrado, Antonio Raviele.   

Abstract

INTRODUCTION: Image integration is used in AF ablation procedures. To maximize the efficacy of image integration, it is essential to obtain good alignment between the electroanatomical map and the 3D image of the heart. In the present study, we compared an ICE-guided landmark registration with an ICE-guided focused endocardial surface registration. METHODS AND
RESULTS: In 20 patients, registration was based on posterior landmarks acquired under ICE guidance (group A); in another 20 matched patients, a new ICE-guided focused endocardial surface registration technique was used (group B). In these latter patients, a single landmark was acquired in the inferior part of the LIPV, and several surface points were recorded in the posterior area of the left PV antrum and around the antra of the right PVs. The mean ablation point-to-CT image distance was calculated in both groups. In group A, the mean landmark point-to-CT image distance was also calculated after adding the surface registration. The mean landmark point-to-CT image distance was 4.62 +/- 1.65 mm and increased to 7.66 +/- 2.44 mm when surface registration was added. The ablation point-to-CT image distance was significantly shorter in group B (1.73 +/- 0.29 mm vs 3 +/- 0.99 mm; P < 0.001).
CONCLUSIONS: This ICE-guided focused endocardial surface registration seems to be superior to landmark registration in achieving a better alignment between the CT/MR image and the electroanatomical map. The concurrent use of standard surface registration may result in rotation of the atrial chamber.

Entities:  

Mesh:

Year:  2008        PMID: 19017352     DOI: 10.1111/j.1540-8167.2008.01332.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  6 in total

Review 1.  Intracardiac echocardiography in complex cardiac catheter ablation procedures.

Authors:  Javier E Banchs; Parag Patel; Gerald V Naccarelli; Mario D Gonzalez
Journal:  J Interv Card Electrophysiol       Date:  2010-05-18       Impact factor: 1.900

2.  Improving the cardiac cath-lab interventional imaging eco-system.

Authors:  Benjamin R Ciske; Michael A Speidel; Amish N Raval
Journal:  Transl Pediatr       Date:  2018-01

Review 3.  Role of Intracardiac echocardiography in Atrial Fibrillation Ablation.

Authors:  Antonio Dello Russo; Eleonora Russo; Gaetano Fassini; Michela Casella; Ester Innocenti; Martina Zucchetti; Claudia Cefalu; Francesco Solimene; Gaetano Mottola; Daniele Colombo; Fabrizio Bologna; Benedetta Majocchi; Pasquale Santangeli; Stefania Riva; Luigi Di Biase; Cesare Fiorentini; Claudio Tondo
Journal:  J Atr Fibrillation       Date:  2013-04-06

4.  A piecewise patch-to-model matching method for image-guided cardiac catheter ablation.

Authors:  Jiquan Liu; Maryam E Rettmann; David R Holmes; Huilong Duan; Richard A Robb
Journal:  Comput Med Imaging Graph       Date:  2011-03-03       Impact factor: 4.790

5.  Role of three-dimensional imaging integration in atrial fibrillation ablation.

Authors:  Roberto De Ponti; Raffaella Marazzi; Domenico Lumia; Giuseppe Picciolo; Roberto Biddau; Carlo Fugazzola; Jorge A Salerno-Uriarte
Journal:  World J Cardiol       Date:  2010-08-26

6.  Safety and feasibility of atrial fibrillation ablation using Amigo® system versus manual approach: A pilot study.

Authors:  Antonio Scarà; Luigi Sciarra; Ermenegildo De Ruvo; Alessio Borrelli; Domenico Grieco; Zefferino Palamà; Paolo Golia; Lucia De Luca; Marco Rebecchi; Leonardo Calò
Journal:  Indian Pacing Electrophysiol J       Date:  2017-11-01
  6 in total