Literature DB >> 12701859

The normal optic nerve head on Heidelberg Retina Tomograph II.

Harish C Agarwal1, Vikas Gulati, Ramanjit Sihota.   

Abstract

PURPOSE: To study the characteristics of the optic nerve head using a scanning laser ophthalmoscope, the Heidelberg Retina Tomograph II (HRT II), in a normal population and to determine the specificity of HRT II diagnostic indices in the study population.
METHODS: The optic nerve heads from 275 consecutive, randomly selected normal subjects were imaged on HRT II. Stereometric parameters were studied with respect to baseline variables such as age, gender, refractive error and disc size. The stereometric parameters and the results of Moorfields regression analysis (MRA) and discriminant function analysis were recorded.
RESULTS: The average disc size in the population under study was 2.34 +/- 0.47 mm2. Age and gender had no significant effect on stereometric parameters. Myopic discs were larger than hypermetropic discs. MRA had a specificity varying between 85.5% and 98.2% depending upon the criteria used to define an abnormal disc. The specificity of MRA decreased with increasing disc size. The RB (R Bathija) and FSM (F S Mikelberg) discriminant functions had specificities of 96.4% and 87.3% respectively.
CONCLUSIONS: Estimation of stereometric parameters of a normal disc can be used to indicate an abnormal one. Moorfields regression analysis and discriminant functions have a high specificity in our normal population; however caution must be exercised in interpreting the results for a disc area larger than 3 mm2.

Mesh:

Year:  2003        PMID: 12701859

Source DB:  PubMed          Journal:  Indian J Ophthalmol        ISSN: 0301-4738            Impact factor:   1.848


  5 in total

1.  Laser scanning tomography in the EPIC-Norfolk Eye Study: principal components and associations.

Authors:  Anthony P Khawaja; Michelle P Y Chan; David C Broadway; David F Garway-Heath; Robert Luben; Jennifer L Y Yip; Shabina Hayat; Kay-Tee Khaw; Paul J Foster
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-10-09       Impact factor: 4.799

Review 2.  Optic disk size and glaucoma.

Authors:  Esther M Hoffmann; Linda M Zangwill; Jonathan G Crowston; Robert N Weinreb
Journal:  Surv Ophthalmol       Date:  2007 Jan-Feb       Impact factor: 6.197

3.  Optic disc topography in normal Indian eyes using spectral domain optical coherence tomography.

Authors:  Tarannum Mansoori; Kalluri Viswanath; Nagalla Balakrishna
Journal:  Indian J Ophthalmol       Date:  2011 Jan-Feb       Impact factor: 1.848

4.  Comparison of the diagnostic ability of Moorfield's regression analysis and glaucoma probability score using Heidelberg retinal tomograph III in eyes with primary open angle glaucoma.

Authors:  Shveta Jindal; Tanuj Dada; V Sreenivas; Viney Gupta; Ramanjit Sihota; Anita Panda
Journal:  Indian J Ophthalmol       Date:  2010 Nov-Dec       Impact factor: 1.848

5.  Determinants of maximum cup depth in non-glaucoma and primary open-angle glaucoma subjects: a population-based study.

Authors:  Qing Zhang; Ye Zhang; Chen Xin; Yingyan Mao; Kai Cao; Catherine Jan; Chunyu Guo; Ningli Wang; Ravi Thomas
Journal:  Eye (Lond)       Date:  2019-09-27       Impact factor: 3.775

  5 in total