| Literature DB >> 21157068 |
Tarannum Mansoori1, Kalluri Viswanath, Nagalla Balakrishna.
Abstract
PURPOSE: The aim was to study optic nerve head (ONH) parameters in normal Indian eyes using spectral domain optical coherence tomography (OCT)/scanning laser ophthamoscope (SLO).Entities:
Mesh:
Year: 2011 PMID: 21157068 PMCID: PMC3032238 DOI: 10.4103/0301-4738.73716
Source DB: PubMed Journal: Indian J Ophthalmol ISSN: 0301-4738 Impact factor: 1.848
Mean ± standard deviation (SD), range, 95% confidence interval for mean, first, fifth, fiftieth and ninety fifth percentiles of various optic nerve head (ONH) parameters
| ONH parameters | Mean ± SD | Range | 95% confidence interval for mean | 1st percentile | 5th percentile | 50th percentile | 95th percentile |
|---|---|---|---|---|---|---|---|
| Disc area (mm2) | 3.36 ± 0.64 | 2.13 – 5.08 | 3.27 – 3.69 | 2.14 | 2.42 | 3.37 | 4.85 |
| Cup area (mm2) | 1.1 ± 0.75 | 0.0 – 3.07 | 0.98 – 1.22 | 0.0 | 0.0 | 1.63 | 3.82 |
| Rim area (mm2) | 2.49 ± 0.58 | 1.20 – 3.62 | 2.4 – 2.58 | 0.58 | 0.82 | 1.65 | 2.74 |
| Cup/disc horizontal ratio | 0.5 ± 0.23 | 0.0 – 0.88 | 0.46 – 0.53 | 0.0 | 0.0 | 0.81 | 0.9 |
| Cup/disc vertical ratio | 0.5 ± 0.21 | 0.0 – 0.81 | 0.47 – 0.54 | 0.0 | 0.0 | 0.71 | 0.88 |
| Cup/disc area ratio | 0.29 ± 0.18 | 0.0 – 0.68 | 0.26 – 0.32 | 0.0 | 0.0 | 0.51 | 0.81 |
| Mean cup depth (mm) | 0.18 ± 0.11 | 0.0 – 0.53 | 0.16 – 0.19 | 0.0 | 0.0 | 0.14 | 0.3 |
| Maximum cup depth (mm) | 0.36 ± 0.21 | 0.0 – 0.98 | 0.33 – 0.4 | 0.0 | 0.0 | 0.37 | 0.64 |
Gender based comparison (Mean ± standard deviation) of Optic nerve head topography parameters in study population
| Optic disc parameters | Male | Female | |
|---|---|---|---|
| Disc area (mm2) | 3.31 ± 0.7 | 3.29 ± 0.6 | 0.5 |
| Cup area (mm2) | 1.2 ± 0.7 | 1.2 ± 0.7 | 0.1 |
| Rim area (mm2) | 2.5 ± 0.5 | 2.5 ± 0.6 | 0.1 |
| Cup/disc horizontal ratio | 0.53 ± 0.2 | 0.5 ± 0.2 | 0.3 |
| Cup/Disc vertical ratio | 0.5 ± 0.2 | 0.47 ± 0.2 | 0.1 |
| Cup/Disc area ratio | 0.32 ± 0.2 | 0.27 ± 0.2 | 0.1 |
| Mean cup depth (mm) | 0.19 ± 0.1 | 0.17 ± 0.1 | 0.3 |
| Maximum cup depth (mm) | 0.39 ± 0.2 | 0.34 ± 0.2 | 0.15 |
Effect of optic disc area (Y) on optic disc variables (X)
| Variables | Equation | Correlation coefficient (R) | |
|---|---|---|---|
| Cup area (mm2) | Y= 2.97 + 0.57 X | <0.001 | 0.63 |
| Rim area (mm2) | Y= 2.94 + 0.26 X | <0.001 | 0.25 |
| Cup / disc horizontal ratio | Y= 2.89 + 1.41 X | <0.001 | 0.45 |
| Cup / disc vertical ratio | Y= 2.71 + 1.72 X | <0.001 | 0.48 |
| Cup / disc area ratio | Y= 3.09 + 1.70 X | <0.001 | 0.45 |
| Mean cup depth (mm) | Y= 3.21 + 2.15 X | <0.001 | 0.38 |
| Maximum cup depth (mm) | Y= 3.20 + 1.09 X | <0.001 | 0.37 |
Disc area in normal eyes as reported in various studies
| Authors | Population studied | Method of disc examination | Number of subjects | Mean disc area in mm2 (standard deviation) |
|---|---|---|---|---|
| Present study | Indian | Spectral domain OCT | 157 | 3.36 (0.64) |
| Sekhar | Indian | Planimetry | 143 | 3.37 (0.68) |
| Jonas | Indian | Stereophotographs | 70 | 2.58 (0.65) |
| Dacosta | Indian | Stratus OCT | 150 | 2.63 (0.55) |
| Agarwal | Indian | HRT II | 275 | 2.34(0.47) |
| Varma | Blacks | Stereophotographs with image analyzer | 2903 | 2.94(0.74) |
| Whites | 3475 | 2.63(0.46) | ||
| Funaki | Japanese | Scanning laser polarimetry | 60 | 2.2(0.55) |
| R Ramakrishnan | Indian | OCT 3 | 82 | 2.37 (0.51) |
| Planimetry | 82 | 2.83 (0.62) | ||
| Medeiros | Caucasian | Stratus OCT | 78 | 2.35 (0.51) |
| Marsh | Whites | Stratus OCT | 212 | 2.17 (95% CI 1.56-2.99) |
| Hispanic | 2.33 (95% CI 1.67-3.09) | |||
| African - American | 2.49 (95% CI 1.8-3.24) |