Literature DB >> 21148342

Left ventricular epicardial admittance measurement for detection of acute LV dilation.

John E Porterfield1, Erik R Larson, James T Jenkins, Daniel Escobedo, Jonathan W Valvano, John A Pearce, Marc D Feldman.   

Abstract

There are two implanted heart failure warning systems incorporated into biventricular pacemakers/automatic implantable cardiac defibrillators and tested in clinical trials: right heart pressures, and lung conductance measurements. However, both warning systems postdate measures of the earliest indicator of impending heart failure: left ventricular (LV) volume. There are currently no proposed implanted technologies that can perform LV blood volume measurements in humans. We propose to solve this problem by incorporating an admittance measurement system onto currently deployed biventricular and automatic implantable cardiac defibrillator leads. This study will demonstrate that an admittance measurement system can detect LV blood conductance from the epicardial position, despite the current generating and sensing electrodes being in constant motion with the heart, and with dynamic removal of the myocardial component of the returning voltage signal. Specifically, in 11 pigs, it will be demonstrated that 1) a physiological LV blood conductance signal can be derived; 2) LV dilation in response to dose-response intravenous neosynephrine can be detected by blood conductance in a similar fashion to the standard of endocardial crystals when admittance is used, but not when only traditional conductance is used; 3) the physiological impact of acute left anterior descending coronary artery occlusion and resultant LV dilation can be detected by blood conductance, before the anticipated secondary rise in right ventricular systolic pressure; and 4) a pleural effusion simulated by placing saline outside the pericardium does not serve as a source of artifact for blood conductance measurements.

Entities:  

Mesh:

Year:  2010        PMID: 21148342      PMCID: PMC3069629          DOI: 10.1152/japplphysiol.01047.2010

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  33 in total

1.  Nonlinear conductance-volume relationship for murine conductance catheter measurement system.

Authors:  Chia-Ling Wei; Jonathan W Valvano; Marc D Feldman; John A Pearce
Journal:  IEEE Trans Biomed Eng       Date:  2005-10       Impact factor: 4.538

2.  Design of a wireless telemetric backpack device for real-time in vivo measurement of pressure-volume loops in conscious ambulatory rats.

Authors:  Karthik Raghavan; Anil T G Kottam; Jonathan W Valvano; John A Pearce
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

3.  Clinical trials update from the European Society of Cardiology Heart Failure meeting and the American College of Cardiology: darbepoetin alfa study, ECHOS, and ASCOT-BPLA.

Authors:  John G F Cleland; Alison P Coletta; Andrew L Clark; Periaswamy Velavan; Lee Ingle
Journal:  Eur J Heart Fail       Date:  2005-08       Impact factor: 15.534

4.  Impact of physiological variables and genetic background on myocardial frequency-resistivity relations in the intact beating murine heart.

Authors:  Maricela Reyes; Mark E Steinhelper; Jorge A Alvarez; Daniel Escobedo; John Pearce; Jonathan W Valvano; Brad H Pollock; Chia-Ling Wei; Anil Kottam; David Altman; Steven Bailey; Sharon Thomsen; Shuko Lee; James T Colston; Jung Hwan Oh; Gregory L Freeman; Marc D Feldman
Journal:  Am J Physiol Heart Circ Physiol       Date:  2006-05-12       Impact factor: 4.733

5.  Clinical utility of intrathoracic impedance monitoring to alert patients with an implanted device of deteriorating chronic heart failure.

Authors:  Dirk Vollmann; Herbert Nägele; Patrick Schauerte; Uwe Wiegand; Christian Butter; Gabriele Zanotto; Aurelio Quesada; Axel Guthmann; Michael R S Hill; Barbara Lamp
Journal:  Eur Heart J       Date:  2007-02-19       Impact factor: 29.983

6.  Wireless acoustic communication with a miniature pressure sensor in the pulmonary artery for disease surveillance and therapy of patients with congestive heart failure.

Authors:  Yoseph Rozenman; Robert S Schwartz; Hetal Shah; Keyur H Parikh
Journal:  J Am Coll Cardiol       Date:  2007-02-05       Impact factor: 24.094

7.  Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization.

Authors:  Cheuk-Man Yu; Li Wang; Elaine Chau; Raymond Hon-Wah Chan; Shun-Ling Kong; Man-Oi Tang; Jill Christensen; Robert W Stadler; Chu-Pak Lau
Journal:  Circulation       Date:  2005-08-01       Impact factor: 29.690

8.  Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure: the COMPASS-HF study.

Authors:  Robert C Bourge; William T Abraham; Philip B Adamson; Mark F Aaron; Juan M Aranda; Anthony Magalski; Michael R Zile; Andrew L Smith; Frank W Smart; Mark A O'Shaughnessy; Mariell L Jessup; Brandon Sparks; David L Naftel; Lynne Warner Stevenson
Journal:  J Am Coll Cardiol       Date:  2008-03-18       Impact factor: 24.094

9.  Intracardiac impedance monitors hemodynamic deterioration in a chronic heart failure pig model.

Authors:  Carsten Stahl; Wolfram Beierlein; Tobias Walker; Andreas Straub; Zolt Nagy; Karolin Knubben; Tim O Greiner; Michael Lippert; Gerald Czygan; Stefan Paule; Oliver Schweika; Volker Kühlkamp
Journal:  J Cardiovasc Electrophysiol       Date:  2007-06-06

10.  Volume catheter parallel conductance varies between end-systole and end-diastole.

Authors:  Chia-Ling Wei; Jonathan W Valvano; Marc D Feldman; Matthias Nahrendorf; Ronald Peshock; John A Pearce
Journal:  IEEE Trans Biomed Eng       Date:  2007-08       Impact factor: 4.538

View more
  1 in total

1.  Smart Drain for Post-Cardiac Surgery Left Ventricular Volumes Evaluated in Large Animal Models.

Authors:  Aleksandra B Gruslova; Andrew G Cabe; Anil Kottam; John Walmsley; John E Porterfield; Edward Y Sako; Marc D Feldman; Jonathan W Valvano
Journal:  Ann Thorac Surg       Date:  2021-12-07       Impact factor: 5.102

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.