Literature DB >> 21149947

A cubic B-spline-based hybrid registration of lung CT images for a dynamic airway geometric model with large deformation.

Youbing Yin1, Eric A Hoffman, Kai Ding, Joseph M Reinhardt, Ching-Long Lin.   

Abstract

The goal of this study is to develop a matching algorithm that can handle large geometric changes in x-ray computed tomography (CT)-derived lung geometry occurring during deep breath maneuvers. These geometric relationships are further utilized to build a dynamic lung airway model for computational fluid dynamics (CFD) studies of pulmonary air flow. The proposed algorithm is based on a cubic B-spline-based hybrid registration framework that incorporates anatomic landmark information with intensity patterns. A sequence of invertible B-splines is composed in a multiresolution framework to ensure local invertibility of the large deformation transformation and a physiologically meaningful similarity measure is adopted to compensate for changes in voxel intensity due to inflation. Registrations are performed using the proposed approach to match six pairs of 3D CT human lung datasets. Results show that the proposed approach has the ability to match the intensity pattern and the anatomical landmarks, and ensure local invertibility for large deformation transformations. Statistical results also show that the proposed hybrid approach yields significantly improved results as compared with approaches using either landmarks or intensity alone.

Entities:  

Mesh:

Year:  2010        PMID: 21149947      PMCID: PMC3115562          DOI: 10.1088/0031-9155/56/1/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  40 in total

1.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

2.  Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry.

Authors:  Gary E Christensen; Joo Hyun Song; Wei Lu; Issam El Naqa; Daniel A Low
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

3.  A fast nonrigid image registration with constraints on the Jacobian using large scale constrained optimization.

Authors:  Michaël Sdika
Journal:  IEEE Trans Med Imaging       Date:  2008-02       Impact factor: 10.048

4.  Fast parametric elastic image registration.

Authors:  Jan Kybic; Michael Unser
Journal:  IEEE Trans Image Process       Date:  2003       Impact factor: 10.856

5.  A rigidity penalty term for nonrigid registration.

Authors:  Marius Staring; Stefan Klein; Josien P W Pluim
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

6.  Pulmonary CT image registration and warping for tracking tissue deformation during the respiratory cycle through 3D consistent image registration.

Authors:  Baojun Li; Gary E Christensen; Eric A Hoffman; Geoffrey McLennan; Joseph M Reinhardt
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

7.  Registration-based estimates of local lung tissue expansion compared to xenon CT measures of specific ventilation.

Authors:  Joseph M Reinhardt; Kai Ding; Kunlin Cao; Gary E Christensen; Eric A Hoffman; Shalmali V Bodas
Journal:  Med Image Anal       Date:  2008-04-12       Impact factor: 8.545

8.  Evaluation of lobar biomechanics during respiration using image registration.

Authors:  Kai Ding; Youbing Yin; Kunlin Cao; Gary E Christensen; Ching-Long Lin; Eric A Hoffman; Joseph M Reinhardt
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

9.  A simple regularizer for B-spline nonrigid image registration that encourages local invertibility.

Authors:  Se Young Chun; Jeffrey A Fessler
Journal:  IEEE J Sel Top Signal Process       Date:  2009-02-01       Impact factor: 6.856

10.  The effects of geometry on airflow in the acinar region of the human lung.

Authors:  Haribalan Kumar; Merryn H Tawhai; Eric A Hoffman; Ching-Long Lin
Journal:  J Biomech       Date:  2009-05-31       Impact factor: 2.712

View more
  20 in total

1.  A 4DCT imaging-based breathing lung model with relative hysteresis.

Authors:  Shinjiro Miyawaki; Sanghun Choi; Eric A Hoffman; Ching-Long Lin
Journal:  J Comput Phys       Date:  2016-08-31       Impact factor: 3.553

Review 2.  Deformable medical image registration: a survey.

Authors:  Aristeidis Sotiras; Christos Davatzikos; Nikos Paragios
Journal:  IEEE Trans Med Imaging       Date:  2013-05-31       Impact factor: 10.048

3.  A fast deformable registration method for 4D lung CT in hybrid framework.

Authors:  Wei Xia; Xin Gao
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-11-22       Impact factor: 2.924

4.  Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

Authors:  Min Li; Sarah Joy Castillo; Richard Castillo; Edward Castillo; Thomas Guerrero; Liang Xiao; Xiaolin Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-14       Impact factor: 2.924

5.  Deformable registration of the inflated and deflated lung in cone-beam CT-guided thoracic surgery: initial investigation of a combined model- and image-driven approach.

Authors:  Ali Uneri; Sajendra Nithiananthan; Sebastian Schafer; Yoshito Otake; J Webster Stayman; Gerhard Kleinszig; Marc S Sussman; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

6.  Multiscale imaging and registration-driven model for pulmonary acinar mechanics in the mouse.

Authors:  Haribalan Kumar; Dragos M Vasilescu; Youbing Yin; Eric A Hoffman; Merryn H Tawhai; Ching-Long Lin
Journal:  J Appl Physiol (1985)       Date:  2013-02-14

7.  Analysis of three-dimensional aerosol deposition in pharmacologically relevant terms: beyond black or white ROIs.

Authors:  Elliot Eliyahu Greenblatt; Tilo Winkler; Robert Scott Harris; Vanessa Jane Kelly; Mamary Kone; Jose Venegas
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2014-07-22       Impact factor: 2.849

8.  A multiscale MDCT image-based breathing lung model with time-varying regional ventilation.

Authors:  Youbing Yin; Jiwoong Choi; Eric A Hoffman; Merryn H Tawhai; Ching-Long Lin
Journal:  J Comput Phys       Date:  2013-07-01       Impact factor: 3.553

9.  A PERFECT MATCH CONDITION FOR POINT-SET MATCHING PROBLEMS USING THE OPTIMAL MASS TRANSPORT APPROACH.

Authors:  Pengwen Chen; Ching-Long Lin; I-Liang Chern
Journal:  SIAM J Imaging Sci       Date:  2013-04-03       Impact factor: 2.867

10.  Efficient methods for implementation of multi-level nonrigid mass-preserving image registration on GPUs and multi-threaded CPUs.

Authors:  Nathan D Ellingwood; Youbing Yin; Matthew Smith; Ching-Long Lin
Journal:  Comput Methods Programs Biomed       Date:  2016-01-06       Impact factor: 5.428

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.