Literature DB >> 21158292

Flow measurement in MRI using arterial spin labeling with cumulative readout pulses--theory and validation.

Yi Wang1, Seong-Eun Kim, Edward V R DiBella, Dennis L Parker.   

Abstract

PURPOSE: This article systematically examines arterial spin labeling (ASL) as a flow quantification technique through theoretical simulation, in vitro, and in vivo experiment. The authors present a novel imaging pulse sequence design consisting of a single ASL magnetization preparation followed by Look-Locker-like image readouts. Bloch-equation-based modeling has been developed and validated using a hemodialyzer as a tissue-mimicking flow phantom.
METHODS: After the single in-plane slice-selective double inversion magnetization preparation, multiple TFL readouts are acquired with linear k-space ordering, causing a signal variation that depends on through-slice flow velocity. Computer simulations were performed to assess the behavior of the flow-dependent ASL signal as a function of varying imaging parameters. The signal was optimized by choosing imaging parameters that maximize the simulated flow-sensitive signal. Furthermore, a hemodialyzer which mimics blood flow in human tissues was tested with a wide range of flow rates. An exponential curve fitting of the flow-sensitive dynamics to the model derived from Bloch equations provides a method to estimate through-slice velocity for varying flow rates on the hemodialyzer and in vivo human brain.
RESULTS: The flow dependency of the ASL signal and the sensitivity of the ASL signal to imaging parameters were demonstrated. Experimental results from a hemodialyzer when fitted with a Bloch-equation-based model provide flow measurements that are consistent with ground truth velocities. Human brain velocity mapping was obtained as well.
CONCLUSIONS: The results provide evidence that the proposed pulse sequence design is an effective technique to measure total fluid flow through image voxels. The unique combination of the two main features, multiple-image readout after a single ASL preparation and linear acquisition ordering in the phase encoding direction in TFL imaging, make this technique an appealing flow imaging method to quantify through-plane flow in a time-efficient manner.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21158292      PMCID: PMC2973993          DOI: 10.1118/1.3501881

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  26 in total

1.  Arterial spin labeling in combination with a look-locker sampling strategy: inflow turbo-sampling EPI-FAIR (ITS-FAIR).

Authors:  M Günther; M Bock; L R Schad
Journal:  Magn Reson Med       Date:  2001-11       Impact factor: 4.668

2.  TurboFLASH FAIR imaging with optimized inversion and imaging profiles.

Authors:  Gaby S Pell; David P Lewis; Roger J Ordidge; Craig A Branch
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  Breast tissue differentiation using arterial spin tagging.

Authors:  David C Zhu; Michael H Buonocore
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

4.  Flow quantification in the superior sagittal sinus using magnetic resonance.

Authors:  H Mattle; R R Edelman; M A Reis; D J Atkinson
Journal:  Neurology       Date:  1990-05       Impact factor: 9.910

5.  Magnetic resonance imaging of perfusion using spin inversion of arterial water.

Authors:  D S Williams; J A Detre; J S Leigh; A P Koretsky
Journal:  Proc Natl Acad Sci U S A       Date:  1992-01-01       Impact factor: 11.205

6.  Comparison of pulsed arterial spin labeling encoding schemes and absolute perfusion quantification.

Authors:  Mustafa Cavuşoğlu; Josef Pfeuffer; Kâmil Uğurbil; Kâmil Uludağ
Journal:  Magn Reson Imaging       Date:  2009-06-21       Impact factor: 2.546

7.  Detection of regional pulmonary perfusion deficit of the occluded lung using arterial spin labeling in magnetic resonance imaging.

Authors:  V M Mai; K D Hagspiel; T Altes; A R Goode; M B Williams; S S Berr
Journal:  J Magn Reson Imaging       Date:  2000-02       Impact factor: 4.813

8.  Tumor vessel destruction resulting from high-intensity focused ultrasound in patients with solid malignancies.

Authors:  Feng Wu; Wen-Zhi Chen; Jin Bai; Jian-Zhong Zou; Zhi-Long Wang; Hui Zhu; Zhi-Biao Wang
Journal:  Ultrasound Med Biol       Date:  2002-04       Impact factor: 2.998

9.  Blood flow in normal tissues and tumors during hyperthermia.

Authors:  C W Song; J G Rhee; S H Levitt
Journal:  J Natl Cancer Inst       Date:  1980-01       Impact factor: 13.506

10.  Perfusion imaging.

Authors:  J A Detre; J S Leigh; D S Williams; A P Koretsky
Journal:  Magn Reson Med       Date:  1992-01       Impact factor: 4.668

View more
  3 in total

1.  Simultaneous multi-slice Turbo-FLASH imaging with CAIPIRINHA for whole brain distortion-free pseudo-continuous arterial spin labeling at 3 and 7 T.

Authors:  Yi Wang; Steen Moeller; Xiufeng Li; An T Vu; Kate Krasileva; Kamil Ugurbil; Essa Yacoub; Danny J J Wang
Journal:  Neuroimage       Date:  2015-03-30       Impact factor: 6.556

2.  Semipermeable Hollow Fiber Phantoms for Development and Validation of Perfusion-Sensitive MR Methods and Signal Models.

Authors:  J R Anderson; J J H Ackerman; J R Garbow
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2011-08       Impact factor: 1.176

3.  Quantitative imaging: systematic review of perfusion/flow phantoms.

Authors:  Marije E Kamphuis; Marcel J W Greuter; Riemer H J A Slart; Cornelis H Slump
Journal:  Eur Radiol Exp       Date:  2020-03-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.