Literature DB >> 21156978

First clinical evaluation of the C-MAC D-Blade videolaryngoscope during routine and difficult intubation.

Erol Cavus1, Tobias Neumann, Volker Doerges, Thora Moeller, Edwin Scharf, Klaus Wagner, Berthold Bein, Goetz Serocki.   

Abstract

In the present preliminary study we evaluated the C-MAC® D-Blade (Karl Storz, Tuttlingen, Germany), a new videolaryngoscopic C-MAC blade for difficult intubation, during both routine and difficult intubations. First, both the conventional direct laryngoscopy and the D-Blade were used in 15 consecutive patients with normal airways during routine induction of anesthesia. Second, the D-Blade was used as a rescue device in 20 of 300 (6.7%) consecutive patients, when conventional direct laryngoscopy failed. In the 15 patients during routine induction of anesthesia, with direct laryngoscopy, a Cormack-Lehane (C/L) grade 1 and grade 2a view was seen in 7 and 8 patients, respectively. It was possible to insert the D-Blade and to get a video view of the glottis on the first attempt in all patients; with the D-Blade, all 15 patients had a C/L 1 view. The time to successful intubation with the D-Blade was 15 (8-26) seconds (median (range)). In the 20 patients, in whom unexpected difficulty with direct laryngoscopy was observed, C/L grades 3 and 4 were present in 15 and 5 patients, respectively. With the use of the D-Blade, indirect C/L video view improved to C/L class 1 in 15 patients, and to 2a in 5 patients, respectively. The time from touching the laryngoscope to optimal laryngoscopic view was 11 (5-45) seconds and for successful intubation 17 (3-80) seconds. In all 35 patients, with the D-Blade no direct view of the glottis was possible and subsequently a semiflexible tube guide was required.

Entities:  

Mesh:

Year:  2010        PMID: 21156978     DOI: 10.1213/ANE.0b013e31820553fb

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  31 in total

Review 1.  [S1 guidelines on airway management].

Authors:  T Piepho; E Cavus; R Noppens; C Byhahn; V Dörges; B Zwissler; A Timmermann
Journal:  Anaesthesist       Date:  2015-11       Impact factor: 1.041

2.  S1 guidelines on airway management : Guideline of the German Society of Anesthesiology and Intensive Care Medicine.

Authors:  T Piepho; E Cavus; R Noppens; C Byhahn; V Dörges; B Zwissler; A Timmermann
Journal:  Anaesthesist       Date:  2015-12       Impact factor: 1.041

3.  Comparison of cervical spine motion during intubation with a C‑MAC D‑Blade® and an LMA Fastrach®.

Authors:  D Özkan; S Altınsoy; M Sayın; H Dolgun; J Ergil; A Dönmez
Journal:  Anaesthesist       Date:  2019-01-09       Impact factor: 1.041

4.  [Rapid sequence induction and intubation in patients with risk of aspiration : Recommendations for action for practical management of anesthesia].

Authors:  C Eichelsbacher; H Ilper; R Noppens; J Hinkelbein; T Loop
Journal:  Anaesthesist       Date:  2018-06-29       Impact factor: 1.041

5.  Comparison of Macintosh, McCoy and C-MAC D-Blade video laryngoscope intubation by prehospital emergency health workers: a simulation study.

Authors:  Ahmet Yildirim; Hasan A Kiraz; İbrahim Ağaoğlu; Okhan Akdur
Journal:  Intern Emerg Med       Date:  2016-03-21       Impact factor: 3.397

6.  Comparison of the C-MAC D-Blade, Conventional C-MAC, and Macintosh Laryngoscopes in Simulated Easy and Difficult Airways.

Authors:  Alper Kılıçaslan; Ahmet Topal; Atilla Erol; Sema Tuncer Uzun
Journal:  Turk J Anaesthesiol Reanim       Date:  2014-08-01

7.  [Reintubation using the C-MAC videolaryngoscope. Implementation in patients with difficult airways initially managed with in situ laryngeal tubes].

Authors:  R Schalk; C F Weber; C Byhahn; C Reyher; D Stay; K Zacharowski; D Meininger
Journal:  Anaesthesist       Date:  2012-08-29       Impact factor: 1.041

8.  Inexpensive video-laryngoscopy guided intubation using a personal computer: initial experience of a novel technique.

Authors:  John George Karippacheril; Goneppanavar Umesh; Venkateswaran Ramkumar
Journal:  J Clin Monit Comput       Date:  2013-10-17       Impact factor: 2.502

9.  Predictors of difficult videolaryngoscopy with GlideScope® or C-MAC® with D-blade: secondary analysis from a large comparative videolaryngoscopy trial.

Authors:  M F Aziz; E O Bayman; M M Van Tienderen; M M Todd; A M Brambrink
Journal:  Br J Anaesth       Date:  2016-07       Impact factor: 9.166

10.  Paediatric airway management: What is new?

Authors:  S Ramesh; R Jayanthi; S R Archana
Journal:  Indian J Anaesth       Date:  2012-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.