Literature DB >> 21150671

ProDisc-C: an in vivo kinematic study.

Neil Duggal1, Rudolf Bertagnoli, Doron Rabin, Nicholas Wharton, Izabela Kowalczyk.   

Abstract

STUDY
DESIGN: A prospective study of 22 patients with single-level cervical spondylosis.
OBJECTIVE: To quantify the changes in the biomechanics of the cervical spine after the insertion of a ProDisc-C (Synthes Spine, Paoli, PA) artificial disc. SUMMARY OF BACKGROUND DATA: Cervical arthroplasty is designed to maintain cervical motion of the functional spinal unit (FSU) after cervical discectomy. The impact of the ProDisc-C on in vivo kinematics and sagittal alignment requires further assessment.
METHODS: Flexion/extension lateral radiographs of the cervical spine were prospectively collected and reviewed in 22 patients preoperatively and after the placement of ProDisc-C. Disc height (DH), FSU angle, range of motion (ROM), and center of rotation (COR) were calculated at each time point using validated, computer-assisted methods. Preoperative values were compared with the postoperative values using paired student t tests.
RESULTS: Mean follow-up time was 11.0 months (SD, 2.4 mo). At the surgical level, the ProDisc-C produced increased segmental ROM (P = 0.03), an anterior shift of 1.1 mm in COR X (P = 0.004), and increased DH both anteriorly (P < 0.0001) and posteriorly (P < 0.0001). At the inferior adjacent level, anterior DH decreased (P < 0.05) and posterior DH increased (P = 0.02) after surgery. The FSU angle at the surgical level increased (P < 0.0001), but the inferior adjacent-level FSU angle decreased (P = 0.002). No significant changes were observed at the superior adjacent level.
CONCLUSIONS: The ProDisc-C increased segmental ROM and shifted the COR anteriorly at the surgical level. DH increased at the surgical level. The surgical level became more lordotic, whereas the inferior adjacent level became more kyphotic after ProDisc-C implantation.

Entities:  

Mesh:

Year:  2011        PMID: 21150671     DOI: 10.1097/BSD.0b013e3181fbf8aa

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  4 in total

1.  Biomechanical effects of cervical arthroplasty with U-shaped disc implant on segmental range of motion and loading of surrounding soft tissue.

Authors:  Zhong Jun Mo; Yan Bin Zhao; Li Zhen Wang; Yu Sun; Ming Zhang; Yu Bo Fan
Journal:  Eur Spine J       Date:  2013-10-24       Impact factor: 3.134

Review 2.  Spinal facet joint biomechanics and mechanotransduction in normal, injury and degenerative conditions.

Authors:  Nicolas V Jaumard; William C Welch; Beth A Winkelstein
Journal:  J Biomech Eng       Date:  2011-07       Impact factor: 2.097

3.  [Effectiveness evaluation of Prodisc-C prosthesis for more than 10 years follow-up after total cervical disc replacement].

Authors:  Shuai Xu; Yan Liang; Zhenqi Zhu; Kaifeng Wang; Haiying Liu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-04-15

4.  Mid-long-term follow-up of operated level kinematics after single-level artificial cervical disc replacement with Bryan disc.

Authors:  Chuanhong Li; Xing Yu; Yang Xiong; Yongdong Yang; Fengxian Wang; He Zhao
Journal:  J Orthop Surg Res       Date:  2022-03-09       Impact factor: 2.359

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.